Techtronic Industries Cordless GP
315 Power Drive, 29621, Anderson, SC, United States
- Scope lines
- 17
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
A2LA certificate 5918.01 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 1 of 16
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
TECHTRONIC INDUSTRIES CORDLESS GP
315 Power Dr.
Anderson, SC 29621
Jim Vaspoli Phone: 864 332 5553
CALIBRATION
Valid To: May 31, 2027 Certificate Number: 5918.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 3:
I. Dimensional
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Micrometers
Up to 1 in
(>1 to 6) in
(>6 to 10) in
(>10 to 12) in
(9 + 1.5L) µin
(41 + 1.5L) µin
(70 + 1.4L) µin
(140 + 1.8L) µin
Gage blocks (Grade
00)
Calipers
Up to 8 in
(>8 to 12) in
(910 + 1.4L) µin
(460 + 6.2L) µin
Caliper checker
515-565
II. Dimensional Testing/Calibration
Parameter/Equipment
Range
CMC2, 5, 8(±)
Comments
1D Length4 – Measure
Up to 1 in
(>1 to 6) in
(>6 to 10) in
(>10 to 12) in
(12 + 1.5L) µin
(94 + 1.5L) µin
(180 + 1.4L) µin
(220 + 1.8L) µin
Micrometer | to 12 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 2 of 16
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Voltage – Generate
(0 to 330) mV
330 mV to 3.3 V
(3.3 to 30) V
(30 to 330) V
(100 to 1020) V
16 µV/V + 1 µV
8.7 µV/V + 2 µV
9.4 µV/V + 20 µV
14 µV/V + 0.15 mV
14 µV/V + 1.5 mV
Fluke 5522A
DC Voltage – Measure
(0 to 202) mV
202 mV to 2.02 V
(2.02 to 20.2) V
(20.2 to 202) V
(202 to 1050) V
(>1 to 20) kV
6.8 µV/V + 0.2 µV
3.5 µV/V + 0.3 µV
3.0 µV/V + 0.5 µV
4.6 µV/V + 30 µV
4.8 µV/V + 0.5 mV
82 µV/V
Fluke 8588A
Ohm Labs kV-30
DC Current – Measure
(0 to 20.2) μA
(20.2 to 202) μA
202 µA to 2.02 mA
(2.02 to 20.2) mA
(20.2 to 202) mA
202 mA to 2.02 A
(2.02 to 20.2) A
(20.2 to 30.2) A
Up to 30 A
(30 to 50) A
(50 to 100) A
(100 to 500) A
40 μA/A + 0.40 nA
12 μA/A + 0.40 nA
11 μA/A + 4.0 nA
12 μA/A + 40 nA
36 μA/A + 1.0 µA
0.10 mA/A + 100 µA
0.27 mA/A + 0.40 mA
0.51 mA/A + 4.4 mA
4.2 mA/A
9.5 µA/A
8.4 mA/A
14 mA/A
Fluke 8588A
Fluke 8588A w/
CS-50 shunt
Fluke 8588A w/
CS-100 shunt
Fluke 8588A w/
CS-500 shunt
DC Current – Generate
Up to 330 µA
330 µA to 3.3 mA
(3.3 to 30) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(20.5 to 120) A
(120 to 500) A
0.13 mA/A + 20 nA
78 µA/A + 50 nA
78 µA/A + 250 nA
78 µA/A + 2.5 µA
0.16 mA/A + 40 µA
0.30 mA/A + 40 µA
0.39 mA/A + 0.50 mA
0.78 mA/A + 0.75 mA
2.4 µA/A
0.34 µA/A
Fluke 5522A
Fluke
5522A/52120A
Fluke 8588A
Ohm Labs CS-500 | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 3 of 16
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
DC Current – Generate
Coils
Up to 200 A
Up to 1000 A
Up to 2500 A
3.7 mA/A
2.5 mA/A
1.3 mA/A
Fluke 5522A/52120A
w/ 9100-200
52120A coil 3KA
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
