CIRCUTOR, S.A. (Unipersonal)
C/ Vial Sant Jordi, s/n, 08232, Viladecavalls, Spain
Visit website- Accredited standards
- 17
- ENAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ENAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 17 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series11
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-34
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 60068 series3
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
Other standards3
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-030
UNE-EN 61000-4-2; IEC-61000-4-2; UNE-EN 61000-4-4; IEC-61000-4-4; UNE-EN 61000-4-5; IEC-61000-4-5
UNE-EN 61000-4-6; IEC-61000-4-6; UNE-EN 61000-4-8; IEC-61000-4-8; UNE-EN 61000-4-11; IEC-61000-4-11; UNE-EN 61000-6-3; IEC-61000-6-3; UNE-EN 61000-6-4; IEC-61000-6-4; UNE-EN 55016-2-1; CISPR 16-2-1
UNE-EN 61000-4-34; IEC 61000-4-34; UNE-EN 61000-6-1; IEC-61000-6-1; UNE-EN 61000-6-2; IEC-61000-6-2
UNE-EN 60068-2-1; IEC 60068-2-1; UNE-EN 60068-2-2; IEC 60068-2-2; UNE-EN 60068-2-78; IEC 60068-2-78
UNE-EN 61010-1; IEC-61010-1; UNE-EN 61010-2-030; IEC-61010-2-030
Read from the scope as published by ENAC. Register refreshed 2026-10-10.
Scope as published by ENAC
5 lines
ISO/IEC 17025
Active1370/LE2532
Accredited scope, certificate 1370/LE2532
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNE-EN 61000-4-2; IEC-61000-4-2; UNE-EN 61000-4-4; IEC-61000-4-4; UNE-EN 61000-4-5; IEC-61000-4-5 | Equipos eléctricos y electrónicos | - |
| 2 | UNE-EN 61000-4-6; IEC-61000-4-6; UNE-EN 61000-4-8; IEC-61000-4-8; UNE-EN 61000-4-11; IEC-61000-4-11; UNE-EN 61000-6-3; IEC-61000-6-3; UNE-EN 61000-6-4; IEC-61000-6-4; UNE-EN 55016-2-1; CISPR 16-2-1 | Equipos eléctricos y electrónicos para entorno doméstico, residencial, comercial e industria ligera; Equipos eléctricos y electrónicos para entorno industrial; Aparatos de medida eléctricos y electrónicos | to 300 A/m |
| 3 | UNE-EN 61000-4-34; IEC 61000-4-34; UNE-EN 61000-6-1; IEC-61000-6-1; UNE-EN 61000-6-2; IEC-61000-6-2 | Electrical and electronic equipment for residential, commercial and light-industrial environments; Electrical and electronic equipment for industrial environments | - |
| 4 | UNE-EN 61010-1; IEC-61010-1; UNE-EN 61010-2-030; IEC-61010-2-030 | Electrical equipment for measurement, control and laboratory use | - |
| 5 | UNE-EN 60068-2-1; IEC 60068-2-1; UNE-EN 60068-2-2; IEC 60068-2-2; UNE-EN 60068-2-78; IEC 60068-2-78 | Aparatos y dispositivos eléctricos, electrónicos, electromecánicos y sus componentes; Electrical, electronic, electromechanical or mechanical systems and devices and its components | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.