Friedrich-Alexander-Universität Erlangen-Nürnberg Institut für Rechtsmedizin
Universitätsstraße 22, 91054, Erlangen, Germany
- Scope lines
- 11
- DAKKS certificates
- 4
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
DAKKS certificate D-PL-17960-01-00 · 2 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001; DIN EN ISO/IEC 17011 | - | - |
| 2 | DIN EN ISO/IEC 17000 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
DAKKS certificate D-PL-17960-01-01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-17960-01-01
Gültig ab: 02.09.2025 Gültig bis: 01.09.2030
Ausstellungsdatum: 02.09.2025 Seite 2 von 4
Prüfungen im Bereich:
Forensik
Prüfgebiet:
1 Forensische Genetik ............................. ............................................................................................. 3
Flexibler Akkreditierungsbereich:
Dem Prüflaboratorium ist innerhalb der gekennzeichneten Prüfbereiche, ohne dass es einer
vorherigen Information und Zustimmung der DAkkS bedarf,
[Flex C] die Modifizierung sowie Weiter- und Neuen twicklung von Prüfverfahren gestattet .
Die aufgeführten Prüfverfahren sind beispielhaft. Das Prüflaboratorium verfügt über eine aktuelle
Liste aller Prüfverfahren im flexiblen Akkreditierungsbereich. Die Liste ist öffentlich verfügbar auf
der Webpräsenz des Prüflaboratoriums. | ||
| 3 | - | UrineShow page textExtracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-17960-01-01
Gültig ab: 02.09.2025 Gültig bis: 01.09.2030
Ausstellungsdatum: 02.09.2025 Seite 3 von 4
1 Forensische Genetik
Prüfart -
Prüfmethodik/Messprinzip
Analyt/ Messgröße/
Prüfparameter/
Matrix/ Testobjekt
Prüfgegenstand
Geltungsbereich
Probenahme
Probe nahme im Rahmen der
Spurenuntersuchung
Humanbiolo -
gisches Material,
Gewebe
[Flex C]
Probe nahme im Rahmen der
Vergleichsuntersuchung
Mundschleimhaut [Flex C]
Probe nahme im Rahmen der
Identitätsfeststellung
Mundschleimhaut,
humanbiolo-
gisches Material,
Gewebe
[Flex C]
Vortests
chemische Testverfahren
Blut Humanbiologische
Probe
[Flex C]
Vortests
immunochemische
Testverfahren
Blut Humanbiologische
Probe
[Flex C]
Vortests
Enzymatische Testverfahren
Speichel Humanbiologische
Probe
[Flex C]
Vortests
immunochemische Test-
verfahren
Speichel Humanbiologische
Probe
[Flex C]
Vortests
Enzymatische Testverfahren
Sperma Humanbiologische
Probe
[Flex C]
Vortests
immunochemische Test-
verfahren
Sperma Humanbiologische
Probe
[Flex C]
Vortests
histochemische
Färbeverfahren,
Mikroskopie
Sperma Humanbiologische
Probe
[Flex C]
Vortests
Enzymatische Testverfahren
Urin Humanbiologische
Probe
[Flex C]
Polymerase -Kettenreaktion
mit flexiblen Reagenzien
DNA-Extraktion,
Quantifizierung mit RT-PCR,
STR-PCR, Elektrophorese,
allelische Zuordnung der
PCR-Produkte
Genotyp zur
Spurenuntersuchung,
Vergleichsprobenuntersuch
ung, Identitätsfeststellung
Mundschleimhaut,
Blut, Human-
material,
forensische
Spuren, Gewebe
[Flex C]
Verwendete Abkürzungen: | - |
| 4 | DIN; EN; IEC; ISO | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
DAKKS certificate D-PL-17960-02-00 · 2 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO/IEC 17011 | - | - |
| 2 | DIN EN ISO/IEC 17000 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
DAKKS certificate D-PL-17960-02-01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-17960-02-01
Gültig ab: 01.09.2025 Gültig bis: 31.08.2030
Ausstellungsdatum: 01.09.2025 Seite 2 von 3
Prüfungen im Bereich:
Forensik
Prüfgebiet:
1 Forensische Genetik ............................. ............................................................................................. 3
Flexibler Akkreditierungsbereich:
Dem Prüflaboratorium ist innerhalb der gekennzeichneten Prüfbereiche, ohne dass es einer
vorherigen Information und Zustimmung der DAkkS bedarf,
[Flex C] die Modifizierung sowie Weiter- und Neuen twicklung von Prüfverfahren gestattet .
Die aufgeführten Prüfverfahren sind beispielhaft. Das Prüflaboratorium verfügt über eine aktuelle
Liste aller Prüfverfahren im flexiblen Akkreditierungsbereich. Die Liste ist öffentlich verfügbar auf
der Webpräsenz des Prüflaboratoriums. | ||
| 3 | GenDG | Mundschleimhaut; Blut; Gewebe | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- ELAB AnalytikSiegen · ~258 kmDAKKSShares 3 accredited methods and materialsEN ISO 9001DINUrine
- LADR GmbH Medizinisches Versorgungszentrum Dr. Kramer und KollegenGeesthacht · ~429 kmDAKKSShares 3 accredited methods and materialsEN ISO 9001DINUrine
- Analytik Institut Rietzler GmbH Laborstandort und Emissionsmessstelle FürthFürth · ~14 kmDAKKSShares 2 accredited test methodsEN ISO 9001DIN
- CompetenzaFürth · ~15 kmDAKKSShares 2 accredited test methodsEN ISO 9001DIN
- Lynexo DeutschlandNürnberg · ~15 kmDAKKSShares 2 accredited test methodsEN ISO 9001DIN
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.