AmSpec Canada Services
9430 Rue Pascal-Gagnon Canada, Saint-Léonard, QC H1P 1Z7, Canada, Saint-Léonard, Canada
Visit website- Accredited standards
- 14
- A2LA certificate
- 1
- Sites in our directory
- 9
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM14
ASTM D56
ASTM D93Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
ASTM D482
ASTM D664
ASTM D974
ASTM D2624
ASTM D3227
ASTM D3241
ASTM D3242
ASTM D4294
ASTM D4814
ASTM D5191
ASTM D5453
ASTM D6079
ASTM D4814; ASTM D2624; ASTM D6079; ASTM D56; ASTM D93
ASTM D974; ASTM D664; ASTM D3242; ASTM D4814; ASTM D482
ASTM D4294; ASTM D3241; ASTM D3227; ASTM D5453; ASTM D5191
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active4139.09
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 4139.09
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM D974; ASTM D664; ASTM D3242; ASTM D4814; ASTM D482 | Oil | - |
| 2 | ASTM D4814; ASTM D2624; ASTM D6079; ASTM D56; ASTM D93 | Water; Petroleum; Fuels | - |
| 3 | ASTM D4294; ASTM D3241; ASTM D3227; ASTM D5453; ASTM D5191 | Water; Sediment; Oils | - |
| 4 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
9430 Rue Pascal-Gagnon Canada, Saint-Léonard, QC H1P 1Z7, Canada, Saint-Léonard, CA
45.58671, -73.59695
Open in MapsOther Locations
8 other sites in this organization
Labs with overlapping accredited scope in Canada
- AGAT LaboratoriesCalgaryA2LAShares 1 accredited test methodASTM D93
- ALS OIL & LUBRICANTS (TRIBOLOGY)BurlingtonA2LAShares 1 accredited materialOil
- ALS OIL & LUBRICANTS (TRIBOLOGY)EdmontonA2LAShares 1 accredited materialOil
- Dell Tech Laboratories Ltd.LondonA2LAShares 1 accredited test methodASTM D93
- Element Materials Technology CanadaEDMONTONA2LAShares 1 accredited test methodASTM D93
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.