United States

Instrument Technologies

Boise, ID, United States

Visit website
A2LA 3316.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 3316.01 · 15 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 1 of 14 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 INSTRUMENT TECHNOLOGIES, INC. 254 S Cole Boise, ID 83709 Brett Bohannon Phone: 208 860 3981 CALIBRATION Valid To: July 31, 2026 Certificate Number: 3316.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Chemical Parameter/Equipment Range CMC2, 4, 7 (±) Comments CO2 – Measure3 (0 to 4) % CO2 (4 to 6) % CO2 (6 to 10) % CO2 0.31 % CO2 0.35 % CO2 0.45 % CO2 Vaisala GMP 221 Gas Detection Equipment 3 – CO2 5 % CO2 10 % CO2 0.06 % CO2 0.11 % CO2 Reference CO2 gas – EPA protocol pH Meters 4 pH 7 pH 10 pH 0.012 pH 0.013 pH 0.017 pH Standard solutions Conductivity Meters 1 µS/cm 5 µS/cm 10 µS/cm 100 µS/cm 1000 µS/cm 1413 µS/cm 10 mS/cm 100 mS/cm 150 mS/cm 200 mS/cm 0.30 µS/cm 0.30 µS/cm 0.30 µS/cm 1.0 µS/cm 3.3 µS/cm 3.7 µS/cm 38 µS/cm 350 µS/cm 700 µS/cm 750 µS/cm Standard solutions
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 2 of 14 Parameter/Equipment Range CMC2 (±) Comments Conductivity Meters (cont) 1 µS/cm 10 µS/cm 100 µS/cm 1000 µS/cm 10 mS/cm 100 mS/cm 0.0013 µS/cm 0.013 µS/cm 0.13 µS/cm 1.3 µS/cm 0.013 mS/cm 0.13 mS/cm Standard resistors II. Dimensional Parameter/Equipment Range CMC2, 7 (±) Comments Angle Indicator3 (Wave Bioreactor) – Measure (0 to 10)° (10 to 90)° 0.22° 0.29° Mitutoyo Pro 360 III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Current – Measure3 Up to 200 µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (2 to 50) A 12 µA/A + 0.4 nA 12 µA/A + 4 nA 13 µA/A + 40 nA 36 µA/A + 0.8 µA 0.017 % + 16 µA 0.038 % + 0.4 mA 0.012 % Fluke 8508A Fluke 8508A Fluke 8508A w/ Ohm Labs CS-50 shunt DC Current – Generate3 (0 to 330) µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 2.3) A (2.3 to 11) A (11 to 20.5) A 0.015 % + 20 nA 0.01 % + 50 nA 0.01 % + 250 nA 0.01 % + 2.5 µA 0.02 % + 40 µA 0.038 % + 40 µA 0.05 % + 500 µA 0.1 % + 750 µA Fluke 5522A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 3 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Measure3 Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V 4.5 µV/V + 110 nV 3.0 µV/V + 500 nV 3.0 µV/V + 4 µV 4.5 µV/V + 50 µV 4.5 µV/V + 500 µV Fluke 8508A DC Voltage– Generate3 (0 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1020) V 20 µV/V + 1 µV 11 µV/V + 2 µV 12 µV/V + 20 µV 18 µV/V + 150 µV 18 µV/V + 1.5 mV Fluke 5522A Resistance – Measure3 Up to 2 Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ 15 µΩ/Ω + 5 µΩ 9 µΩ/Ω + 16 µΩ 7.5 µΩ/Ω + 50 µΩ 7.5 µΩ/Ω + 0.5 mΩ 7.5 µΩ/Ω + 5 mΩ 7.5 µΩ/Ω + 50 mΩ 8.5 µΩ/Ω + 1 Ω 15 µΩ/Ω + 100 Ω 60 µΩ/Ω + 10 kΩ 0.053 % + 1 MΩ Fluke 8508A Resistance – Generate3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω 110 Ω to 1.1 kΩ (1.1 to 11) kΩ (11 