Trin Calservices

Brampton, Canada

Visit website
A2LA 5098.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
12
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 5098.01 · 12 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 1 of 11 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 TRIN CALSERVICES INC. 45 Bramalea Road, Suite 204 Brampton, Ontario L6T 2W4 CANADA Steve Ramsumair Phone: +1(905) 794-1878 CALIBRATION Valid To: November 30, 2026 Certificate Number: 5098.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 5 (±) Comments DC Voltage – Generate 3 Measuring Instruments (0 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V 0.04 μV/V + 2.0 μV 22 μV/V + 4.2 μV 0.02 mV/V + 0.04 mV 0.04 mV/V + 0.29 mV 0.04 mV/V + 3.1 mV Fluke 5520A DC Current – Generate3 Measuring Instruments Toroidal & Other Type of Clamps (0 to 330) μA 330 μA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 20) A (20 to 300) A (300 to 600) A (600 to 1000) A 0.30 nA/µA + 41 nA 0.20 µA/mA + 0.1 µA 0.20 µA/mA + 0.51 µA 0.20 µA/mA + 5.1 µA 0.40 mA/A + 0.08 mA 0.56 mA/A + 0.08 mA 2.0 mA/A + 1.0 mA 0.59 % + 0.63 A 0.61 % + 0.58 A 0.61 % + 0.56 A Fluke 5520A Fluke 5520A, 50 turn coil
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 2 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate 3 Measuring Instruments (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω 0.08 mΩ/Ω + 20 mΩ 0.06 mΩ/Ω + 29 mΩ 0.81 mΩ/Ω + 5.2 mΩ Fluke 5520A Resistance – Generate3 Measuring Instruments (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (119 to 330) MΩ (0.33 to 1.1) GΩ 0.06 mΩ/Ω + 40 mΩ 0.06 Ω/kΩ + 0.04 Ω 0.06 Ω/kΩ + 0.40 Ω 0.06 Ω/kΩ + 0.21 Ω 0.06 Ω/kΩ + 2.0 Ω 0.06 Ω/kΩ + 2.0 Ω 0.06 Ω/kΩ + 20 Ω 0.06 kΩ/kΩ + 0.02 kΩ 0.12 kΩ/MΩ + 0.30 kΩ 0.26 kΩ/MΩ + 0.50 kΩ 0.50 kΩ/MΩ + 4.9 kΩ 1.0 kΩ/MΩ + 6.0 kΩ 6.0 kΩ/MΩ + 0.20 MΩ 30 kΩ/MΩ + 1.0 MΩ Fluke 5520A Electrical Simulation of Thermocouple Indicating Systems – Generate & Measure 3 Type C Type E Type J (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.60 °C 0.52 °C 0.62 °C 1.0 °C 1.7 °C 1.0 °C 0.32 °C 0.28 °C 0.32 °C 0.42 °C 0.54 °C 0.32 °C 0.28 °C 0.34 °C 0.46 °C Fluke 5520A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 3 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments Electrical Simulation of Thermocouple Indicating Systems – Generate & Measure 3 (cont) Type K Type N Type R Type S Type T (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.66 °C 0.36 °C 0.32 °C 0.52 °C 0.80 °C 0.82 °C 0.44 °C 0.38 °C 0.36 °C 0.54 °C 1.2 °C 0.71 °C 0.67 °C 0.80 °C 0.96 °C 0.73 °C 0.75 °C 0.93 °C 1.3 °C 0.48 °C 0.32 °C 0.28 °C Fluke 5520A Electrical Simulation of RTD Indicators and Indicating Systems Generate 3 – Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.05 °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C 0.23 °C Fluke 5520A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 4 of 11 Parameter/Range Frequency CMC 2, 5 (±) Comments AC Voltage – Generate3 Measuring Instruments (3 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 