DC Power – Generate
33 mV to 1020 V
(0.33 to 330) mA
(0.33 to 3) A
(3 to 20.5) A
11 µW to 337 W
11 mW to 3.1 kW
0.1 W to 21 kW
0.018 %
0.019 %
0.12 %
Fluke 5522A
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Resistance – Generate
Up to 11 Ω
(>11 to 33) Ω
(>33 to 110) Ω
(>110 to 330) Ω
>330 Ω to 1.1 kΩ
(>1.1 to 3.3) kΩ
(>3.3 to 11) kΩ
(>11 to 33) kΩ
(>33 to 110) kΩ
(>110 to 330) kΩ
>330 KΩ to 1.1 MΩ
(>1.1 to 3.3) MΩ
(>3.3 to 11) MΩ
(>11 to 33) MΩ
(>33 to 110) MΩ
(>110 to 330) MΩ
>330 MΩ to 1.1 GΩ
1.0 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
34 μΩ/Ω + 1.0 mΩ
24 μΩ/Ω + 1.5 mΩ
22 μΩ/Ω + 1.4 mΩ
22 μΩ/Ω + 2.0 mΩ
22 μΩ/Ω + 2.0 mΩ
22 μΩ/Ω + 20 mΩ
22 μΩ/Ω + 20 mΩ
22 μΩ/Ω + 0.20 Ω
22 μΩ/Ω + 0.20 Ω
25 μΩ/Ω + 2.0 Ω
26 μΩ/Ω + 2.0 Ω
48 μΩ/Ω + 30 Ω
0.10 mΩ/Ω + 50 Ω
0.20 mΩ/Ω + 2.5 kΩ
0.41 mΩ/Ω + 3 kΩ
2.4 mΩ/Ω + 0.10 MΩ
12 mΩ/Ω + 0.50 MΩ
0.20 mΩ/Ω
0.10 mΩ/Ω
0.10 mΩ/Ω
50 μΩ/Ω
20 μΩ/Ω
20 μΩ/Ω
16 μΩ/Ω
16 μΩ/Ω
Fluke 5522A
Ohm Labs 7804 fixed
resistors | to 2500 A |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 4 of 16
Parameter/Equipment
Range CMC2, 5, 7 (±)
Comments
Resistance – Measure
Up to 2.02 Ω
(>2.02 to 20.2) Ω
(>20.2 to 202) Ω
>202 Ω to 2.02 kΩ
(>2.02 to 20.2) kΩ
(>20.2 to 202) kΩ
>202 kΩ to 2.02 MΩ
(>2.02 to 20.2) MΩ
(>20.2 to 202) MΩ
>202 MΩ to 2.02 GΩ
(>2.02 to 20.2) GΩ
20 μΩ/Ω + 4.0 μΩ
11 μΩ/Ω + 14 μΩ
8.2 μΩ/Ω + 50 μΩ
8.1 μΩ/Ω + 0.50 mΩ
8.2 μΩ/Ω + 5.0 mΩ
9.5 μΩ/Ω + 50 mΩ
10 μΩ/Ω + 1.0 Ω
16 μΩ/Ω + 10 Ω
0.12 mΩ/Ω + 10 kΩ
0.68 mΩ/Ω + 1.0 MΩ
0.29 Ω/Ω + 10 MΩ
Fluke 8588A
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Generate
(1 to 33) mV
(33 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
(10 to 45) Hz
>45 Hz to 10 kHz
(>10 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 500) kHz
(10 to 45) Hz
>45 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 500) kHz
(10 to 45) Hz
>45 Hz to 10 kHz
(>10 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 500) kHz
(10 to 45) Hz
>45 Hz to 10 kHz
(>10 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
45 Hz to 1 kHz
(>1 to 10) kHz
(>10 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
45 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
0.63 mV/V + 6.0 µV
0.17 mV/V + 6.0 µV
0.20 mV/V + 6.0 µV
0.79 mV/V + 6.0 µV
2.7 mV/V + 12 µV
6.2 mV/V + 50 µV
0.24 mV/V + 8.0 μV
0.13 mV/V + 8.0 μV
0.28 mV/V + 8.0 μV
0.63 mV/V + 32 μV
1.6 mV/V + 70 μV
0.24 mV/V + 50 μV
0.12 mV/V + 60 μV
0.15 mV/V + 60 μV
0.24 mV/V + 50 μV
0.55 mV/V + 0.13 mV
1.9 mV/V + 0.60 mV
0.24 mV/V + 0.65 mV
0.12 mV/V + 0.60 mV
0.19 mV/V + 0.60 mV
0.28 mV/V + 0.60 mV
0.70 mV/V + 1.6 mV
0.15 mV/V + 2.0 mV
0.16 mV/V + 6.0 mV
0.20 mV/V + 6.0 mV
0.24 mV/V + 6.0 mV
1.6 mV/V + 50 mV
0.24 mV/V + 10 mV
0.24 mV/V + 10 mV
0.24 mV/V + 10 mV
Fluke 5522A | to 2.02 GΩ |
