FindTestingLabs
Registers refreshed 2026-10-25.See refresh dates
Poland

STAL-TECH NDT

ul. Żwirki i Wigury 6, 38-400, Krosno, Poland

PCA AB 1969ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
7
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 7 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 3452-1Non-destructive testing - Penetrant testing - Part 1: General principles
ISO 3452-6Non-destructive testing - Penetrant testing - Part 6: Penetrant testing at temperatures lower than 10 degrees C
ISO 16809Non-destructive testing - Ultrasonic thickness determination
ISO 17636-1Non-destructive testing of welds - Radiographic testing - Part 1: X- and gamma-ray techniques with film
ISO 17637Non-destructive testing of welds - Visual testing of fusion-welded joints
ISO 17638Non-destructive testing of welds - Magnetic particle testing
ISO 17640Non-destructive testing of welds - Ultrasonic testing - Techniques, testing levels, and assessment

Read from the PCA scope document we downloaded on 2026-08-05. Register refreshed 2026-10-23.

Scope as published by PCA

3 lines
PCA

ISO/IEC 17025

Active

AB 1969

The scope document we hold says it is valid until 2030-06-02.

View on PCA

Accredited scope, certificate AB 1969

LineMethodMatrixRange
1-wyrobów i materiałów konstrukcyjnych
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1969 Scope of accreditation No. AB 1969 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1969 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 1 z/of 03.06.2026 KIEROWNIK BIURA DS. AKREDYTACJI TADEUSZ MATRAS Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1969 z dnia 03.06.2026 r. Cykl akredytacji od 03.06.2026 r. do 02.06.2030 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No. AB 1969 of 03.06.2030 Accreditation cycle from 03.06.2026 to 02.06.2030 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 1, 03.06.2026 1/3 Nazwa i adres / Name and address STAL-TECH NDT Sp. z o.o. ul. Żwirki i Wigury 6 38-400 Krosno Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - L/8 - Badania nieniszczące wyrobów i materiałów konstrukcyjnych / Non-destructive tests of construction products and materials Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 1969
-
2PN-EN ISO 17637:2017-02; PN-EN ISO 3452-1:2021-12; PN-EN ISO 3452-6:2009; PN-EN ISO 17640:2019-01; PN-EN ISO 17636-1:2023-02; PN-EN ISO 17638:2017-01; PN-EN ISO 16809:2025-12Złącza spawane wyrobów i materiałów metalowych; Wyroby i materiały metalowe ferromagnetycznych; Wyroby i materiały metalowe2 to 100 mm
3

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1969 Zatwierdzam status zmian KIEROWNIK BIURA DS. AKREDYTACJI TADEUSZ MATRAS dnia: 03.06 .2026 r. Wydanie nr 1, 03.06.2026 r. 3/3 HOLOGRAM HOLOGRAM HOLOGRAM HOLOGRAM Wykaz zmian Zakresu Akredytacji Nr AB 1969 Status zmian: wersja pierwotna – A

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Żwirki i Wigury 6, Krosno, 38-400, PL

49.69380, 21.76515

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.