A.R. Services
Grimsby, Canada
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Sites in our directory
- 4
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2823.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | See scope document |
| 2 | - | Thermocouple Devices (Type E, J, K, N, R, S, T); RTD Devices; Temperature Sensors3, 4 – Types RTD & T/C Types J, K, T; Relative Humidity3 – Measuring EquipmentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2823.01) Revised 04/30/2026 Page 2 of 3
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature3, 4 – Instruments
(Electrical Simulation) –
Thermocouple Devices (Type
E, J, K, N, R, S, T)
(-100 to 1500) °C
0.61 °C
Multifunction calibrator
Temperature3 – Instruments
(Electrical Simulation) –
RTD Devices
(-180 to 316) °C
0.03 °C
Multifunction calibrator
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Temperature Sensors3, 4 –
Types RTD & T/C Types J,
K, T
(-80 to 232) °C
0.3 °C
Hart 1502A/Pt100 (385)
readout & temperature
probe
Relative Humidity3 –
Measuring Equipment
Measure
(Chambers)
(11 to 89) % RH
(89 to 90) % RH
(11 to 89) % RH
(89 to 90) % RH
2.0 % RH
2.8 % RH
2.0 % RH
2.8 % RH
Humidity chamber and
Vaisala humidity probe
& readout
Vaisala humidity probe
& readout
____________________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | -100 to 1500 °C |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2823.01) Revised 04/30/2026 Page 3 of 3
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects suc h as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The CMC stated is for one or more of the thermocouple types that the calibrator is capable of performing.
See measurement uncertainty budgets for the “CMC” for a specific thermocouple type. It is also important
to note that the “CMC” stated on each calib ration certificate, reflects the applicable uncertainty for the
customer’s thermocouple type.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.