Techtronic Industries Cordless GP

315 Power Drive, 29621, Anderson, SC, United States

A2LA 5918.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
17
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 5918.01 · 17 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 1 of 16 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 TECHTRONIC INDUSTRIES CORDLESS GP 315 Power Dr. Anderson, SC 29621 Jim Vaspoli Phone: 864 332 5553 CALIBRATION Valid To: May 31, 2027 Certificate Number: 5918.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 3: I. Dimensional Parameter/Equipment Range CMC2, 5 (±) Comments Micrometers Up to 1 in (>1 to 6) in (>6 to 10) in (>10 to 12) in (9 + 1.5L) µin (41 + 1.5L) µin (70 + 1.4L) µin (140 + 1.8L) µin Gage blocks (Grade 00) Calipers Up to 8 in (>8 to 12) in (910 + 1.4L) µin (460 + 6.2L) µin Caliper checker 515-565 II. Dimensional Testing/Calibration Parameter/Equipment Range CMC2, 5, 8(±) Comments 1D Length4 – Measure Up to 1 in (>1 to 6) in (>6 to 10) in (>10 to 12) in (12 + 1.5L) µin (94 + 1.5L) µin (180 + 1.4L) µin (220 + 1.8L) µin Micrometer
to 12 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 2 of 16 III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage – Generate (0 to 330) mV 330 mV to 3.3 V (3.3 to 30) V (30 to 330) V (100 to 1020) V 16 µV/V + 1 µV 8.7 µV/V + 2 µV 9.4 µV/V + 20 µV 14 µV/V + 0.15 mV 14 µV/V + 1.5 mV Fluke 5522A DC Voltage – Measure (0 to 202) mV 202 mV to 2.02 V (2.02 to 20.2) V (20.2 to 202) V (202 to 1050) V (>1 to 20) kV 6.8 µV/V + 0.2 µV 3.5 µV/V + 0.3 µV 3.0 µV/V + 0.5 µV 4.6 µV/V + 30 µV 4.8 µV/V + 0.5 mV 82 µV/V Fluke 8588A Ohm Labs kV-30 DC Current – Measure (0 to 20.2) μA (20.2 to 202) μA 202 µA to 2.02 mA (2.02 to 20.2) mA (20.2 to 202) mA 202 mA to 2.02 A (2.02 to 20.2) A (20.2 to 30.2) A Up to 30 A (30 to 50) A (50 to 100) A (100 to 500) A 40 μA/A + 0.40 nA 12 μA/A + 0.40 nA 11 μA/A + 4.0 nA 12 μA/A + 40 nA 36 μA/A + 1.0 µA 0.10 mA/A + 100 µA 0.27 mA/A + 0.40 mA 0.51 mA/A + 4.4 mA 4.2 mA/A 9.5 µA/A 8.4 mA/A 14 mA/A Fluke 8588A Fluke 8588A w/ CS-50 shunt Fluke 8588A w/ CS-100 shunt Fluke 8588A w/ CS-500 shunt DC Current – Generate Up to 330 µA 330 µA to 3.3 mA (3.3 to 30) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (20.5 to 120) A (120 to 500) A 0.13 mA/A + 20 nA 78 µA/A + 50 nA 78 µA/A + 250 nA 78 µA/A + 2.5 µA 0.16 mA/A + 40 µA 0.30 mA/A + 40 µA 0.39 mA/A + 0.50 mA 0.78 mA/A + 0.75 mA 2.4 µA/A 0.34 µA/A Fluke 5522A Fluke 5522A/52120A Fluke 8588A Ohm Labs CS-500
