Shenzhen Huaxin Information Technology Service Co.,LTD
101, R&D Building, No.3 guansheng 4th Road, Luhu Community, Guanhu Street, Longhua District, Shenzhen, Guangdong, China, Shenzhen, People's Republic of China, Shenzhen, China
- Accredited standards
- 58
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 58 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI32
ETSI EN 300 113
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 422-1
ETSI EN 300 422-2
ETSI EN 300 422-3
ETSI EN 300 422-4
Show all 32
ETSI EN 300 440
ETSI EN 301 357
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-34
ETSI EN 301 489-50
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 446-1
ETSI EN 303 446-2
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.4identical to it
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS CISPR 14.1national version with changes
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national
National versions in the same scope
AS/NZS CISPR 14-2probably the same standard; matched by number only
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national
National versions in the same scope
AS CISPR 15national version with changes
AS/NZS CISPR 15national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC4
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
EN 50364
FCC PART 15Radio Frequency Devices
EN 300 328; EN 301 893; EN 300 220-1; EN 300 220-2; EN 300 220-3-1; EN 300 220-3-2; EN 300220-4; EN 300 440; EN 300 330; EN 300 422-1; EN 300 422-2; EN 300 422-3; EN 300 422-4; EN 303 413; EN 301 357; EN 303 417; AS/NZS 4268; CFR 47, FCC Parts 22, 24, 25, 27; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-119; RSS-199; MIC notification. No.88; EN 300 113; EN 301 511; ETSI EN 301 908-1; EN 301 908-2; EN 301 908-13; SPR-002; BS EN 62311; IEC 62311; EN 62311; EN IEC 62311; BS EN 62479; IEC 62479; EN 62479; AS/NZS 2772.2; BS EN 50364; EN 50364
BS EN 61000-4-6; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-8; EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-11; BS EN IEC 61000-4-11; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN 55014-2; EN 55014-2; CISPR 14-2; AS/NZS CISPR 14-2; EN 62040-2; BS EN 61547; IEC 61547; EN 61547; BS EN 55035; EN 55035; CISPR 35; BS EN 61000-6-1; BS EN IEC 61000-6-1; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; BS EN IEC 61000-6-2; IEC 61000-6-2; EN IEC 61000-6-2; BS EN 61000-6-3; IEC 61000-6-3; EN 61000-6-3; AS/NZS 61000.6.3; BS EN IEC 61000-6-4; IEC 61000-6-4; EN IEC 61000-6-4; AS/NZS 61000.6.4; EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-9; EN 301 489-17; EN 301 489-19; EN 301 489-34; EN 301 489-50; EN 301 489-52; EN 303 446-1; EN 303 446-2; CFR 47, FCC Part 15, Subpart C; ANSI C63.10-2013; CFR 47, FCC Part 15, Subpart E; FCC KDB 905462 D02 (v02); RSS-210; RSS-247; RSS-216; RSS-310; RSS-GEN
CFR 47, FCC Part 15, Subpart B; ANSI C63.4-2014; CFR 47, FCC Part 18; FCC MP-5 (1986); ICES-001; ICES-003; ICES-005; RSS-GEN; AS CISPR 11; BS EN 55011; EN 55011; CISPR 11; J55011; BS EN IEC 55014-1; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; J55014-1; BS EN IEC 55015; EN IEC 55015; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; J55015; BS EN 55032; EN 55032; CISPR 32; AS/NZS CISPR 32; J55032; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; BS EN IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; BS EN IEC 61000-3-3; BS EN 61000-4-2; IEC 61000-4-2; EN 61000-4-2; BS EN IEC 61000-4-3; EN IEC 61000-4-3; IEC 61000-4-3; BS EN 61000-4-4; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-5; IEC 61000-4-5; EN 61000-4-5
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C763.26:2013
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active6855.01
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 6855.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CFR 47, FCC Part 15, Subpart B; ANSI C63.4-2014; CFR 47, FCC Part 18; FCC MP-5 (1986); ICES-001; ICES-003; ICES-005; RSS-GEN; AS CISPR 11; BS EN 55011; EN 55011; CISPR 11; J55011; BS EN IEC 55014-1; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; J55014-1; BS EN IEC 55015; EN IEC 55015; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; J55015; BS EN 55032; EN 55032; CISPR 32; AS/NZS CISPR 32; J55032; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; BS EN IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; BS EN IEC 61000-3-3; BS EN 61000-4-2; IEC 61000-4-2; EN 61000-4-2; BS EN IEC 61000-4-3; EN IEC 61000-4-3; IEC 61000-4-3; BS EN 61000-4-4; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-5; IEC 61000-4-5; EN 61000-4-5 | - | - |
| 2 | BS EN 61000-4-6; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-8; EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-11; BS EN IEC 61000-4-11; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN 55014-2; EN 55014-2; CISPR 14-2; AS/NZS CISPR 14-2; EN 62040-2; BS EN 61547; IEC 61547; EN 61547; BS EN 55035; EN 55035; CISPR 35; BS EN 61000-6-1; BS EN IEC 61000-6-1; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; BS EN IEC 61000-6-2; IEC 61000-6-2; EN IEC 61000-6-2; BS EN 61000-6-3; IEC 61000-6-3; EN 61000-6-3; AS/NZS 61000.6.3; BS EN IEC 61000-6-4; IEC 61000-6-4; EN IEC 61000-6-4; AS/NZS 61000.6.4; EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-9; EN 301 489-17; EN 301 489-19; EN 301 489-34; EN 301 489-50; EN 301 489-52; EN 303 446-1; EN 303 446-2; CFR 47, FCC Part 15, Subpart C; ANSI C63.10-2013; CFR 47, FCC Part 15, Subpart E; FCC KDB 905462 D02 (v02); RSS-210; RSS-247; RSS-216; RSS-310; RSS-GEN | - | - |
| 3 | EN 300 328; EN 301 893; EN 300 220-1; EN 300 220-2; EN 300 220-3-1; EN 300 220-3-2; EN 300220-4; EN 300 440; EN 300 330; EN 300 422-1; EN 300 422-2; EN 300 422-3; EN 300 422-4; EN 303 413; EN 301 357; EN 303 417; AS/NZS 4268; CFR 47, FCC Parts 22, 24, 25, 27; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-119; RSS-199; MIC notification. No.88; EN 300 113; EN 301 511; ETSI EN 301 908-1; EN 301 908-2; EN 301 908-13; SPR-002; BS EN 62311; IEC 62311; EN 62311; EN IEC 62311; BS EN 62479; IEC 62479; EN 62479; AS/NZS 2772.2; BS EN 50364; EN 50364 | - | - |
| 4 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C763.26:2013 | - | to 40000 MHz |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SHENZHEN HUAXIN INFORMATION TECHNOLOGY
SERVICE CO., LTD
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 27th day of May 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6855.01
Valid to May 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014EN 300 328
- Dongguan New Testing Centre Co.,DongguanA2LAShares 2 accredited test methodsANSI C63.4:2014EN 300 328
- EST Technology Co.,Dongguan, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014EN 300 328
- Guangdong Dongdian Testing Service Co.,Dongguan City, Guangdong ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014EN 61000-4-6
- SGS-CSTC Standards Technical Services (Suzhou) Co.,SuzhouA2LAShares 2 accredited test methodsANSI C63.4:2014EN 300 328
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.