HELIOS Dr. Horst Schmidt Kliniken Wiesbaden GmbH Institut für Labordiagnostik und Hygiene Bereich Hygiene und Umweltmedizin
Ludwig-Erhard-Straße 90, 65199, Wiesbaden, Germany
- Accredited standards
- 10
- DAKKS certificates
- 3
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 27888Water quality - Determination of electrical conductivity
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
ISO 27888
DIN EN ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11; DIN EN ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11 Pseudomonas aeruginosa DIN EN ISO 16266 2008 -05 ANLAGE 2: CHEMISCHE PARAMETER nicht belegt ANLAGE 3; DIN EN ISO 9308 -1 2017 -09 Eisen nicht belegt Elektrische Leitfähigkeit DIN EN 27888 1993 -11 Färbung nicht belegt Geruch nicht belegt Geschmack nicht belegt Koloniezahl bei 22; ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11; ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11 Pseudomonas aeruginosa DIN EN ISO 16266 2008 -05 ANLAGE 2: CHEMISCHE PARAMETER nicht belegt ANLAGE 3
DIN EN ISO 19458; DIN EN ISO 16266; DIN EN ISO 9308-1; DIN EN ISO 7899-2; ISO 5667-5
DIN EN ISO 19458; DIN EN ISO 11731; DIN EN ISO 6222; ISO 19458; ISO 11731
DIN EN ISO 11731 2019-03; DIN EN ISO 10523; DIN EN ISO 27888; DIN EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18; DIN 38404
DIN EN ISO 10523 2012 -04; DIN EN ISO 11731 2019 -03 UBA Empfehlung 18; ISO 10523 2012 -04; ISO 11731 2019 -03 UBA Empfehlung 18; EN ISO 10523 2012 -04
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
13 lines
ISO/IEC 17025
ActiveD-PL-13015-01-00
ISO/IEC 17025
ActiveD-PL-13015-01-01
ISO/IEC 17025
ActiveD-PL-13015-01-02
Location
Labs with overlapping accredited scope in Germany
- Chemisches und mikrobiologisches Institut UEGWetzlar · ~57 kmDAKKSShares 5 accredited methods and materialsEN ISO 10523EN ISO 11731 2019-03 UBA Empfehlung 18EN ISO 19458
- SchwarzwaldWASSER LaborBühl · ~151 kmDAKKSShares 5 accredited methods and materialsEN ISO 10523EN ISO 11731 2019-03 UBA Empfehlung 18EN ISO 19458
- Verein des Hygiene-Instituts des Ruhrgebiets e.V. Hygiene-Institut des Ruhrgebiets Institut für Umwelthygiene und ToxikologieGelsenkirchen · ~178 kmDAKKSShares 5 accredited methods and materialsEN ISO 10523EN ISO 11731 2019-03 UBA Empfehlung 18EN ISO 19458
- UCL Umwelt Control LaborLünen · ~180 kmDAKKSShares 5 accredited methods and materialsEN ISO 10523EN ISO 11731 2019-03 UBA Empfehlung 18EN ISO 19458
- GWA Gesellschaft für Wasser- und Abwasserservice mbH Institut für Wasser- und UmweltanalytikLuisenthal · ~196 kmDAKKSShares 5 accredited methods and materialsEN ISO 10523EN ISO 11731 2019-03 UBA Empfehlung 18EN ISO 19458
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.