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 3 of 16 Parameter/Equipment Range CMC2, 5, 7 (±) Comments DC Current – Generate Coils Up to 200 A Up to 1000 A Up to 2500 A 3.7 mA/A 2.5 mA/A 1.3 mA/A Fluke 5522A/52120A w/ 9100-200 52120A coil 3KA Parameter/Range Frequency CMC2, 5, 7 (±) Comments DC Power – Generate 33 mV to 1020 V (0.33 to 330) mA (0.33 to 3) A (3 to 20.5) A 11 µW to 337 W 11 mW to 3.1 kW 0.1 W to 21 kW 0.018 % 0.019 % 0.12 % Fluke 5522A Parameter/Equipment Range CMC2, 5, 7 (±) Comments Resistance – Generate Up to 11 Ω (>11 to 33) Ω (>33 to 110) Ω (>110 to 330) Ω >330 Ω to 1.1 kΩ (>1.1 to 3.3) kΩ (>3.3 to 11) kΩ (>11 to 33) kΩ (>33 to 110) kΩ (>110 to 330) kΩ >330 KΩ to 1.1 MΩ (>1.1 to 3.3) MΩ (>3.3 to 11) MΩ (>11 to 33) MΩ (>33 to 110) MΩ (>110 to 330) MΩ >330 MΩ to 1.1 GΩ 1.0 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 34 μΩ/Ω + 1.0 mΩ 24 μΩ/Ω + 1.5 mΩ 22 μΩ/Ω + 1.4 mΩ 22 μΩ/Ω + 2.0 mΩ 22 μΩ/Ω + 2.0 mΩ 22 μΩ/Ω + 20 mΩ 22 μΩ/Ω + 20 mΩ 22 μΩ/Ω + 0.20 Ω 22 μΩ/Ω + 0.20 Ω 25 μΩ/Ω + 2.0 Ω 26 μΩ/Ω + 2.0 Ω 48 μΩ/Ω + 30 Ω 0.10 mΩ/Ω + 50 Ω 0.20 mΩ/Ω + 2.5 kΩ 0.41 mΩ/Ω + 3 kΩ 2.4 mΩ/Ω + 0.10 MΩ 12 mΩ/Ω + 0.50 MΩ 0.20 mΩ/Ω 0.10 mΩ/Ω 0.10 mΩ/Ω 50 μΩ/Ω 20 μΩ/Ω 20 μΩ/Ω 16 μΩ/Ω 16 μΩ/Ω Fluke 5522A Ohm Labs 7804 fixed resistors
to 2500 A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 4 of 16 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Resistance – Measure Up to 2.02 Ω (>2.02 to 20.2) Ω (>20.2 to 202) Ω >202 Ω to 2.02 kΩ (>2.02 to 20.2) kΩ (>20.2 to 202) kΩ >202 kΩ to 2.02 MΩ (>2.02 to 20.2) MΩ (>20.2 to 202) MΩ >202 MΩ to 2.02 GΩ (>2.02 to 20.2) GΩ 20 μΩ/Ω + 4.0 μΩ 11 μΩ/Ω + 14 μΩ 8.2 μΩ/Ω + 50 μΩ 8.1 μΩ/Ω + 0.50 mΩ 8.2 μΩ/Ω + 5.0 mΩ 9.5 μΩ/Ω + 50 mΩ 10 μΩ/Ω + 1.0 Ω 16 μΩ/Ω + 10 Ω 0.12 mΩ/Ω + 10 kΩ 0.68 mΩ/Ω + 1.0 MΩ 0.29 Ω/Ω + 10 MΩ Fluke 8588A Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Generate (1 to 33) mV (33 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V (10 to 45) Hz >45 Hz to 10 kHz (>10 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 500) kHz (10 to 45) Hz >45 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 500) kHz (10 to 45) Hz >45 Hz to 10 kHz (>10 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 500) kHz (10 to 45) Hz >45 Hz to 10 kHz (>10 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz 45 Hz to 1 kHz (>1 to 10) kHz (>10 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz 45 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz 0.63 mV/V + 6.0 µV 0.17 mV/V + 6.0 µV 0.20 mV/V + 6.0 µV 0.79 mV/V + 6.0 µV 2.7 mV/V + 12 µV 6.2 mV/V + 50 µV 0.24 mV/V + 8.0 μV 0.13 mV/V + 8.0 μV 0.28 mV/V + 8.0 μV 0.63 mV/V + 32 μV 1.6 mV/V + 70 μV 0.24 mV/V + 50 μV 0.12 mV/V + 60 μV 0.15 mV/V + 60 μV 0.24 mV/V + 50 μV 0.55 mV/V + 0.13 mV 1.9 mV/V + 0.60 mV 0.24 mV/V + 0.65 mV 0.12 mV/V + 0.60 mV 0.19 mV/V + 0.60 mV 0.28 mV/V + 0.60 mV 0.70 mV/V + 1.6 mV 0.15 mV/V + 2.0 mV 0.16 mV/V + 6.0 mV 0.20 mV/V + 6.0 mV 0.24 mV/V + 6.0 mV 1.6 mV/V + 50 mV 0.24 mV/V + 10 mV 0.24 mV/V + 10 mV 0.24 mV/V + 10 mV Fluke 5522A
