Registers refreshed 2026-11-08.See refresh dates
China

Radiolink Testing (Shenzhen) Co.,

Room 103, Building B Jinghang Industrial Park, Area 71, Xingdong Community, Xin'an Sub-district, Bao'an district, Shenzhen, People's Republic of China, Shenzhen, China

A2LA 7572.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
22
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 22 standard numbers and the 18 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series9
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national

National versions in the same scope

AS/NZS 61000.6.3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national

National versions in the same scope

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national

National versions in the same scope

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

EN4
EN 50364
EN 50385
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
FCC PART 15Radio Frequency Devices
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311, EN IEC 62311. Probably the same standard; not checked against the EN document.

IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

7572.01

The scope document we hold says it is valid until 2027-10-31.

View scope

Accredited scope, certificate 7572.01

LineMethodMatrixRange
1CFR 47, FCC Part 15 Subpart B; ANSI C63.4:2014; CFR 47, FCC Part 18; MP-5:1986; ICES-001; ICES- 003; ICES-005; CISPR 16-2-1; CISPR 16-2-3; CISPR 32; EN 55032; AS/NZS CISPR 32; CISPR 11; EN 55011; AS/NZS CISPR 11; CISPR 14-1; EN IEC 55014-1; AS/NZS CISPR 14.1; CISPR 15; EN IEC 55015; AS/NZS CISPR 15; IEC 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; IEC 61000-6-4; EN IEC 61000-6-4; AS 61000.6.4; IEC 61000-3-2; EN IEC 61000-3-2; IEC 61000-3-3; EN IEC 61000-3-3; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN IEC 61000-4-11; ISO/IEC 17025:2017--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7572.01) 10/03/2025 Page 2 of 4 Test: Test Method(s) 1: Product Immunity Standards CISPR 35; EN 55035; CISPR 14-2; EN IEC 55014-2; IEC 61547; EN IEC 61547; IEC 61000-6-1; EN IEC 61000-6-1; IEC 61000-6-2; EN IEC 61000-6-2; EN 50130-4 Product Specific Standards (Emissions and Immunity) IEC 60601-1-2; EN 60601-1-2; IEC 61326-1; EN IEC 61326-1; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-50; EN 301 489-52; EN 300 386 Radio Unlicensed Radio – FCC CFR 47, FCC Part 15 Subparts C/E/F (using ANSI C63.10:2020); CFR 47, FCC Part 15 Subpart E with DFS (using KDB 905462 D02) Licensed Radio – FCC CFR 47, FCC Parts 22, 24, 25, 27, 30, 73, 74, 90, 95, 96, 97, and 101 (using ANSI/TIA- 603-E and ANSI C63.26:2015); CFR 47, FCC Parts 20 and 90.219 (using ANSI C63.26:2015); TIA-102.CAAA-E Canada RSS-GEN; RSS-111; RSS-119; RSS-123; RSS-130; RSS-131; RSS-132; RSS-133; RSS-139; RSS-140; RSS-170; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; RSS-210 (< 40 GHz); RSS-211 (< 40 GHz); RSS-216 (< 40 GHz); RSS-220 (< 40 GHz); RSS-236; RSS-247 (with DFS); RSS-247 (without DFS); RSS-248; RSS-252; RSS-310 Australia AS/NZS 4268 European Union (EU) EN 300 220-1; EN 300 220-2; EN 300 330; EN 300 440; EN 300 328; EN 301 893; EN 303 687; EN 303 417; EN 303 413; EN 301 511; EN 301 908-1; EN 301 908-2; EN 301 908-3; EN 301 908-11; EN 301 908-13; EN 301 908-14; EN 301 908-15; EN 301 908-18; EN 301 908-24; EN 301 908-25; ETSI TS 138 521-3; 3GPP TS 38.521-3; ETSI TS 138 521-1; 3GPP TS 38.521-1; ETSI TS 138 106; 3GPP TS 38.106; ETSI TS 138 115-1; 3GPP TS 38.115-1; ETSI TS 138 115-2; 3GPP TS 38.115-2; ETSI TS 137 145-1; 3GPP TS 37.145-1; ETSI TS 137 145-2; 3GPP TS 37.145-2; ETSI TS 137 141; 3GPP TS 37.141; ETSI TS 138 141-1; 3GPP TS 38.141-1; ETSI TS 136 141; 3GPP TS 36.141; ETSI TS 125 141; 3GPP TS 25.141; ETSI TS 125 142; 3GPP TS 25.142; ETSI TS 138 104; 3GPP TS 38.104; ETSI TS 137 104; 3GPP TS 37.104; ETSI TS 136 104; 3GPP TS 36.104; ETSI TS 125 104; 3GPP TS 25.104; ETSI TS 125 105; 3GPP TS 25.105; ETSI TS 138 101-1; 3GPP TS 38.101-1; ETSI TS 138 101-3; 3GPP TS 38.101-1; ETSI TS 136 521-1; 3GPP TS 36.521-1; ETSI TS 134 121-1; 3GPP TS 34.121-1; ETSI TS 151.010-1; 3GPP TS 51.010-2; ETSI TS 136 521-4; 3GPP TS 36.521-4; ETSI TS 138 124; 3GPP TS 38.124
3IEC 62311; EN IEC 62311; IEC 62479; EN 62479; EN 50385; EN 50364; EN 50663; EN 50665; KDB 447498 D01; AS/NZS 2772.2; RPS S-1; RPS S-1 Advisory Note; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E-to 40000 MHz
4ANSI/TIA-603-E; ANSI C63.26:2015-to 40000 MHz

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.