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 5 of 16
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Measure
(Up to 12.12) mV
(12.12 to 121.2) mV
121.2 mV to 1.212 V
(1.212 to 12.12) V
(12.12 to 121.2) V
121.2 V to 1050 kV
(>1 to 5) kV
Up to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
Up to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 2) MHz
(>2 to 4) MHz
(>4 to 8) MHz
(>8 to 10) MHz
Up to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 2) MHz
(>2 to 4) MHz
(>4 to 8) MHz
(>8 to 10) MHz
Up to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 2) MHz
(>2 to 4) MHz
(>4 to 8) MHz
(>8 to 10) MHz
Up to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
Up to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
50/60 Hz
0.61 mV/V + 1.1 µV
0.55 mV/V + 1.1 µV
0.70 mV/V + 1.1 µV
3.2 mV/V + 1.1 µV
10 mV/V + 4 µV
21 mV/V + 4 µV
78 µV/V + 0.5 µV
0.12 mV/V + 0.5 µV
0.22 mV/V + 1.0 µV
0.53 mV/V + 5.0 µV
2.1 mV/V + 30 µV
10 mV/V + 100 µV
15 mV/V + 0.50 mV
40 mV/V + 1.0 mV
81 mV/V + 1.0 mV
0.15 V/V + 1.0 mV
67 µV/V + 5.0 µV
0.11 mV/V + 5.0 µV
0.21 mV/V + 10 µV
0.53 mV/V + 50 µV
2.1 mV/V + 0.30 mV
10 mV/V + 1.0 mV
15 mV/V + 5.0 mV
40 mV/V + 10 mV
81 mV/V + 10 mV
0.15 V/V + 10 mV
67 µV/V + 50 µV
0.11 mV/V + 20 µV
0.21 mV/V + 100 µV
0.53 mV/V + 0.5 mV
2.2 mV/V + 3.0 mV
10 mV/V + 10 mV
15 mV/V + 50 mV
40 mV/V + 0.1 V
80 mV/V + 0.1 V
0.15 V/V + 0.1 V
74 µV/V + 0.5 mV
93 µV/V + 0.5 mV
0.23 mV/V + 1.0 mV
0.54 mV/V + 5.0 mV
4.8 mV/V + 50 mV
27 mV/V + 0.5 V
91 µV/V + 25 mV
0.10 mV/V + 25 mV
0.34 mV/V + 25 mV
0.67 mV/V + 100 mV
0.70 mV/V
Fluke 8588A
Fluke 8588A w/
Ohm Labs kV-30 | to 1050 kV |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 6 of 16
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
AC Power – Generate
(45 to 65) Hz; PF=1
(33 to 330) mV
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(0.33 to 0.8999) A
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
330 mV to 1020 V
(3.3 to 8.99) mA
(9 to 32.99) mA
(33 to 89.99) mA
(90 to 329.99) mA
(0.33 to 0.8999) A
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
110 µW to 3 mW
(3 to 11) mW
(1.1 to 30) mW
(3 to 110) mW
(11 to 300) mW
(30 to 730) mW
73 mW to 1.5 W
150 mW to 6.8 W
1.1 mW to 9 W
3 mW to 33 W
11 mW to 90 W
30 mW to 330 W
110 mW to 900 W
300 mW to 2200 W
730 mW to 4500 W
1.5 W to 20.9 kW
0.08 %
0.016 %
0.075 %
0.016 %
0.075 %
0.057 %
0.11 %
0.13 %
0.013 %
0.015 %
0.013 %
0.016 %
0.018 %
0.017 %
0.020 %
0.024 %
Fluke 5522A
AC Current – Generate Coils
(1 to 500) A
(>500 to 3000) A
(1 to 6000) A
(10 to 400) Hz
(50 to 400) Hz
3.5 mA/A
1.7 mA/A
3.3 mA/A
52120A/Coil 3KA
52120A/Coil 6KA | 45 to 65 Hz |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 7 of 16
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Generate