to 110) kΩ 110 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 40 µΩ/Ω + 0.001 Ω 30 µΩ/Ω + 0.0015 Ω 28 µΩ/Ω + 0.0014 Ω 28 µΩ/Ω + 0.002 Ω 28 µΩ/Ω + 0.02 Ω 28 µΩ/Ω + 0.2 Ω 32 µΩ/Ω + 2 Ω 60 µΩ/Ω + 30 Ω 0.013 % + 50 Ω 0.025 % + 2.5 kΩ 0.05 % + 3 kΩ 0.3 % + 100 kΩ 1.5 % + 500 kΩ Fluke 5522A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 4 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure3 Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V (1 to 10) Hz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 10) Hz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 0.1 % + 100 µV 0.1 % + 100 µV 0.025 % + 50 µV 0.011 % + 4 µV 0.011 % + 2 µV 0.011 % + 4 µV 0.031 % + 8 µV 0.071 % + 20 µV 0.014 % + 120 µV 0.011 % + 20 µV 85 µV/V + 20 µV 65 µV/V + 20µV 85 µV/V + 20 µV 0.021 % + 40 µV 0.051 % + 200 µV 0.3 % + 2 mV 1 % + 20 mV 0.014 % + 1.2 mV 0.011 % + 200 µV 85 µV/V + 200 µV 65 µV/V + 200 µV 85 µV/V + 200 µV 0.021 % + 400 µV 0.051 % + 2 mV 0.3 % + 20 mV 1 % + 200 mV 0.014 % + 12 mV 0.011 % + 2 mV 85 µV/V + 2 mV 65 µV/V + 2 mV 85 µV/V + 2 mV 0.021 % + 4 mV 0.051 % + 20 mV 0.3 % + 200 mV 1 % + 2 V 0.014 % + 70 mV 0.011 % + 20 mV 95 µV/V + 20 mV 0.021 % + 40 mV 0.051 % + 200 mV Fluke 8508A
to 1000 V
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 5 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.08 % + 23 µV 0.015 % + 6 µV 0.02 % + 6 µV 0.1 % + 6 µV 0.35 % + 12 µV 0.8 % + 50 µV 0.2 % + 8 µV 0.03 % + 8 µV 0.015 % + 8 µV 0.016 % + 8 µV 0.035 % + 8 µV 0.08 % + 32 µV 0.2 % + 70 µV 0.03 % + 50 µV 0.015 % + 60 µV 0.019 % + 60 µV 0.03 % + 50 µV 0.07 % + 130 µV 0.24 % + 600 µV 0.03 % + 650 µV 0.015 % + 600 µV 0.024 % + 600 µV 0.035 % + 600 µV 0.09 % + 1.6 mV 0.019 % + 2 mV 0.02 % + 6 mV 0.025 % + 6 mV 0.03 % + 6 mV 0.2 % + 50 mV 0.03 % + 10 mV 0.025 % + 10 mV 0.03 % + 10 mV Fluke 5522A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 6 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate3 (29 to 330) µA 300 µA to 3.3 mA (3.3 to 33.3) mA (33.3 to 330) mA 330 mA to 1.1 A (1.1 to 3.0) A (3.0 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.2 % + 100 nA 0.15 % + 100 nA 0.13 % + 100 nA 0.3 % + 150 nA 0.8 % + 200 nA 1.6 % + 400 nA 0.2 % + 150 nA 0.13 % + 150 nA 0.1 % + 150 nA 0.2 % + 200 nA 0.5 % + 300 nA 1.0 % + 600 nA 0.18 % + 2 µA 0.09 % + 2 µA 0.04 % + 2 µA 0.08 % + 2 µA 0.2 % + 3 µA 0.4 % + 4 µA 0.18 % + 20 µA 0.09 % + 20 µA 0.04 % + 20 µA 0.10 % + 50 µA 0.2 % + 100 µA 0.4 % + 200 µA 0.18 % + 100 µA 0.05 % + 100 µA 0.6 % + 1 mA 2.5 % + 5 mA 0.18 % + 100 µA 0.06 % + 100 µA 0.6 % + 1 mA 2.5 % + 5 mA 0.06 % + 2 mA 0.1 % + 2 mA 3.0 % + 2 mA 0.12 % + 5 mA 0.15 % + 5 mA 3.0 % + 5 mA Fluke 5522A