10 Hz to 1 kHz (1 to 10) kHz (10 to 50) kHz 10 Hz to 1 kHz (1 to 10) kHz (10 to 50) kHz 10 Hz to 1 kHz (1 to 10) kHz (10 to 50) kHz 10 Hz to 1 kHz (1 to 10) kHz (10 to 50) kHz 10 Hz to 1 kHz (1 to 10) kHz (10 to 50) kHz 10 Hz to 1 kHz (1 to 10) kHz 0.34 μV/mV 0.81 μV/mV 2.4 μV/mV 0.34 μV/mV 0.37 μV/mV 0.75 μV/mV 0.34 mV/V 0.42 mV/V 0.63 mV/V 1.0 mV/V 0.34 mV/V 0.74 mV/V 0.39 mV/V 0.54 mV/V 0.65 mV/V 0.52 mV/V 0.62 mV/V Fluke 5520A AC Current – Generate 3 Measuring Instruments (190 to 329) µA 329 µA to 3.29 mA (3.29 to 32.9) mA 45 Hz to 1 kHz (10 to 30) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 1.8 nA/µA + 0.14 µA 18 nA/µA + 0.45 µA 1.4 µA/mA + 0.26 µA 2.7 µA/mA + 0.72 µA 5.1 µA/mA + 1.4 µA 11 µA/mA + 2.9 µA 0.59 µA/mA + 2.9 µA 0.83 µA/mA + 4.9 µA 1.9 µA/mA + 12 µA 3.9 µA/mA + 25 µA Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 5 of 11 Parameter/Range Frequency CMC 2, 5 (±) Comments AC Current – Generate3 (cont) Measuring Instruments (32.9 to 329) mA (0.33 to 1) A (1 to 3) A (3 to 11) A (11 to 20.5) A Toroidal Type Clamps (20 to 300) A (300 to 600) A (600 to 1000) A Non-Toroidal Type Clamps (20 to 300) A (300 to 600) A (600 to 1000) A 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.66 µA/mA + 0.83 µA 1.2 µA/mA + 34 µA 2.4 µA/mA + 75 µA 4.5 µA/mA + 0.21 mA 0.61 mA/A + 0.25 mA 0.76 mA/A + 1.0 mA 25 mA/A + 5.1 mA 0.86 mA/A + 0.13 mA 6.0 mA/A + 1.0 mA 26 mA/A + 5.1 mA 1.2 mA/A + 2.8 mA 1.2 mA/A + 2.8 mA 1.9 mA/A + 7.0 mA 30 mA/A + 7.1 mA 0.32 % + 0.62 A 0.20 % + 1.0 A 0.35 % + 0.52 A 0.36 % + 0.51 A 0.35 % + 0.50 A 0.34 % + 0.65 A 0.60 % + 0.58 A 0.58 % + 0.68 A 0.61 % + 0.55 A 0.62 % + 0.57 A 0.61 % + 0.57 A 0.60 % + 0.67 A Fluke 5520A Fluke 5520A, 50 turn coil
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 6 of 11 Parameter/Range Frequency CMC 2, 5 (±) Comments Capacitance – Generate3 Measuring Instruments (0.19 to 0.4) nF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 100 Hz 100 Hz 100 Hz 100 Hz 50 Hz, 100 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 10 pF/nF + 20 pF 10 pF/nF + 20 pF 10 pF/nF + 20 pF 5.0 pF/nF + 20 pF 5.0 pF/nF + 0.20 nF 5.0 pF/nF + 0.20 nF 5.0 pF/nF + 0.60 nF 5.0 nF/µF + 2.0 nF 5.0 nF/µF + 6.0 nF 5.0 nF/µF + 20 nF 8.0 nF/µF + 60 nF 9.0 nF/µF + 0.2 µF 9.0 nF/µF + 0.6 µF 9.0 µF/mF + 2.1 µF 9.0 µF/mF + 6.0 µF 9.0 µF/mF + 20 µF 15 µF/mF + 60 µF 22 µF/mF + 0.20 mF Fluke 5520A AC Voltage – Measure 3 Generating Instruments (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 750) V 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 45 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 2.1 mV/V + 0.3 mV 1.7 mV/V + 0.5 mV 2.7 mV/V + 0.8 mV 13 mV/V + 5.0 mV 2.1 mV/V + 3.0 mV 2.4 mV/V + 5.0 mV 3.0 mV/V + 8.0 mV 13 mV/V + 50 mV 1.3 mV/V + 30 mV 7.8 mV/V + 50 mV 3.2 mV/V + 80 mV 1.3 mV/V + 0.23 V 1.8 mV/V + 0.38 V 2.8 mV/V + 0.60 V Keysight 34465A
