ANECO

19 RUE ROGER SALENGRO, 69740, GENAS, France

COFRAC|1-1863ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
5
Standards
17
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at ANECO?

Claim this profile to keep it accurate.

Register record

COFRACRefreshed
1-1863Active

Accredited standards

17

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN

EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
As written on the certificate · Line 3 (COFRAC 1-1863)

NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4

EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
As written on the certificate · Line 4 (COFRAC 1-1863)

XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132

EN 1948-4Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-1863)

NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4

EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
As written on the certificate · Line 2 (COFRAC 1-1863)

NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405

EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
As written on the certificate · Line 3 (COFRAC 1-1863)

NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4

EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
As written on the certificate · Line 3 (COFRAC 1-1863)

NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4

As written on the certificate · Line 5 (COFRAC 1-1863)

NF X 43-551; NF EN 13284-1; NF X 44-052

EN 14181Stationary source emissions - Quality assurance of automated measuring systems
As written on the certificate · Line 4 (COFRAC 1-1863)

XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132

EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
As written on the certificate · Line 3 (COFRAC 1-1863)

NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4

EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
As written on the certificate · Line 2 (COFRAC 1-1863)

NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405

EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
As written on the certificate · Line 2 (COFRAC 1-1863)

NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405

EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
As written on the certificate · Line 3 (COFRAC 1-1863)

NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4

EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
As written on the certificate · Line 2 (COFRAC 1-1863)

NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405

EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
As written on the certificate · Line 2 (COFRAC 1-1863)

NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405

EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
As written on the certificate · Line 2 (COFRAC 1-1863)

NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405

ISO

ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
As written on the certificate · Line 2 (COFRAC 1-1863)

NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405

ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
As written on the certificate · Line 3 (COFRAC 1-1863)

NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4

ISO 23210Stationary source emissions - Determination of PM10/PM2,5 mass concentration in flue gas - Measurement at low concentrations by use of impactors
As written on the certificate · Line 4 (COFRAC 1-1863)

XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132

Scope as published by COFRAC

5 lines
COFRAC

ISO/IEC 17025

Active

1-1863

The scope document we hold says it is valid until 2030-12-31.

View scope

Accredited scope, certificate 1-1863

LineDisciplineMethodMatrixRange
1environmentalNF EN ISO/IEC 17025AIR QUALITY-
2environmentalNF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405Flue gas-
3environmentalNF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4Flue gas-
4environmentalXP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132Flue gas-
5environmentalNF X 43-551; NF EN 13284-1; NF X 44-052Flue gas-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

19 RUE ROGER SALENGRO, GENAS, 69740, FR

45.72318, 4.98198

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.