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 7 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure3 Up to 200 µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 50) A 1 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz (1 to 10) Hz (10 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 20) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 20) kHz 0.048 % + 20 nA 0.065 % + 20 nA 0.4 % + 20 nA 0.029 % + 200 nA 0.028 % + 200 nA 0.065 % + 200 nA 0.4 % + 200 nA 0.029 % + 2 µA 0.028 % + 2 µA 0.065 % + 2 µA 0.4 % + 2 µA 0.029 % + 20 µA 0.025 % + 20 µA 0.06 % + 20 µA 0.06 % + 200 µA 0.071 % + 200 µA 0.3 % + 200 µA 0.08 % + 2 mA 0.25 % + 2 mA 0.022 % + 1.6 mA 0.022 % + 5 mA 0.022 % + 2.4 mA 0.022 % + 5 mA 0.025 % + 10 mA 0.022 % + 14 mA 0.022 % + 2.4 mA 0.024 % + 5 mA Fluke 8508A Fluke 8508A w/ Ohm Labs CS-50 shunt Distortion – Measure3 (-99.9 to 0) dB 20 Hz to 20 kHz 1.1 dB Keithley 2015
to 200 µA
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 8 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Capacitance – Generate3 (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.5 % + 10 pF 0.5 % + 0.01 nF 0.5 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.03 nF 0.25 % + 1 nF 0.25 % + 3 nF 0.25 % + 10 nF 0.40 % + 30 nF 0.45 % + 100 nF 0.45 % + 300 nF 0.45 % + 1 µF 0.45 % + 3 µF 0.45 % + 10 µF 0.75 % + 30 µF 1.1 % + 100 µF Fluke 5522A Electrical Calibration of Thermocouples – Generate & Measure3 Type B Type E Type J Type K Type N (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (-250 to -100) °C (-100 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 410) °C (410 to 1300) °C 0.35 °C 0.27 °C 0.24 °C 0.26 °C 0.40 °C 0.13 °C 0.17 °C 0.22 °C 0.14 °C 0.18 °C 0.26 °C 0.15 °C 0.21 °C 0.32 °C 0.32 °C 0.19 °C 0.22 °C Fluke 5522A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 9 of 14 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples – Generate & Measure3 (cont) Type R Type S Type T Type U (0 to 250) °C (250 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 400) °C (-200 to 0) °C (0 to 600) °C 0.45 °C 0.28 °C 0.32 °C 0.39 °C 0.29 °C 0.36 °C 0.50 °C 0.19 °C 0.13 °C 0.44 °C 0.22 °C Fluke 5522A IV. Fluid Quantities Parameter/Equipment Range CMC2, 4, 7 (±) Comments Flow Rate – Measure Liquid Mass Flow3 Liquid Volume Flow 3 Liquid Mass Flow (15 to 4000) g/min (0 to 250) g/min (250 to 7500) g/min (0 to 9) kg/min (9 to 300) kg/min (0 to 250) ml/min (250 to 7500) ml/min (0 to 9) l/min (9 to 300) l/min (0 to 3200) g 0.5 g/min 0.21 % 15 g/min 0.17 % 0.5 ml/min 0.21 % 15 ml/min 0.17 % 0.63 g Endress & Hauser Promass Coriolis flow meters Endress & Hauser Promass Coriolis flow meters Gravimetric flow bench with balance
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 10 of 14 Parameter/Equipment Range CMC2, 4, 7 (±) Comments Gas Flow Rate – Measuring Equipment (500 to 50,000) sccm (0 to 10) slpm (10 to 20) slpm (20 to 50) slpm (50 to 100) slpm 0.23 % 0.62 % + 0.024 slpm 0.62 % + 0.048 slpm 0.62 % + 0.12 slpm 0.62 % + 0.24 slpm Mesa Dry-Cal Mass flow meters V. Mechanical Parameter/Equipment Range CMC2, 4, 7 (±) Comments Pneumatic/Hydraulic