Registers refreshed 2026-11-08.See refresh dates
United Kingdom

Severn Trent Water

Bridgend Science Park, 2 Technology Drive, Bridgend, CF31 3NA, Mid-Glamorgan, United Kingdom

Visit website
UKAS 1229ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
13
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 13 scope lines.

UKAS certificate 1229 · 13 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017Water; water-
2ISO/IEC 17025:2017Water; water-
3ISO/IEC 17025:2017; Standing Committee of Analysts Methods for the Examination of Waters and Associated Materials, HMSO PublicationDrinking water-
4ISO/IEC 17025:2017Water-
5ISO/IEC 17025:2017Water; water-
6ISO/IEC 17025:2017; Microbiology of Drinking Water part 11 2014Drinking water-
7ISO/IEC 17025:2017Water; metals-
8ISO/IEC 17025:2017Water; water-
9-Water; water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

1229 Accredited to ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK Severn Trent Water Limited Issue No: 113 Issue date: 17 October 2025 Testing performed by the Organisation at the locations specified Assessment Manager: LM8 Page 9 of 13 Materials/Products tested Type of test/Properties measured/Range of measurement Standard specifications/ Equipment/Techniques used Location Code WATERS (cont’d) Chemical Tests (cont’d) Potable, Raw, Surface and Groundwaters, Bottled water (Emergency Water, bought in) Turbidity Method 71008 using a manual turbidity meter and robotic determination B Potable, Raw, Surface and Groundwaters Organic Carbon/Non Purgeable Organic Carbon Method 71010 using combustion and NDIR gas analysis B Potable, Raw, Surface and Groundwaters, Bottled water (Emergency Water, bought in) Colour Method 71006 visible spectrometry and robotic determination B Potable, Raw, Surface and Groundwaters UV absorbance and % transmission Method 71014 using spectrometry B Potable, Raw, Surface and Groundwaters, Bottled water (Emergency Water, bought in) pH Electrical Conductivity Turbidity Colour Method 76017 using Skalar automated robot B
-
10ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; In-house method 21032; In-house method 21031; In-house method 21038Drinking water-
11ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; isolation methods: 21030 21031 21032; IEC 17025; In-house method 30001; In-house method 21092Drinking water-
12ISO/IEC 17025:2017Water; WATER; water-
13ISO/IEC 17025 & DWTS - The Water Supply (Water Quality) Regulations 2016 (SI 2016/614) as amendedWaterto 0.3 µg/l

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Bridgend Science Park, 2 Technology Drive, Bridgend, Mid-Glamorgan, CF31 3NA, GB

51.49320, -3.58088

Open in Maps

Accreditation data refreshed from the UKAS register on .