Vector Measurement Services
51337 Corridor Drive, 48315, Shelby Township, MI, United States
- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 6898.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6898.01) 7/15/2024 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
VECTOR MEASUREMENT SERVICES
51337 Corridor Drive
Shelby Township, MI 48315
Dan House Phone: 586 822 5993
CALIBRATION
Valid to: July 31, 2026 Certificate Number: 6898.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations and dimensional inspections
1, 5:
I. Dimensional Testing
Parameter/Equipment
Range CMC2, 3 (±) Comments
Dimensional Inspection4
X Axis
Y Axis
Z Axis
Up to 35.43 in
Up to 59 in
Up to 39 in
(110 + 4.5L) µin
(150 + 6.6L) µin
(73 + 4.5L) µin
CMM
II. Dimensional Testing/Calibration
Parameter/Equipment
Range CMC2, 3 (±) Comments
Dimensional Calibration6
X Axis
Y Axis
Z Axis
Up to 35.43 in
Up to 59 in
Up to 39 in
(110 + 4.5L) µin
(150 + 6.6L) µin
(73 + 4.5L) µin
CMM
____________________________________________ | to 39 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6898.01) 7/15/2024 Page 2 of 2
1 This laboratory offers commercial inspection and calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of the CMC, L is the numerical value of the nominal length of the device measured in
inches.
4 This test is not equivalent to that of a calibration.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration | ||
| 3 | ISO/IEC 17025:20 17; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.