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 7 of 11 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure 3 (cont) Generating Instruments (0.1 to 25) kV 60 Hz 1.2 V/kV + 0.28 V Keysight 34465A w/80K-40 high voltage probe AC Current – Measure 3 Generating Instruments (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (0.1 to 3) A (3 to 10) A 10 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 10 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 10 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 10 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (1 to 10) kHz 45 Hz to 1 kHz 3.0 µA/mA + 0.4 µA 3.3 µA/mA + 0.4 µA 5.0 µA/mA + 0.4 µA 3.1 µA/mA + 0.4 µA 3.3 µA/mA + 0.4 µA 5.0 µA/mA + 0.4 µA 3.1 µA/mA + 0.4 µA 3.3 µA/mA + 0.4 µA 5.0 µA/mA + 0.4 µA 3.2 mA/A + 0.4 mA 3.3 mA/A + 0.4 mA 13 mA/A + 0.4 mA 3.9 mA/A + 0.4 mA 8.7 mA/A + 0.4 mA 4.6 mA/A + 0.4 mA Keysight 34465A Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Measure 3 Generating Instruments (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 0.07 µV/mV + 5.2 µV 50 µV/V + 7.3 µV 34 µV/V + 23 µV 0.05 mV/V + 0.02 mV 0.05 mV/V + 0.01 mV Keysight 34465A
0.1 to 25 kV
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 8 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Measure 3 (cont) Generating Instruments (1 to 20) kV (20 to 35) kV (35 to 40) kV 1 V/kV + 0.09 V 0.93 V/kV + 1.3 V 0.80 V/kV + 6.0 V Keysight 34465A w/80K-40 high voltage probe DC Current– Measure3 – Generating Instruments (0 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 3) A (3 to 10) A 0.52 nA/µA + 1 nA 69 µA/mA + 0.08 µA 0.50 µA/mA + 2.0 µA 0.51 µA/mA + 5 µA 0.81 mA/A + 0.10 mA 2.0 mA/A + 0.60 mA 1.3 mA/A + 1.0 mA Keysight 34465A Four-Wire Resistance – Measure 3 Generating Instruments (0 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ 0.67 mΩ/Ω + 20 mΩ 0.09 Ω/kΩ + 0.02 Ω 0.49 Ω/kΩ + 0.50 Ω 0.08 Ω/kΩ + 0.84 Ω Keysight 34465A Two-Wire Resistance – Measure 3 Generating Instruments (0 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 0.17 Ω/kΩ + 0.02 Ω 0.08 Ω/kΩ + 0.04 Ω 0.09 Ω/kΩ + 0.61 Ω 0.14 kΩ/MΩ + 0.01 kΩ 0.40 kΩ/MΩ + 0.17 kΩ 3.2 kΩ/MΩ + 1.1 kΩ Keysight 34465A
9ASME B107.300-2010-See scope document
10SAE AMS2750 3.4-32 to 2190 °F
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5098.01) 03/27/2025 Page 11 of 11 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this ca libration. Please note the uncertainties achievable on a customer's site can normally be expected to be la rger than the Calibration and Measurement Capability uncertainty (CMC) that the accredited laboratory has been assigned on the A2LA Scope. Allowance must be made for aspects such as the environment at th e place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the calibration uncertainty being larger than the CMC uncertainty. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.
12

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited TRIN CALSERVICES INC. Brampton, Ontario, CANADA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 27th day of March 2025. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 5098.01 Valid to November 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.