to 2.02 GΩ
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 5 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Measure (Up to 12.12) mV (12.12 to 121.2) mV 121.2 mV to 1.212 V (1.212 to 12.12) V (12.12 to 121.2) V 121.2 V to 1050 kV (>1 to 5) kV Up to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz >300 kHz to 1 MHz Up to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz >300 kHz to 1 MHz (>1 to 2) MHz (>2 to 4) MHz (>4 to 8) MHz (>8 to 10) MHz Up to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz >300 kHz to 1 MHz (>1 to 2) MHz (>2 to 4) MHz (>4 to 8) MHz (>8 to 10) MHz Up to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz >300 kHz to 1 MHz (>1 to 2) MHz (>2 to 4) MHz (>4 to 8) MHz (>8 to 10) MHz Up to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz >300 kHz to 1 MHz Up to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz 50/60 Hz 0.61 mV/V + 1.1 µV 0.55 mV/V + 1.1 µV 0.70 mV/V + 1.1 µV 3.2 mV/V + 1.1 µV 10 mV/V + 4 µV 21 mV/V + 4 µV 78 µV/V + 0.5 µV 0.12 mV/V + 0.5 µV 0.22 mV/V + 1.0 µV 0.53 mV/V + 5.0 µV 2.1 mV/V + 30 µV 10 mV/V + 100 µV 15 mV/V + 0.50 mV 40 mV/V + 1.0 mV 81 mV/V + 1.0 mV 0.15 V/V + 1.0 mV 67 µV/V + 5.0 µV 0.11 mV/V + 5.0 µV 0.21 mV/V + 10 µV 0.53 mV/V + 50 µV 2.1 mV/V + 0.30 mV 10 mV/V + 1.0 mV 15 mV/V + 5.0 mV 40 mV/V + 10 mV 81 mV/V + 10 mV 0.15 V/V + 10 mV 67 µV/V + 50 µV 0.11 mV/V + 20 µV 0.21 mV/V + 100 µV 0.53 mV/V + 0.5 mV 2.2 mV/V + 3.0 mV 10 mV/V + 10 mV 15 mV/V + 50 mV 40 mV/V + 0.1 V 80 mV/V + 0.1 V 0.15 V/V + 0.1 V 74 µV/V + 0.5 mV 93 µV/V + 0.5 mV 0.23 mV/V + 1.0 mV 0.54 mV/V + 5.0 mV 4.8 mV/V + 50 mV 27 mV/V + 0.5 V 91 µV/V + 25 mV 0.10 mV/V + 25 mV 0.34 mV/V + 25 mV 0.67 mV/V + 100 mV 0.70 mV/V Fluke 8588A Fluke 8588A w/ Ohm Labs kV-30
to 1050 kV
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 6 of 16 Parameter/Range Frequency CMC2, 5, 7 (±) Comments AC Power – Generate (45 to 65) Hz; PF=1 (33 to 330) mV (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A 330 mV to 1020 V (3.3 to 8.99) mA (9 to 32.99) mA (33 to 89.99) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A 110 µW to 3 mW (3 to 11) mW (1.1 to 30) mW (3 to 110) mW (11 to 300) mW (30 to 730) mW 73 mW to 1.5 W 150 mW to 6.8 W 1.1 mW to 9 W 3 mW to 33 W 11 mW to 90 W 30 mW to 330 W 110 mW to 900 W 300 mW to 2200 W 730 mW to 4500 W 1.5 W to 20.9 kW 0.08 % 0.016 % 0.075 % 0.016 % 0.075 % 0.057 % 0.11 % 0.13 % 0.013 % 0.015 % 0.013 % 0.016 % 0.018 % 0.017 % 0.020 % 0.024 % Fluke 5522A AC Current – Generate Coils (1 to 500) A (>500 to 3000) A (1 to 6000) A (10 to 400) Hz (50 to 400) Hz 3.5 mA/A 1.7 mA/A 3.3 mA/A 52120A/Coil 3KA 52120A/Coil 6KA
45 to 65 Hz
