MedTech Testing Solution Co.,
9F., No.657-7, Zhongzheng Rd., Xinzhuang Dist., New Taipei City, 24243, Republic of China Taiwan, New Taipei City, Taiwan
A2LA|7331.01ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
7
Locations
1
Contact this laboratory
Register record
- A2LACollected
- 7331.01Active
Certificates and scope
1A2LA
ISO/IEC 17025
Active7331.01
Accredited scope, certificate 7331.01
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| electrical | ISO 10079-1; EN ISO 10079-1; BS EN ISO 10079-1; CAN/CSA ISO 10079-1; ISO 10079-2; EN ISO 10079-2; BS EN ISO 10079-2; CSA ISO 10079-2; ISO 10079-3; EN ISO 10079-3; BS EN ISO 10079-3; CSA ISO 10079-3; ISO 10079-4; EN ISO 10079-4; BS EN ISO 10079-4; IEC 62304; EN 62304; BS EN 62304; CAN/CSA CEI/IEC 62304; JIS T 2304; ANSI AAMI IEC 62304; IEC 61010-1; EN 61010-1; BS EN 61010-1; ANSI/UL 61010-1; CAN/CSA C22.2 No. 61010-1; JIS C 1010-1; IEC 61010-2-010; EN IEC 61010-2-010; BS EN IEC 61010-2-010; ANSI/UL 61010-2-010; CAN/CSA C22.2 No. 61010-2-010; IEC 61010-2-040; EN IEC 61010-2-040; BS EN IEC 61010-2-040; CAN/CSA C22.2 NO.61010-2-040; ANSI/UL 61010-2-040; IEC 61010-2-051; EN IEC 61010-2-051; BS EN IEC 61010-2-051; ANSI/UL 61010-2-051; CAN/CSA C22.2 No. 61010-2-051 | - | - |
| electrical | IEC 60601-1-12; EN 60601-1-12; BS EN 60601-1-12; CAN/CSA C22.2 No. 60601-1-12; AS IEC 60601.1.12; ANSI AAMI IEC 60601-1-12; IEC 60601-2-2; EN IEC 60601-2-2; BS EN IEC 60601-2-2; CAN/CSA C22.2 No. 60601-2-2; AS/NZS IEC 60601.2.2; JIS T 0601-2-2; ANSI AAMI IEC 60601-2-2; IEC 60601-2-3; EN 60601-2-3; BS EN 60601-2-3; CAN/CSA C22.2 No. 60601-2-3; AS 60601.2.3; JIS T 0601-2-3; IEC 60601-2-5; EN 60601-2-5; BS EN 60601-2-5; CAN/CSA C22.2 No. 60601-2-5; AS 60601.2.5; IEC 60601-2-10; EN 60601-2-10; BS EN 60601-2-10; CAN/CSA-C22.2 No. 60601-2-10; AS 60601.2.10; AAMI NS4; IEC 60601-2-18; EN 60601-2-18; BS EN 60601-2-18; CAN/CSA C22.2 No. 60601-2-18; AS/NZS IEC 60601.2.18; JIS T 0601-2-18; IEC 60601-2-22; EN IEC 60601-2-22; BS EN IEC 60601-2-22; CAN/CSA C22.2 No. 60601-2-22; AS IEC 60601.2.22 | Medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment; High frequency surgical equipment and high frequency surgical accessories; Short-wave therapy equipment; Ultrasonic physiotherapy equipment; Transcutaneous electrical nerve stimulators; Endoscopic equipment; Surgical, cosmetic, therapeutic and diagnostic laser equipment | - |
| electrical | - | - | - |
