Campbell Scientific (Canada) Corporation
Edmonton, Canada
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Sites in our directory
- 4
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 4227.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4227.01) Revised 10/18/2025 Page 2 of 3
II. Optical Quantities
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Irradiance – Measuring
Equipment
(285 to 3000) nm
Wavelength
>500 W/m
2
Irradiance
0.82 %
1.5 %
1.6 %
MS-80
CMP21
SR30-M2-D1
III. Thermodynamic
Parameter/Equipment
Range
CMC
2, 4 (±)
Comments
Relative Humidity –
at 23 °C
(10 to 80) % RH
0.0072 (% RH/% RH) + 0.23 % RH
Using chilled
mirror
hygrometer
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Frequency –
Measuring Equipment
1 Hz to 300 kHz
29 mHz/kHz + 22 mHz
BK Precision
4054B
Frequency – Measure
40 Hz to 2 kHz
0.056 mHz/Hz + 33 mHz
Keysight 34465A,
Keysight 34410A
___________________________________________
1
This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4227.01) Revised 10/18/2025 Page 3 of 3
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
5 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 4 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.