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 7 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Generate (29 to 329.99) µA 330 µA to 3.299 99 mA (3.3 to 32.9999) mA (33 to 329.999) mA 330 mA to 1.099 99 A (1.1 to 2.9999) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (>20 to 45) Hz >45 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (>10 to 30) kHz (10 to 20) Hz (>20 to 45) Hz >45 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (>10 to 30) kHz (10 to 20) Hz (>20 to 45) Hz >45 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (>10 to 30) kHz (10 to 20) Hz (>20 to 45) Hz >45 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (>10 to 30) kHz (10 to 45) Hz >45 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (>10 to 30) kHz (10 to 45) Hz >45 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (45 to 100) Hz >100 Hz to 1 kHz (>1 to 5) kHz (45 to 100) Hz >100 Hz to 1 kHz (>1 to 5) kHz 1.6 mA/A + 0.10 µA 1.2 mA/A + 0.10 µA 1.0 mA/A + 0.10 µA 2.4 mA/A + 0.15 µA 6.3 mA/A + 0.20 µA 13 mA/A + 0.40 µA 1.6 mA/A + 0.15 μA 0.97 mA/A + 0.15 µA 0.78 mA/A + 0.15 µA 1.6 mA/A + 0.20 µA 3.9 mA/A + 0.32 µA 7.8 mA/A + 0.60 µA 1.4 mA/A + 2.0 μA 0.70 mA/A + 2.0 µA 0.32 mA/A + 2.0 µA 0.62 mA/A + 2.0 µA 1.6 mA/A + 3.0 µA 3.2 mA/A + 4.0 µA 1.4 mA/A + 20 μA 0.70 mA/A + 20 µA 0.32 mA/A + 20 µA 0.78 mA/A + 50 µA 1.6 mA/A + 0.10 mA 3.2 mA/A + 0.20 mA 1.4 mA/A + 0.10 mA 0.40 mA/A + 0.10 mA 4.7 mA/A + 1.0 mA 20 mA/A + 5.0 mA 3.2 mA/A + 0.20 mA 1.4 mA/A + 0.10 mA 0.47 mA/A + 0.10 mA 4.7 mA/A + 1.0 mA 20 mA/A + 5.0 mA 0.47 mA/A + 2.0 mA 0.78 mA/A + 2.0 mA 24 mA/A + 2.0 mA 0.94 mA/A + 5.0 mA 1.2 mA/A + 5.0 mA 24 mA/A + 5.0 mA Fluke 5522A
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 8 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Generate (cont) (20.5 to 100) A (>100 to 120) A (45 Hz to 150) Hz >150 Hz to 4 kHz (>4 to 10) kHz (45 to 150) Hz >150 Hz to 10 kHz 1.2 mA/A 22 mA/A 54 mA/A 0.56 mA/A 38 mA/A Fluke 5522A w/ 52120A w/ 8588A w/ A40B Fluke 5522A w/ 52120A AC Current – Measure Up to 20.2 μA (>20.2 to 202) μA >202 μA to 2.02 mA (>2.02 to 20.2) mA (>20.2to 202) mA >202 mA to 2.02 A (>2.02 to 20.2) A (>20.2 to 30.2) A (>20 to 100) A 1 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 1 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 1 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 1 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 1 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 1 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 10 Hz to 2 kHz (>2 to 10) kHz 10 Hz to 2 kHz (>2 to 10) kHz (10 to 150) Hz >150 Hz to 10 kHz 2.1 mA/A + 2.5 nA 2.1 mA/A + 2.5 nA 2.1 mA/A + 2.5 nA 0.30 mA/A + 5.0 nA 0.53 mA/A + 5.0 nA 0.81 mA/A + 5.0 nA 0.27 mA/A + 50 nA 0.52 mA/A + 50 nA 0.78 mA/A + 50 nA 0.27 mA/A + 500 nA 0.52 mA/A + 500 nA 0.79 mA/A + 500 nA 0.27 mA/A + 5 μA 0.51 mA/A + 5 μA 0.71 mA/A + 5 μA 0.28 mA/A + 0.10 mA 0.56 mA/A + 0.10 mA 0.86 mA/A + 0.10 mA 0.86 mA/A + 0.50 mA 1.4 mA/A + 0.50 mA 0.13 mA/A 0.16 mA/A 0.14 mA/A 0.29 mA/A Fluke 8588A Fluke 8588A w/ A40B