| electrical | IEC 60601-1; EN 60601-1; BS EN 60601-1; ANSI/AAMI ES60601-1; CAN/CSA-C22.2 NO. 60601-1; AS/NZS IEC 60601.1; JIS T 0601-1; IEC 60601-1-6; EN 60601-1-6; BS EN 60601-1-6; CAN/CSA-C22.2 No 60601-1-6; AS IEC 60601.1.6; JIS T 60601-1-6; IEC 60601-1-8; EN 60601-1-8; BS EN 60601-1-8; CAN/CSA-C22.2 No. 60601-1-8; AS IEC 60601.1.8; JIS T 60601-1-8; ANSI AAMI IEC 60601-1-8; IEC 60601-1-11; EN 60601-1-11; BS EN 60601-1-11; ANSI/AAMI HA 60601-1-11; CAN/CSA C22.2 No. 60601-1-11 | Medical electrical equipment; medical electrical systems | - |
| electrical | IEC 61010-2-081; EN IEC 61010-2-081; BS EN IEC 61010-2-081; ANSI/UL 61010-2-081; CAN/CSA C22.2 No. 61010-2-081; IEC 61010-2-101; EN IEC 61010-2-101; BS EN IEC 61010-2-101; ANSI/UL 61010-2-101; CAN/CSA C22.2 No. 61010-2-101; JIS C 1010-2-101 | - | - |
| electrical | IEC 60601-2-62; EN 60601-2-62; BS EN 60601-2-62; AS/NZS IEC 60601.2.62; CAN/CSA C22.2 No. 60601-2-62; IEC 80601-2-30; EN IEC 80601-2-30; BS EN IEC 80601-2-30; CAN/CSA C22.2 No. 80601-2-30; IEC 80601-2-49; EN IEC 80601-2-49; BS EN IEC 80601-2-49; CAN/CSA C22.2 No. 80601-2-49; IEC 80601-2-60; EN IEC 80601-2-60; BS EN IEC 80601-2-60; CAN/CSA C22.2 No. 80601-2-60; IEC 80601-2-77; EN IEC 80601-2-77; BS EN IEC 80601-2-77; CSA C22.2 No. 80601-2-77; ANSI AAMI IEC 80601-2-77; IEC 80601-2-78; EN IEC 80601-2-78; BS EN IEC 80601-2-78; CSA C22.2 No. 80601-2-78; ISO 80601-2-61; EN ISO 80601-2-61; BS EN ISO 80601-2-61; CAN/CSA C22.2 No. 80601-2-61; JIS T 80601-2-61; ISO 27427; EN ISO 27427; BS EN ISO 27427; CAN/CSA ISO 27427; EN 13544-1; BS EN 13544-1; ISO 15197; EN ISO 15197; CAN/CSA ISO 15197 | - | - |
| electrical | IEC 60601-2-25; EN 60601-2-25; BS EN 60601-2-25; CAN/CSA C22.2 No. 60601-2-25; AS/NZS IEC 60601.2.25; JIS T 0601-2-25; ANSI AAMI IEC 60601-2-25; IEC 60601-2-27; EN 60601-2-27; BS EN 60601-2-27; CAN/CSA C22.2 No. 60601-2-27; AS/NZS IEC 60601.2.27; ANSI AAMI IEC 60601-2-27; IEC 60601-2-37; EN 60601-2-37; BS EN 60601-2-37; CAN/CSA C22.2 No. 60601-2-37; JIS T 0601-2-37; IEC 60601-2-39; EN IEC 60601-2-39; BS EN IEC 60601-2-39; CAN/CSA C22.2 No. 60601-2-39; AS/NZS IEC 60601.2.39; JIS T 0601-2-39; IEC 60601-2-41; EN IEC 60601-2-41; BS EN IEC 60601-2-41; AS/NZS IEC 60601.2.41; IEC 60601-2-46; EN IEC 60601-2-46; BS EN IEC 60601-2-46; CAN/CSA C22.2 No. 60601-2-46; AS/NZS 60601.2.46; IEC 60601-2-47; EN 60601-2-47; BS EN 60601-2-47; CAN/CSA C22.2 No. 60601-2-47; IEC 60601-2-57; EN 60601-2-57; BS EN 60601-2-57; CAN/CSA C22.2 No. 60601-2-57; AS IEC 60601.2.57 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.