MR COMP
Buschgrundstraße 33, 45894, Gelsenkirchen, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at MR COMP?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-13383-01-01Active
- D-PL-13383-01-00Active
Accredited standards
7Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ASTM F640Name not checked yet
DIN 13273-7; ISO/TS 10974 : 2018-04 Assessment of the safety of Magnetic Resonance Imaging for Patients with an active implantable medical device IEC 62570 : 2014-02 Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment ASTM F640; IEC 62570; ASTM F640; ASTM F2119
ASTM F640; ASTM F2119; DIN 13273-7; ISO/TS 10974; IEC 62570; ASTM F2052; ASTM F2182; ASTM F2213; ASTM F2503
ASTM F2052Name not checked yet
ISO/TS 10974 - Measurement of high frequency Induced Heating ASTM F2182 - Measurement of Gradient Induced Heating - Measurement of Gradient Induced Vibrations - Measurement of Gradient Induced Displacement Force ASTM F2052 - Measurement of magnetic Induced Torque ASTM F2213 - Measurement of Gradient Induced Electrical Potential - Measurement of magnetic Induced Malfunction - Measurement of high frequency Induced Malfunction - Measurement of Gradient Induced Malfunction - Measurement of Combined MR Field Effects - MR Conformity Mark Determination Also applicable: IEC 62570 ASTM F2503; IEC 62570; ASTM F2182; ASTM F2052; ASTM F2213
ISO/TS 10974; ASTM F2182; ASTM F2052; ASTM F2213; IEC 62570; ASTM F2503
ASTM F640; ASTM F2119; DIN 13273-7; ISO/TS 10974; IEC 62570; ASTM F2052; ASTM F2182; ASTM F2213; ASTM F2503
ASTM F2119Name not checked yet
DIN 13273-7; ISO/TS 10974 : 2018-04 Assessment of the safety of Magnetic Resonance Imaging for Patients with an active implantable medical device IEC 62570 : 2014-02 Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment ASTM F640; IEC 62570; ASTM F640; ASTM F2119
ASTM F640; ASTM F2119; DIN 13273-7; ISO/TS 10974; IEC 62570; ASTM F2052; ASTM F2182; ASTM F2213; ASTM F2503
ASTM F2182Name not checked yet
ISO/TS 10974 - Measurement of high frequency Induced Heating ASTM F2182 - Measurement of Gradient Induced Heating - Measurement of Gradient Induced Vibrations - Measurement of Gradient Induced Displacement Force ASTM F2052 - Measurement of magnetic Induced Torque ASTM F2213 - Measurement of Gradient Induced Electrical Potential - Measurement of magnetic Induced Malfunction - Measurement of high frequency Induced Malfunction - Measurement of Gradient Induced Malfunction - Measurement of Combined MR Field Effects - MR Conformity Mark Determination Also applicable: IEC 62570 ASTM F2503; IEC 62570; ASTM F2182; ASTM F2052; ASTM F2213
ISO/TS 10974; ASTM F2182; ASTM F2052; ASTM F2213; IEC 62570; ASTM F2503
ASTM F640; ASTM F2119; DIN 13273-7; ISO/TS 10974; IEC 62570; ASTM F2052; ASTM F2182; ASTM F2213; ASTM F2503
ASTM F2213Name not checked yet
ISO/TS 10974 - Measurement of high frequency Induced Heating ASTM F2182 - Measurement of Gradient Induced Heating - Measurement of Gradient Induced Vibrations - Measurement of Gradient Induced Displacement Force ASTM F2052 - Measurement of magnetic Induced Torque ASTM F2213 - Measurement of Gradient Induced Electrical Potential - Measurement of magnetic Induced Malfunction - Measurement of high frequency Induced Malfunction - Measurement of Gradient Induced Malfunction - Measurement of Combined MR Field Effects - MR Conformity Mark Determination Also applicable: IEC 62570 ASTM F2503; IEC 62570; ASTM F2182; ASTM F2052; ASTM F2213
ISO/TS 10974; ASTM F2182; ASTM F2052; ASTM F2213; IEC 62570; ASTM F2503
ASTM F640; ASTM F2119; DIN 13273-7; ISO/TS 10974; IEC 62570; ASTM F2052; ASTM F2182; ASTM F2213; ASTM F2503
ASTM F2503Name not checked yet