(29 to 329.99) µA
330 µA to 3.299 99 mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
330 mA to 1.099 99 A
(1.1 to 2.9999) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 20) Hz
(>20 to 45) Hz
>45 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(>10 to 30) kHz
(10 to 20) Hz
(>20 to 45) Hz
>45 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(>10 to 30) kHz
(10 to 20) Hz
(>20 to 45) Hz
>45 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(>10 to 30) kHz
(10 to 20) Hz
(>20 to 45) Hz
>45 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(>10 to 30) kHz
(10 to 45) Hz
>45 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(>10 to 30) kHz
(10 to 45) Hz
>45 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(45 to 100) Hz
>100 Hz to 1 kHz
(>1 to 5) kHz
(45 to 100) Hz
>100 Hz to 1 kHz
(>1 to 5) kHz
1.6 mA/A + 0.10 µA
1.2 mA/A + 0.10 µA
1.0 mA/A + 0.10 µA
2.4 mA/A + 0.15 µA
6.3 mA/A + 0.20 µA
13 mA/A + 0.40 µA
1.6 mA/A + 0.15 μA
0.97 mA/A + 0.15 µA
0.78 mA/A + 0.15 µA
1.6 mA/A + 0.20 µA
3.9 mA/A + 0.32 µA
7.8 mA/A + 0.60 µA
1.4 mA/A + 2.0 μA
0.70 mA/A + 2.0 µA
0.32 mA/A + 2.0 µA
0.62 mA/A + 2.0 µA
1.6 mA/A + 3.0 µA
3.2 mA/A + 4.0 µA
1.4 mA/A + 20 μA
0.70 mA/A + 20 µA
0.32 mA/A + 20 µA
0.78 mA/A + 50 µA
1.6 mA/A + 0.10 mA
3.2 mA/A + 0.20 mA
1.4 mA/A + 0.10 mA
0.40 mA/A + 0.10 mA
4.7 mA/A + 1.0 mA
20 mA/A + 5.0 mA
3.2 mA/A + 0.20 mA
1.4 mA/A + 0.10 mA
0.47 mA/A + 0.10 mA
4.7 mA/A + 1.0 mA
20 mA/A + 5.0 mA
0.47 mA/A + 2.0 mA
0.78 mA/A + 2.0 mA
24 mA/A + 2.0 mA
0.94 mA/A + 5.0 mA
1.2 mA/A + 5.0 mA
24 mA/A + 5.0 mA
Fluke 5522A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 8 of 16
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Generate
(cont)
(20.5 to 100) A
(>100 to 120) A
(45 Hz to 150) Hz
>150 Hz to 4 kHz
(>4 to 10) kHz
(45 to 150) Hz
>150 Hz to 10 kHz
1.2 mA/A
22 mA/A
54 mA/A
0.56 mA/A
38 mA/A
Fluke 5522A
w/ 52120A
w/ 8588A
w/ A40B
Fluke 5522A
w/ 52120A
AC Current – Measure
Up to 20.2 μA
(>20.2 to 202) μA
>202 μA to 2.02 mA
(>2.02 to 20.2) mA
(>20.2to 202) mA
>202 mA to 2.02 A
(>2.02 to 20.2) A
(>20.2 to 30.2) A
(>20 to 100) A
1 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
1 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
1 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
1 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
1 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
1 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
(10 to 150) Hz
>150 Hz to 10 kHz
2.1 mA/A + 2.5 nA
2.1 mA/A + 2.5 nA
2.1 mA/A + 2.5 nA
0.30 mA/A + 5.0 nA
0.53 mA/A + 5.0 nA
0.81 mA/A + 5.0 nA
0.27 mA/A + 50 nA
0.52 mA/A + 50 nA
0.78 mA/A + 50 nA
0.27 mA/A + 500 nA
0.52 mA/A + 500 nA
0.79 mA/A + 500 nA
0.27 mA/A + 5 μA
0.51 mA/A + 5 μA
0.71 mA/A + 5 μA
