JMS SOUTHEAST
105 TEMPERATURE LANE, 28677, STATESVILLE, NC, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 7272.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7272.01) 12/08/2025 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
JMS SOUTHEAST INC
105 Temperature Lane
Statesville, NC 28677
Malachi Vang Phone: 704 873 1835
CALIBRATION
Valid To: January 31, 2028 Certificate Number: 7272.01
In recognition of the successful completion of the A2LA evaluation process, (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements),
accreditation is granted to this laboratory to perform the following calibrations
1, 3:
I. Thermodynamics
Parameter/Equipment
Range
CMC2 (±) Comments
Thermocouple –
Type B
Type C
Type E
(>800 to 1100) °C
(>1100 to 1200) °C
(>1200 to 1300) °C
(>1300 to 1400) °C
(>1400 to 1500) °C
(>1500 to 1600) °C
(>1600 to 1700) °C
(>0 to 400) °C
(>400 to 661) °C
(>661 to 1100) °C
(>1100 to 1200) °C
(>1200 to 1300) °C
(>1300 to 1400) °C
(>1400 to 1500) °C
(>1500 to 1600) °C
(>1600 to 1700) °C
-196 °C
(>-80 to 0) °C
(>0 to 400) °C
(>400 to 661) °C
(>661 to 870) °C
0.95 °C
1.3 °C
1.8 °C
2.3 °C
2.7 °C
3.3 °C
3.6 °C
0.11 °C
0.092 °C
0.31 °C
1.3 °C
1.8 °C
2.3 °C
2.7 °C
3.3 °C
3.6 °C
0.24 °C
0.12 °C
0.11 °C
0.092 °C
0.31 °C
For temperatures below
0 °C, comparison to an
SPRT reference is
performed.
For temperatures above
0 °C to 1450 °C,
comparison to a
Primary Type S or
Type B thermocouple is
performed.
For temperatures above
1450 °C, a comparison
to a Primary Type B
thermocouple is
performed. | to 1700 °C |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7272.01) 12/08/2025 Page 2 of 3
Parameter/Equipment
Range CMC2 (±) Comments
Thermocouples – (cont)
Type J
Type K
Type N
Type R
Type S
Type T
(>0 to 400) °C
(>400 to 661) °C
(>661 to 760) °C
-196 °C
(>-80 to 0) °C
(>0 to 400) °C
(>400 to 661) °C
(>661 to 1100) °C
(>1100 to 1200) °C
(>1200 to 1260) °C
-196 °C
(>-80 to 0) °C
(>0 to 400) °C
(>400 to 661) °C
(>661 to 1100) °C
(>1100 to 1200) °C
(>1200 to 1260) °C
(>0 to 400) °C
(>400 to 661) °C
(>661 to 1100) °C
(>1100 to 1200) °C
(>1200 to 1300) °C
(>1300 to 1400) °C
(>1400 to 1450) °C
(>0 to 400) °C
(>400 to 661) °C
(>661 to 1100) °C
(>1100 to 1200) °C
(>1200 to 1300) °C
(>1300 to 1400) °C
(>1400 to 1450) °C
-196 °C
(>-80 to 0) °C
(>0 to 400) °C
0.11 °C
0.092 °C
0.31 °C
0.24 °C
0.12 °C
0.11 °C
0.092 °C
0.31 °C
1.3 °C
1.8 °C
0.24 °C
0.12 °C
0.11 °C
0.092 °C
0.31 °C
1.3 °C
1.8 °C
0.11 °C
0.092 °C
0.31 °C
1.3 °C
1.8 °C
2.3 °C
2.7 °C
0.11 °C
0.092 °C
0.31 °C
1.3 °C
1.8 °C
2.3 °C
2.7 °C
0.24 °C
0.12 °C
0.11 °C
For temperatures below
0 °C, comparison to an
SPRT reference is
performed.
For temperatures above
0 °C to 1450 °C,
comparison to a
Primary Type S or
Type B thermocouple is
performed.
For temperatures above
1450 °C, a comparison
to a Primary Type B
thermocouple is
performed. | to 1450 °C |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7272.01) 12/08/2025 Page 3 of 3
Parameter/Equipment
Range CMC2 (±) Comments
RTDs
0 °C
0.01 °C
-196 °C
(>-80 to 100) °C
(>100 to 400) °C
(>400 to 661) °C
0.0067 °C
0.004 °C
0.017 °C
0.018 °C
0.029 °C
0.043 °C
By comparison
Ice bath
TPW
SPRT reference
___________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.