20.5 to 100 A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 9 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Capacitance – Generate (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 0.0043 % + 10 pF 0.0040 % + 10 pF 0.0040 % + 10 pF 0.0021 % + 10 pF 0.0021 % + 10 pF 0.0021 % + 10 pF 0.0021 % + 30 pF 0.0021 % + 1.0 nF 0.0021 % + 3.0 nF 0.0021 % + 10 nF 0.0032 % + 30 nF 0.0037 % + 100 nF 0.0035 % + 300 nF 0.0035 % + 1.0 µF 0.0035 % + 3.0 µF 0.0035 % + 10 µF 0.0058 % + 30 µF 0.0086 % + 0.10 mF Fluke 5522A Parameter/Equipment Range CMC2, 7 (±) Comments Total Harmonic Distortion – Measure 10 Hz to 6 kHz (0.5 to 80) % THD 0.020 % THD Chroma 66205
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 10 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Oscilloscopes – DC Voltage 50 Ω Load 1 MΩ Load AC Voltage (Square Wave) 50 Ω Load 1 MΩ Load Level Sine Amplitude @ 50 kHz Level Sine Flatness Time Marker 1 mV to ± 6.6 V 1 mV to ± 130 V ±1 mVpp to ±6.6 Vpp 10 Hz to 10 kHz ±1 mVpp to ±130 Vpp 10 Hz to 10 kHz 5 mV to 5.5 V 5 mV to 3.5 V 5 mV to 5.5 V 50 kHz to 1 MHz (>1 to 100) MHz (>100 to 1100) MHz 1 ns to 20 ms 50 ms to 5 s 2.1 mV/V + 40 µV 0.41 mV/V + 40 µV 2.0 mV/V + 40 µV 0.79 mV/V + 40 µV 16 mV/V + 0.30 mV 16 mV/V + 0.30 mV 2.8 % rdg + 0.10 mV 0.6 % rdg + 0.10 mV 0.11 % rdg + 0.10 mV 6 µs/s 60 µs/s Fluke 5522A/SC1100 Relative to 50 kHz reference frequency
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 11 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Electrical Calibration of Thermocouples – Generate Type C Type E Type J Type K Type N Type R Type S Type T (0 to 150) °C (>150 to 650) °C (>650 to 1000) °C (>1000 to 1800) °C (>1800 to 2316) °C (-250 to -100) °C (>-100 to -25) °C (>-25 to 350) °C (>350 to 650) °C (>650 to 1000) °C (-210 to -100) °C (>-100 to -30) °C (>-30 to 150) °C (>150 to 760) °C (>760 to 1200) °C (-200 to -100) °C (>-100 to -25) °C (>-25 to 120) °C (>120 to 1000) °C (>1000 to 1372) °C (-200 to -100) °C (>-100 to -25) °C (>-25 to 120) °C (>120 to 410) °C (>410 to 1300) °C (0 to 250) °C (>250 to 400) °C (>400 to 1000) °C (>1000 to 1767) °C (0 to 250) °C (>250 to 1000) °C (>1000 to 1400) °C (>1400 to 1767) °C (-250 to -150) °C (>-150 to 0) °C (>0 to 120) °C (>120 to 400) °C 0.23 °C 0.20 °C 0.24 °C 0.39 °C 0.65 °C 0.39 °C 0.12 °C 0.11 °C 0.12 °C 0.16 °C 0.21 °C 0.13 °C 0.11 °C 0.13 °C 0.18 °C 0.26 °C 0.14 °C 0.13 °C 0.20 °C 0.31 °C 0.31 °C 0.17 °C 0.15 °C 0.14 °C 0.21 °C 0.44 °C 0.27 °C 0.26 °C 0.31 °C 0.37 °C 0.28 °C 0.29 °C 0.36 °C 0.49 °C 0.19 °C 0.13 °C 0.11 °C Fluke 5522A
