Registers refreshed 2026-11-20.See refresh dates
Mexico

BCS Automotive Interface Solutions

Parque Industrial PYME, Calle Industria Energética Lote 1, Manzana 2., El Colorado, Municipio de el Marques, C.P., Queretaro, 76246, Mexico, Queretaro, Mexico

A2LA 2120.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 5 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 12103-1Road vehicles - Test contaminants for filter evaluation - Part 1: Arizona test dust
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
ISO 16750-5Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 5: Chemical loads
ISO 60068-2-27

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

2 lines
A2LA

ISO/IEC 17025

Active

2120.02

The scope document we hold says it was valid until 2026-01-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 2120.02

LineMethodMatrixRange
1ISO/IEC 17025:2017; ISO 16750-4; ISO 16750-3; ISO 60068-2-27 Dust ISO 12103-1; ISO 16750-5 1automobile components-50 to 125 °C
2ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Parque Industrial PYME, Calle Industria Energética Lote 1, Manzana 2., El Colorado, Municipio de el Marques, C.P., Queretaro, 76246, Mexico, Queretaro, MX

20.80522, -99.88374

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.