0.28 mA/A + 0.10 mA
0.56 mA/A + 0.10 mA
0.86 mA/A + 0.10 mA
0.86 mA/A + 0.50 mA
1.4 mA/A + 0.50 mA
0.13 mA/A
0.16 mA/A
0.14 mA/A
0.29 mA/A
Fluke 8588A
Fluke 8588A
w/ A40B | 20.5 to 100 A |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 9 of 16
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Capacitance – Generate
(220 to 399.9) pF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
0.0043 % + 10 pF
0.0040 % + 10 pF
0.0040 % + 10 pF
0.0021 % + 10 pF
0.0021 % + 10 pF
0.0021 % + 10 pF
0.0021 % + 30 pF
0.0021 % + 1.0 nF
0.0021 % + 3.0 nF
0.0021 % + 10 nF
0.0032 % + 30 nF
0.0037 % + 100 nF
0.0035 % + 300 nF
0.0035 % + 1.0 µF
0.0035 % + 3.0 µF
0.0035 % + 10 µF
0.0058 % + 30 µF
0.0086 % + 0.10 mF
Fluke 5522A
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Total Harmonic Distortion –
Measure
10 Hz to 6 kHz
(0.5 to 80) % THD
0.020 % THD
Chroma 66205 | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 10 of 16
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Oscilloscopes –
DC Voltage
50 Ω Load
1 MΩ Load
AC Voltage (Square Wave)
50 Ω Load
1 MΩ Load
Level Sine Amplitude
@ 50 kHz
Level Sine Flatness
Time Marker
1 mV to ± 6.6 V
1 mV to ± 130 V
±1 mVpp to ±6.6 Vpp
10 Hz to 10 kHz
±1 mVpp to ±130 Vpp
10 Hz to 10 kHz
5 mV to 5.5 V
5 mV to 3.5 V
5 mV to 5.5 V
50 kHz to 1 MHz
(>1 to 100) MHz
(>100 to 1100) MHz
1 ns to 20 ms
50 ms to 5 s
2.1 mV/V + 40 µV
0.41 mV/V + 40 µV
2.0 mV/V + 40 µV
0.79 mV/V + 40 µV
16 mV/V + 0.30 mV
16 mV/V + 0.30 mV
2.8 % rdg + 0.10 mV
0.6 % rdg + 0.10 mV
0.11 % rdg + 0.10 mV
6 µs/s
60 µs/s
Fluke
5522A/SC1100
Relative to 50
kHz reference
frequency | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 11 of 16
Parameter/Equipment
Range
CMC2, 7 (±) Comments
Electrical Calibration of
Thermocouples – Generate
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(0 to 150) °C
(>150 to 650) °C
(>650 to 1000) °C
(>1000 to 1800) °C
(>1800 to 2316) °C
(-250 to -100) °C
(>-100 to -25) °C
(>-25 to 350) °C
(>350 to 650) °C
(>650 to 1000) °C
(-210 to -100) °C
(>-100 to -30) °C
(>-30 to 150) °C
(>150 to 760) °C
(>760 to 1200) °C
(-200 to -100) °C
(>-100 to -25) °C
(>-25 to 120) °C
(>120 to 1000) °C
(>1000 to 1372) °C
(-200 to -100) °C
(>-100 to -25) °C
(>-25 to 120) °C
(>120 to 410) °C
(>410 to 1300) °C
(0 to 250) °C
(>250 to 400) °C
(>400 to 1000) °C
(>1000 to 1767) °C
(0 to 250) °C
(>250 to 1000) °C
(>1000 to 1400) °C
(>1400 to 1767) °C
(-250 to -150) °C
(>-150 to 0) °C
(>0 to 120) °C
(>120 to 400) °C
0.23 °C
0.20 °C
0.24 °C
0.39 °C
0.65 °C
0.39 °C
0.12 °C
0.11 °C
0.12 °C
0.16 °C
0.21 °C
0.13 °C
0.11 °C
0.13 °C
0.18 °C
0.26 °C
0.14 °C
0.13 °C
0.20 °C
0.31 °C
0.31 °C
0.17 °C
0.15 °C
0.14 °C
0.21 °C
0.44 °C
0.27 °C
0.26 °C
0.31 °C
0.37 °C
0.28 °C
0.29 °C
0.36 °C
0.49 °C
0.19 °C
0.13 °C