ISO/TS 10974 - Measurement of high frequency Induced Heating ASTM F2182 - Measurement of Gradient Induced Heating - Measurement of Gradient Induced Vibrations - Measurement of Gradient Induced Displacement Force ASTM F2052 - Measurement of magnetic Induced Torque ASTM F2213 - Measurement of Gradient Induced Electrical Potential - Measurement of magnetic Induced Malfunction - Measurement of high frequency Induced Malfunction - Measurement of Gradient Induced Malfunction - Measurement of Combined MR Field Effects - MR Conformity Mark Determination Also applicable: IEC 62570 ASTM F2503; IEC 62570; ASTM F2182; ASTM F2052; ASTM F2213
ISO/TS 10974; ASTM F2182; ASTM F2052; ASTM F2213; IEC 62570; ASTM F2503
ASTM F640; ASTM F2119; DIN 13273-7; ISO/TS 10974; IEC 62570; ASTM F2052; ASTM F2182; ASTM F2213; ASTM F2503
IEC 62570Name not checked yet
ISO/TS 10974 - Measurement of high frequency Induced Heating ASTM F2182 - Measurement of Gradient Induced Heating - Measurement of Gradient Induced Vibrations - Measurement of Gradient Induced Displacement Force ASTM F2052 - Measurement of magnetic Induced Torque ASTM F2213 - Measurement of Gradient Induced Electrical Potential - Measurement of magnetic Induced Malfunction - Measurement of high frequency Induced Malfunction - Measurement of Gradient Induced Malfunction - Measurement of Combined MR Field Effects - MR Conformity Mark Determination Also applicable: IEC 62570 ASTM F2503; IEC 62570; ASTM F2182; ASTM F2052; ASTM F2213
DIN 13273-7; ISO/TS 10974 : 2018-04 Assessment of the safety of Magnetic Resonance Imaging for Patients with an active implantable medical device IEC 62570 : 2014-02 Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment ASTM F640; IEC 62570; ASTM F640; ASTM F2119
ISO/TS 10974; ASTM F2182; ASTM F2052; ASTM F2213; IEC 62570; ASTM F2503
ASTM F640; ASTM F2119; DIN 13273-7; ISO/TS 10974; IEC 62570; ASTM F2052; ASTM F2182; ASTM F2213; ASTM F2503
Scope as published by DAKKS
7 lines
ISO/IEC 17025
ActiveD-PL-13383-01-01
Accredited scope, certificate D-PL-13383-01-01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | dimensional | DIN EN ISO/IEC 17025:2018 | medical devices; implants | - |
| 2 | physical | ISO/TS 10974; ASTM F2182; ASTM F2052; ASTM F2213; IEC 62570; ASTM F2503 | Medical devices and implants | - |
| 3 | materials | ASTM F640; ASTM F2119; DIN 13273-7; ISO/TS 10974; IEC 62570; ASTM F2052; ASTM F2182; ASTM F2213; ASTM F2503 | Medical devices and implants; Catheter | - |
| 4 | - | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-13383-01-00
Accredited scope, certificate D-PL-13383-01-00
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | mechanical | DIN EN ISO/IEC 17025:2018 | medical devices and implants | - |
| 2 | mechanical | ISO/TS 10974 - Measurement of high frequency Induced Heating ASTM F2182 - Measurement of Gradient Induced Heating - Measurement of Gradient Induced Vibrations - Measurement of Gradient Induced Displacement Force ASTM F2052 - Measurement of magnetic Induced Torque ASTM F2213 - Measurement of Gradient Induced Electrical Potential - Measurement of magnetic Induced Malfunction - Measurement of high frequency Induced Malfunction - Measurement of Gradient Induced Malfunction - Measurement of Combined MR Field Effects - MR Conformity Mark Determination Also applicable: IEC 62570 ASTM F2503; IEC 62570; ASTM F2182; ASTM F2052; ASTM F2213 | Medical devices and implants | - |
| 3 | mechanical | DIN 13273-7; ISO/TS 10974 : 2018-04 Assessment of the safety of Magnetic Resonance Imaging for Patients with an active implantable medical device IEC 62570 : 2014-02 Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment ASTM F640; IEC 62570; ASTM F640; ASTM F2119 | Medical devices and implants; Catheter | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.