to 2316 °C
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 12 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Electrical Calibration of Thermocouples – Measure Type C Type E Type J Type K Type N Type R Type S Type T (0 to 150) °C (>150 to 650) °C (>650 to 1000) °C (>1000 to 1800) °C (>1800 to 2316) °C (-250 to -100) °C (>-100 to -25) °C (>-25 to 350) °C (>350 to 650) °C (>650 to 1000) °C (-210 to -100) °C (>-100 to -30) °C (>-30 to 150) °C (>150 to 760) °C (>760 to 1200) °C (-200 to -100) °C (>-100 to -25) °C (>-25 to 120) °C (>120 to 1000) °C (>1000 to 1372) °C (-200 to -100) °C (>-100 to -25) °C (>-25 to 120) °C (>120 to 410) °C (>410 to 1300) °C (0 to 250) °C (>250 to 400) °C (>400 to 1000) °C (>1000 to 1767) °C (0 to 250) °C (>250 to 1000) °C (>1000 to 1400) °C (>1400 to 1767) °C (-250 to -150) °C (>-150 to 0) °C (>0 to 120) °C (>120 to 400) °C 42 m °C 42 m °C 44 m °C 46 m °C 48 m °C 68 m °C 68 m °C 11 m °C 11 m °C 11 m °C 14 m °C 14 m °C 14 m °C 15 m °C 13 m °C 0.14 °C 0.14 °C 20 m °C 16 m °C 16 m °C 0.24 °C 0.24 °C 18 m °C 15 m °C 35 m °C 46 m °C 45 m °C 43 m °C 41 m °C 44 m °C 42 m °C 41 m °C 42 m °C 90 m °C 90 m °C 9.7 m °C 9.7 m °C Fluke 8588A
to 2316 °C
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 13 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Electrical Calibration of RTDs – Measure & Generate Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω PtNi, 120 Ω (Ni 120) Cu 427, 10 Ω (-200 to 0) °C (>0 to 100) °C (>100 to 300) °C (>300 to 400) °C (>400 to 630) °C (>630 to 800) °C (-200 to 0) °C (>0 to 100) °C (>100 to 300) °C (300 to 400) °C (>400 to 630) °C (-200 to -190) °C (>-190 to -80) °C (>-80 to 0) °C (>0 to 100) °C (>100 to 260) °C (>260 to 300) °C (>300 to 400) °C (>400 to 600) °C (>600 to 630) °C (-200 to 100) °C (>100 to 260) °C (>260 to 300) °C (>300 to 400) °C (>400 to 600) °C (>600 to 630) °C (-200 to -80) °C (>-80 to 100) °C (>100 to 260) °C (>260 to 400) °C (>400 to 600) °C (>600 to 630) °C (-200 to 0) °C (>0 to 100) °C (>100 to 260) °C (>260 to 300) °C (>300 to 600) °C (>600 to 630) °C (-80 to 100) °C (>100 to 260) °C (-100 to 260) °C 0.042 °C 0.055 °C 0.071 °C 0.079 °C 0.095 °C 0.18 °C 0.045 °C 0.059 °C 0.072 °C 0.079 °C 0.095 °C 0.19 °C 0.032 °C 0.041 °C 0.049 °C 0.056 °C 0.065 °C 0.072 °C 0.079 °C 0.18 °C 0.033 °C 0.043 °C 0.095 °C 0.10 °C 0.11 °C 0.13 °C 0.032 °C 0.041 °C 0.050 °C 0.063 °C 0.071 °C 0.086 °C 0.027 °C 0.032 °C 0.040 °C 0.048 °C 0.055 °C 0.18 °C 0.063 °C 0.11 °C 0.12 °C Fluke 5522A 4 wire compensation