0.11 °C
Fluke 5522A | to 2316 °C |
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 12 of 16
Parameter/Equipment
Range CMC2, 7 (±) Comments
Electrical Calibration of
Thermocouples – Measure
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(0 to 150) °C
(>150 to 650) °C
(>650 to 1000) °C
(>1000 to 1800) °C
(>1800 to 2316) °C
(-250 to -100) °C
(>-100 to -25) °C
(>-25 to 350) °C
(>350 to 650) °C
(>650 to 1000) °C
(-210 to -100) °C
(>-100 to -30) °C
(>-30 to 150) °C
(>150 to 760) °C
(>760 to 1200) °C
(-200 to -100) °C
(>-100 to -25) °C
(>-25 to 120) °C
(>120 to 1000) °C
(>1000 to 1372) °C
(-200 to -100) °C
(>-100 to -25) °C
(>-25 to 120) °C
(>120 to 410) °C
(>410 to 1300) °C
(0 to 250) °C
(>250 to 400) °C
(>400 to 1000) °C
(>1000 to 1767) °C
(0 to 250) °C
(>250 to 1000) °C
(>1000 to 1400) °C
(>1400 to 1767) °C
(-250 to -150) °C
(>-150 to 0) °C
(>0 to 120) °C
(>120 to 400) °C
42 m °C
42 m °C
44 m °C
46 m °C
48 m °C
68 m °C
68 m °C
11 m °C
11 m °C
11 m °C
14 m °C
14 m °C
14 m °C
15 m °C
13 m °C
0.14 °C
0.14 °C
20 m °C
16 m °C
16 m °C
0.24 °C
0.24 °C
18 m °C
15 m °C
35 m °C
46 m °C
45 m °C
43 m °C
41 m °C
44 m °C
42 m °C
41 m °C
42 m °C
90 m °C
90 m °C
9.7 m °C
9.7 m °C
Fluke 8588A | to 2316 °C |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 13 of 16
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Electrical Calibration of RTDs
– Measure & Generate
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
PtNi, 120 Ω (Ni 120)
Cu 427, 10 Ω
(-200 to 0) °C
(>0 to 100) °C
(>100 to 300) °C
(>300 to 400) °C
(>400 to 630) °C
(>630 to 800) °C
(-200 to 0) °C
(>0 to 100) °C
(>100 to 300) °C
(300 to 400) °C
(>400 to 630) °C
(-200 to -190) °C
(>-190 to -80) °C
(>-80 to 0) °C
(>0 to 100) °C
(>100 to 260) °C
(>260 to 300) °C
(>300 to 400) °C
(>400 to 600) °C
(>600 to 630) °C
(-200 to 100) °C
(>100 to 260) °C
(>260 to 300) °C
(>300 to 400) °C
(>400 to 600) °C
(>600 to 630) °C
(-200 to -80) °C
(>-80 to 100) °C
(>100 to 260) °C
(>260 to 400) °C
(>400 to 600) °C
(>600 to 630) °C
(-200 to 0) °C
(>0 to 100) °C
(>100 to 260) °C
(>260 to 300) °C
(>300 to 600) °C
(>600 to 630) °C
(-80 to 100) °C
(>100 to 260) °C
(-100 to 260) °C
0.042 °C
0.055 °C
0.071 °C
0.079 °C
0.095 °C
0.18 °C
0.045 °C
0.059 °C
0.072 °C
0.079 °C
0.095 °C
0.19 °C
0.032 °C
0.041 °C
0.049 °C
0.056 °C
0.065 °C
0.072 °C
0.079 °C
0.18 °C
0.033 °C
0.043 °C
0.095 °C
0.10 °C
0.11 °C
0.13 °C
0.032 °C
0.041 °C
0.050 °C
0.063 °C
0.071 °C
0.086 °C
0.027 °C
0.032 °C
0.040 °C
0.048 °C
0.055 °C
0.18 °C
0.063 °C
0.11 °C
0.12 °C
Fluke 5522A
4 wire compensation | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 14 of 16
IV. Mechanical
Parameter/Equipment
Range
CMC2, 5, 8 (±)
Comments
Pressure – Measuring
Equipment & Measure
Hydraulic
Pneumatic
Vacuum
(10 to 500) psig
