A2LA certificate 2167.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2167.01) 5/28/2024 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
PRODUCTION SERVICE CO.
16025 Brookpark Road
Cleveland, OH 44142
Ed Sinegar Phone: 216 362 6100
CALIBRATION
Valid To: March 31, 2026 Certificate Number: 2167.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations
1, 5:
I. Dimensional
Parameter/Equipment Range CMC
2, 4 (±)
Comments
Optical Comparators3 –
Length of Travel
Magnification, 10x to 100x
Angle
Up to 24 in
Up to 12 in
Up to 360°
(220 + 11L) µin
220 µin
0.027°
Glass grid and
glass scale
Video Measuring Machines3 –
Length of Travel (X-Y Axis)
Length of Travel (Z Axis)
Angle
Up to 24 in
Up to 4 in
Up to 360°
(220 + 11L) µin
(270 + 4L) µin
0.027°
Glass grid
Step gage
___________________________________________
1 This laboratory offers commercial and field calibration service. | to 24 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2167.01) 5/28/2024 Page 2 of 2
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards o r nearly ideal measuring equipment. CMCs
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually
using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration
performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device
and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.