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 14 of 16 IV. Mechanical Parameter/Equipment Range CMC2, 5, 8 (±) Comments Pressure – Measuring Equipment & Measure Hydraulic Pneumatic Vacuum (10 to 500) psig (500 to 10 000) psig Up to 500 psig Up to 15 inHg (>15 to 27) inHg 0.047 % 0.031 % 0.13 % 0.10 % 0.68 % Fluke P3124-3 Dwyer DCG II-107 Additel ADT681 Scales & Balances (0.05 to 0.2) oz (>0.2 to 8) oz (1 to 2) lb (>2 to 50) lb (>50 to 500) lb (1 to 2) g (>2 to 20) g >20 g to 5 kg 0.081 % + 0.6R 0.024 % + 0.6R 0.020 % + 0.6R 0.010 % + 0.6R 0.008 % + 0.6R 0.20 % + 0.6R 0.042 % + 0.6R 0.024 % + 0.6R Class F weights Torque – Measure6 (4 to 50) lbf·in (30 to 400) lbf·in (80 to 1000) lbf·in (20 to 250) lbf·ft 0.12 % 0.12 % 0.064 % 0.052 % CDI 5000ST w/ 2000-400-02 Torque – Measuring Equipment (5 to 100) lbf·in 10 lbf·in to 250 lbf·ft 0.017 % 0.036 % Lever arms & traceable hanging weights Force – Measure & Measuring Equipment Compression & Tension (10 to <500) lbf (500 to 2000) lbf 0.21 lbf 0.66 lbf Comparison w/ standard load cell RPM – Measuring Equipment Optical (1 to 1000) RPM (1000 to 99 000) RPM 0.035 RPM 1.2 RPM Keysight 33622A w/ GPS reference & LED fixture RPM – Measure Non-Contact (6 to 10 000) RPM (10 000 to 99 000) RPM 0.89 RPM 2.4 RPM Shimpo 207LT
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 15 of 16 V. Thermodynamics Parameter/Equipment Range CMC2, 5, 8 (±) Comments Temperature – Measure (-190 to 100) °C (>100 to 500) °C (-70 to 180) °C 0.04 °C 0.11 °C 0.09 °C + 0.60R Fluke 1524 w/ 5609 Vaisala HMP77 Humidity – Generate & Measure Up to 25 °C (>25 to 40) °C Up to 30 % RH (>30 to <85) % RH 85% RH Up to 35 % RH 1.6 % RH 1.4 % RH 1.9 % RH 1.6 % RH Vaisala HMP77 VI. Time & Frequency Parameter/Equipment Range CMC2, 5, 8 (±) Comments Frequency – Generate 10 MHz 10 Hz to 1 GHz 10 mHz to 120 MHz 2.5 x 10-12 Hz 2.5 x 10 -12 Hz + 5 µHz 2.5 x 10-12 Hz GPS reference 5522A w/ GPS reference 33622A w/ GPS reference Frequency – Measure Up to 2 kHz (>2 to 200) kHz >200 kHz to 20 MHz (>20 to 100) MHz (>100 to 350) MHz 0.16 nHz 5.2 nHz 1.1 µHz 3.8 µHz 0.24 mHz Frequency counters w/ external reference Stopwatches & Timers Up to 24 hr 0.02 sec/day + 0.60R Timometer _____________________________ 1 This laboratory is not normally available for commercial calibration service.
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5918.01) 4/17/2025 Page 16 of 16 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, R is the resolution of the unit under test, and % is defined as percent of reading unless otherwise noted. 6 The contributions from the “best existing device” are not included in the CMC claim. 7 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
17ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

315 Power Drive, Anderson, SC, 29621, US

34.52583, -82.65296

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.