(500 to 10 000) psig
Up to 500 psig
Up to 15 inHg
(>15 to 27) inHg
0.047 %
0.031 %
0.13 %
0.10 %
0.68 %
Fluke P3124-3
Dwyer DCG II-107
Additel ADT681
Scales & Balances
(0.05 to 0.2) oz
(>0.2 to 8) oz
(1 to 2) lb
(>2 to 50) lb
(>50 to 500) lb
(1 to 2) g
(>2 to 20) g
>20 g to 5 kg
0.081 % + 0.6R
0.024 % + 0.6R
0.020 % + 0.6R
0.010 % + 0.6R
0.008 % + 0.6R
0.20 % + 0.6R
0.042 % + 0.6R
0.024 % + 0.6R
Class F weights
Torque – Measure6
(4 to 50) lbf·in
(30 to 400) lbf·in
(80 to 1000) lbf·in
(20 to 250) lbf·ft
0.12 %
0.12 %
0.064 %
0.052 %
CDI 5000ST
w/ 2000-400-02
Torque – Measuring
Equipment
(5 to 100) lbf·in
10 lbf·in to 250 lbf·ft
0.017 %
0.036 %
Lever arms &
traceable hanging
weights
Force – Measure &
Measuring Equipment
Compression & Tension
(10 to <500) lbf
(500 to 2000) lbf
0.21 lbf
0.66 lbf
Comparison w/
standard load cell
RPM – Measuring
Equipment
Optical
(1 to 1000) RPM
(1000 to 99 000) RPM
0.035 RPM
1.2 RPM
Keysight 33622A w/
GPS reference &
LED fixture
RPM – Measure
Non-Contact
(6 to 10 000) RPM
(10 000 to 99 000) RPM
0.89 RPM
2.4 RPM
Shimpo 207LT | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 15 of 16
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 5, 8 (±)
Comments
Temperature – Measure
(-190 to 100) °C
(>100 to 500) °C
(-70 to 180) °C
0.04 °C
0.11 °C
0.09 °C + 0.60R
Fluke 1524 w/ 5609
Vaisala HMP77
Humidity – Generate &
Measure
Up to 25 °C
(>25 to 40) °C
Up to 30 % RH
(>30 to <85) % RH
85% RH
Up to 35 % RH
1.6 % RH
1.4 % RH
1.9 % RH
1.6 % RH
Vaisala HMP77
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 5, 8 (±)
Comments
Frequency – Generate
10 MHz
10 Hz to 1 GHz
10 mHz to 120 MHz
2.5 x 10-12 Hz
2.5 x 10
-12 Hz + 5 µHz
2.5 x 10-12 Hz
GPS reference
5522A w/ GPS
reference
33622A w/ GPS
reference
Frequency – Measure
Up to 2 kHz
(>2 to 200) kHz
>200 kHz to 20 MHz
(>20 to 100) MHz
(>100 to 350) MHz
0.16 nHz
5.2 nHz
1.1 µHz
3.8 µHz
0.24 mHz
Frequency counters
w/ external
reference
Stopwatches & Timers
Up to 24 hr
0.02 sec/day + 0.60R
Timometer
_____________________________
1 This laboratory is not normally available for commercial calibration service. | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5918.01) 4/17/2025 Page 16 of 16
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
R is the resolution of the unit under test, and % is defined as percent of reading unless otherwise noted.
6 The contributions from the “best existing device” are not included in the CMC claim.
7 The measurands stated are generated using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges
indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the
reading plus a fixed floor specification.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 17 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.