ANECO
19 RUE ROGER SALENGRO, 69740, GENAS, France
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at ANECO?
Claim this profile to keep it accurate.
Register record
- COFRACRefreshed
- 1-1863Active
Accredited standards
17Our reading of the COFRAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132
EN 1948-4Name not checked yet
NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4
NF X 43-551; NF EN 13284-1; NF X 44-052
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405
EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405
ISO
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4
ISO 23210Stationary source emissions - Determination of PM10/PM2,5 mass concentration in flue gas - Measurement at low concentrations by use of impactors
XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132
Scope as published by COFRAC
5 lines
ISO/IEC 17025
Active1-1863
The scope document we hold says it is valid until 2030-12-31.
Accredited scope, certificate 1-1863
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | environmental | NF EN ISO/IEC 17025 | AIR QUALITY | - |
| 2 | environmental | NF EN 15259; NF X 43-551; NF EN ISO 16911-1; FD X 43-140; NF EN 14789; NF EN 14790; NF EN 12619; NF X 43-317; NF EN 14792; NF EN 15058; XP CEN/TS 17405 | Flue gas | - |
| 3 | environmental | NF EN 13284-1; NF X 44-052; NF EN 13211; NF EN 1911; NF CEN/TS 17340; NF EN 14791; NF EN ISO 21877; NF EN 14385; NF X 43-329; NF EN 1948-4 | Flue gas | - |
| 4 | environmental | XP X 43-136; NF EN 1948-1; NF EN ISO 23210; XP X43-554; NF EN 14181; XP X43-132 | Flue gas | - |
| 5 | environmental | NF X 43-551; NF EN 13284-1; NF X 44-052 | Flue gas | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in France
- MANUMESUREMEYZIEU · ~6 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
- CARSO - LABORATOIRE SANTÉ ENVIRONNEMENT HYGIÈNE DE LYON (CARSO - LSEHL)VENISSIEUX · ~8 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
- CME ENVIRONNEMENTSAINT-ETIENNE · ~58 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
- KALI'AIR SUDAIX-EN-PROVENCE · ~247 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
- EUROFINS ANALYSES DE L'AIRSAVERNE · ~379 kmCOFRACShares 2 accredited methods and materialsEN 13284-1Flue gas
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.