Bobier Metrology Solutions

G-4163 Corunna Road, 48532, Flint, MI, United States

Visit website
A2LA 1526.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 1526.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017-to 118 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1526.01) 11/7/2024 Page 2 of 3 Parameter/Equipment Range CMC2 (±) Comments Calipers Up to 12 in Up to 304.8 mm 89 µin + 2.1 µin/in 2.3 µm + 0.0021 µm/mm Master block Master gage Micrometers Up to 4 in Up to 101.6 mm 54 µin + 10 µin/in 1.4 µm + 0.010 µm/mm Master block Master gage Depth Micrometers Up to 1 in Up to 25.4 mm 56 µin + 3.6 µin/in 1.4 µm + 0.0036 µm/mm Master block Ring Gage – Inside Diameter Up to 12 in Up to 304.8 mm 2.3 μin + 11 μin/in 0.06 µm + 0.011 µm/mm Leitz PMM 654 CMM, master ring Plug Gage – Outside Diameter Up to 12 in Up to 304.8mm 15 µin + 1 µin/in 0.38 µm + 0.001 µm/mm Leitz PMM 654 CMM, master plug, laser micrometer Gage Balls/CMM Cal Spheres Up to 2 in Up to 50.8 mm 29 µin + 10 µin/in 0.74 µm + 0.010 µm/mm Leitz PMM 654 CMM Surface Finish (Ra & Rz) Up to 4.7 in Up to 120 mm 2.1 µin (Ra & Rz) 0.05 µm (Ra & Rz) Mahr PGK120 II. Dimensional Testing/Calibration3 Parameter/Equipment Range CMC2 (±) Comments Linear Accuracy – 2D 3D Position Up to 24 in Up to 609.6 mm Up to 24 in Up to 609.6 mm 28 x 40 x 24 in 711.2 × 1016 × 609.6 mm 3.5 µin + 11 µin/in 0.09 µm + 0.011 µm/mm 17 µin + 32 µin/in 0.43 µm + 0.032 µm/mm 7.9 µin + 33 µin/in 0.20 µm + 0.033 µm/mm CMM, optical ____________________________________________
to 304.8 mm
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1526.01) 11/7/2024 Page 3 of 3 1 This laboratory offers commercial calibration service and dimensional testing service. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above. Accredited test reports issued containing appropriate statements of measurement results, measurement uncertainty, and traceability are considered equivalent to a “calibration” certificate. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
4ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

G-4163 Corunna Road, Flint, MI, 48532, US

43.01617, -83.69002

Open in Maps

Accreditation data refreshed from the A2LA register on .