Universal Calibrations
4878 Susanna Woods Ct, 32257, Jacksonville, FL, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 3359.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3359.01) Revised 08/06/2025 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
UNIVERSAL CALIBRATIONS
4878 Susanna Woods Ct.
Jacksonville, FL 32257
Eddie Armellino Phone: 516 807 1811
Michael Constantin Phone: 917 613 2287
CALIBRATION
Valid to: March 31, 2026 Certificate Number: 3359.01
In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations
1, 6:
I. Dimensional
Parameter/Equipment
Range
CMC
2, 4 (±)
Comments
Calipers3
Up to 24 in
390 µin + 0.6R
Gage blocks
Feeler/Thickness
Gages
3
Up to 0.2 in
210 µin
Micrometer
Micrometers
3
Up to 12 in
200 µin
Gage blocks
II. Mechanical
Parameter/Equipment
Range
CMC
2, 4, 5, 7 (±)
Comments
Force
3 – Measure
(50 to 5000) lbf
(1000 to 50 000) lbf
(30 000 to 1 000 000) lbf
0.14 % + 0.60R
0.07 % + 0.60R
0.18 % + 0.60R
Morehouse 5 K load cell
Morehouse 50 K load cell
Morehouse 1000 K load
cell, ASTM E4 | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3359.01) Revised 08/06/2025 Page 2 of 3
Parameter/Equipment
Range
CMC2, 4, 5, 7 (±)
Comments
Scales
3
Up to 10 kg
Up to 300 lb
Up to 100 kg
Up to 20 000 g
3.3 µg/g + 0.60R
0.012 % + 0.60R
0.012 % + 0.60R
0.015 % + 0.60R
Class I weights
Troemner Class F weights
Vacuum & Pressure
3 –
Measuring Equipment
Pneumatic
(-15 to 300) psi
Up to 600 psi
0.95 psi
1.7 psi
Additel
ADT681-20-CP300-
PSI-N
ADT681-20-GP600-
PSI-N
III. Thermodynamics
Parameter/Equipment
Range
CMC
2, 4, 7 (±)
Comments
Electrical Calibration of
Thermocouple
Indicators
3 –
Type K
(-270 to -25) °C
(-25 to 1000) °C
(1000 to 1372) °C
0.39 °C
0.30 °C
0.47 °C
Martel 3001 calibrator
Temperature –
Measure
3
(-196 to 660) °C
0.08 °C
Martel 3001 calibrator
and AccuMac AM1760
SPRT
Temperature –
Measuring Equipment
3
(-20 to 400) °C
0.09 °C + 0.6R
Martel 3001 calibrator,
AccuMac AM1760
SPRT, and Accurate
thermal systems,
Thermcal 400 and 130
_____________________________________________
1 This laboratory offers commercial field calibrations only. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3359.01) Revised 08/06/2025 Page 3 of 3
2 Calibration and Measurement Capability Uncertain ty (CMC) is the smallest uncertainty of
measurement that a laboratory can achieve within its scope of accreditation when performing more
or less routine calibrations of nearly ideal m easurement standards or nearly ideal measuring
equipment. CMCs represent expanded uncertainti es expressed at approximately the 95 % level of
confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific
calibration performed by the laboratory may be great er than the CMC due to the behavior of the
customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement
uncertainties achievable on a customer's site can nor mally be expected to be larger than the CMC
found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place
of calibration and for other possible adverse effe cts such as those caused by transportation of the
calibration equipment. The usual allowance for the actual uncertainty introduced by the item being
calibrated, (e.g. resolution) must also be consider ed and this, on its own, could result in the actual
measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, R is the numerical value of the resolution of the device.
5 In the statement of CMC, percentages are per centage of reading, unless otherwise indicated.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments th at measure or generate the values in the ranges
indicated for the listed measurement parameter. | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
UNIVERSAL CALIBRATIONS
Mineral Bluff, GA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 3rd day of September 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3359.01
Valid to March 31, 2026 | ||
| 5 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.