What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 25 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
KS C 9610-3-2national version with changes
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
KS C 9610-3-3national version with changes
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national
National versions in the same scope
KS C 9610-4-5national version with changes
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
KS C 9610-4-6national version with changes
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-8national version with changes
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
KS C 9610-4-11probably the same standard; matched by number only
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
KS C 9610-6-1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
KS C 9610-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-4national version with changes
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
KS C 9814-1national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national
National versions in the same scope
KS C 9835national version with changes
IEC3
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests+1 national
National versions in the same scope
KS C IEC 60601-1-2probably the same standard; matched by number only
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
FCC PART 15Radio Frequency Devices
IEC 61000-3-2; EN 61000-3-2; KS C 9610-3-2; IEC 61000-3-3; EN 61000-3-3; KS C 9610-3-3; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6; IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11; CISPR 24; EN 55024; CISPR 35; EN 55035; KS C 9835; EN 50130-4; IEC 60730-1; IEC 61326; EN 61326; IEC 61326-1; EN 61326-1; IEC 60601-1-2; EN 60601-1-2; KS C IEC 60601-1-2; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; FCC CFR 47, Part 15 Subparts C, E, F, G, and H; ANSI C63.10; FCC CFR 47, Part 15, Subpart D; ANSI 63.17; RSS-GEN; RSS-210; RSS-213; RSS-247; IEEE/ANSI C95.3
FCC CFR 47, Part 15, Subpart B (using ANSI C63.4); FCC CFR 47, Part 18 (using MP-5:1986); CISPR 11; EN 55011; KS C 9811; AS CISPR 11; CNS 13438; CISPR 13; EN 55013; CISPR 14; EN 55014-1; KS C 9814-1; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; KS C 9832; AS/NZS CISPR 32; IEC 61326-1; EN 61326-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; ICES-001; ICES-003; ICES-005; VCCI-CISPR 32:2016; VCCI V-3; ANSI C63.4
FCC CFR 47, Part 15, Subpart B (using ANSI C63.4); FCC CFR 47, Part 18 (using MP-5:1986); CISPR 11; EN 55011; KS C 9811; AS CISPR 11; CISPR 13; EN 55013; CISPR 14-1; EN 55014-1; KS C 9814-1; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; KS C 9832; AS/NZS CISPR 32; CNS 13438; IEC 61326-1; EN 61326-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; ICES-001; ICES-003; ICES-005; VCCI-CISPR 32:2016; VCCI V-3; ANSI C63.4
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.17:2013
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active2569.01
The scope document we hold says it is valid until 2027-06-30.
Accredited scope, certificate 2569.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | FCC CFR 47, Part 15, Subpart B (using ANSI C63.4); FCC CFR 47, Part 18 (using MP-5:1986); CISPR 11; EN 55011; KS C 9811; AS CISPR 11; CNS 13438; CISPR 13; EN 55013; CISPR 14; EN 55014-1; KS C 9814-1; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; KS C 9832; AS/NZS CISPR 32; IEC 61326-1; EN 61326-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; ICES-001; ICES-003; ICES-005; VCCI-CISPR 32:2016; VCCI V-3; ANSI C63.4 | - | to 40 GHz |
| 2 | IEC 61000-3-2; EN 61000-3-2; KS C 9610-3-2; IEC 61000-3-3; EN 61000-3-3; KS C 9610-3-3; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6; IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11; CISPR 24; EN 55024; CISPR 35; EN 55035; KS C 9835; EN 50130-4; IEC 60730-1; IEC 61326; EN 61326; IEC 61326-1; EN 61326-1; IEC 60601-1-2; EN 60601-1-2; KS C IEC 60601-1-2; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; FCC CFR 47, Part 15 Subparts C, E, F, G, and H; ANSI C63.10; FCC CFR 47, Part 15, Subpart D; ANSI 63.17; RSS-GEN; RSS-210; RSS-213; RSS-247; IEEE/ANSI C95.3 | - | to 40 GHz |
| 3 | FCC CFR 47, Part 15, Subpart B (using ANSI C63.4); FCC CFR 47, Part 18 (using MP-5:1986); CISPR 11; EN 55011; KS C 9811; AS CISPR 11; CISPR 13; EN 55013; CISPR 14-1; EN 55014-1; KS C 9814-1; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; KS C 9832; AS/NZS CISPR 32; CNS 13438; IEC 61326-1; EN 61326-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; ICES-001; ICES-003; ICES-005; VCCI-CISPR 32:2016; VCCI V-3; ANSI C63.4 | materials and products | to 18 GHz |
| 4 | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.17:2013 | - | See scope document |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
ELECTROMAGNETIC INVESTIGATIONS, LLC
Hillsboro, OR
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 3rd day of June 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2569.01
Valid to June 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Element Materials Technology Seattle - Bothell 120thBothell, WA · ~256 kmA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 61000-3-2
- CETECOMMilpitas, CA · ~901 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- HCT AmericaMilpitas, CA · ~904 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Vista Laboratories, Inc.San Clemente, CA · ~1,421 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Intertek Testing Services NAFridley, MN · ~2,312 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
Accreditation data refreshed from the A2LA register on .