Gage Pressure – Measuring Equipment3 (0 to 0.25) in·H2O (0 to 3) in·H2O (0 to 15) in·H2O (0 to 25) in·H2O (0 to 60) psig (0 to 100) psig (0 to 300) psig (0 to 600) psig (0 to 1000) psig (0 to 9) psig (9 to 30) psig (0 to 90) psig (90 to 300) psig (0 to 11) in·H 2O (11 to 415) in·H2O (100 to 15 000) psig 0.000 48 in·H2O 0.0027 in·H2O 0.011 in·H2O 0.031 in·H2O 0.019 psig 0.060 psig 0.090 psig 0.19 psig 0.31 psig 0.0028 psig 0.03 % 0.03 psig 0.031 % 0.0048 in·H 2O 0.42 % 0.01 % + 0.015 psig Heise ST-2H / HQS-1 Heise ST-2H / HQS-2 Crystal/Ametek APM30PSI Crystal/Ametek AMP300PSI Crystal/Ametek HPC52 Ametek T-150 Pneumatic Absolute Pressure – Measuring Equipment3 Up to 15 psia 0.0061 psia Heise ST-2H / HQS-2 Vacuum – Measuring Equipment3 Up to 30 in·Hg 0.013 in·Hg Heise ST-2H / HQS-2
500 to 50000 sccm
11ASTM Class 1; OIML Class F1-See scope document
12ASTM Class 1; ASTM Class 6; ASTM Class 2Scales & Balances; Liquid flowSee scope document
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 13 of 14 Parameter/Equipment Range CMC2, 7 (±) Comments Temperature – Measuring Equipment3 -196 °C (-95 to -80) °C (-80 to -20) °C (-20 to 100) °C (100 to 200) °C (200 to 650) °C 0.013 °C 0.019 °C 0.018 °C 0.025 °C 0.033 °C 0.13 °C Hart Scientific 5628 w/ Hart Scientific 1502A with LN 2, dry ice / ethanol slurry & baths Controlled Temperature Units – Measure 3 Refrigerators -20 °C Freezers -80 °C Freezers Cryo Freezers Incubators Glass Washers, Ovens, & Furnaces (2 to 8) °C (-30 to -10) °C (-90 to -60) °C (-196 to -120) °C (0 to 65) °C (0 to 260) °C (260 to 660) °C 0.25 °C 0.27 °C 0.30 °C 0.52 °C 0.22 °C 0.85 °C 2.4 °C RTD w/ temperature readout Thermocouple w/ temperature readout Relative Humidity – Measure3 Up to 90 % RH (90 to 100) % RH 1.4 % RH 2.1 % RH Vaisala HMP77B Relative Humidity – Measuring Equipment LiCl 11 % RH MgCl2 33 % RH NaCl 75 % RH K2SO4 97 % RH 0.57 % RH 0.90 % RH 0.95 % RH 1.2 % RH Salt solutions VII. Time & Frequency Parameter/Equipment Range CMC2, 4, 7 (±) Comments Frequency – Measuring Equipment3 100 µHz to 15 MHz 0.01 Hz to 2 MHz 24 µHz/Hz 2 µHz/Hz + 5 µHz Agilent 33120A Fluke 5522A Frequency – Measure3 10 Hz to 1 MHz 12 parts in 106 Hz + 2 digits Fluke 8508A Time – Measure3 1 s to 9:59:59:99 hr 0.001 % + 67 ms Control Company 1221
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3316.01) Revised 1/06/2026 Page 14 of 14 _____________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted. In the statement of CMC, R is resolution of the unit under test. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
15

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited INSTRUMENT TECHNOLOGIES, INC. Boise, ID for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 17th day of October 2024. _______________________ Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3316.01 Valid to July 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.