INSCO, Instrumentation Services
San Juan, United States
Visit website- Accredited standards
- 3
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM E898
ISO 8655-6Piston-operated volumetric apparatus - Part 6: Gravimetric reference measurement procedure for the determination of volume
USP 41
ASTM E898-20; NIST HB 44; Euramet cg-18; USP 41; ISO 8655-6
ISO 8655-6
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active5247.01
The scope document we hold says it is valid until 2027-12-31.
Accredited scope, certificate 5247.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5247.01) 1/23/2026 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
INSCO, INSTRUMENTATION SERVICES INC.
279 Pinero Ave,
Rio Piedras, Puerto Rico 00927
Denio Hernandez Phone: 787 765 5564
CALIBRATION
Valid To: December 31, 2027 Certificate Number: 5247.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 4 (±) Comments
DC Voltage – Generate3
(0 to 30) mV
(0 to 60) mV
(0 to 300) mV
(0 to 5) V
(5 to 7.5) V
(7 to 10) V
21 µV
58 µV
0.58 µV
21 µV
70 µV
100 µV
Krohn-Hite 523 calibrator
Krohn-Hite 523 calibrator
DC Voltage – Measure3
(0 to 10) V
10 mV
Beamex MC5
DC Current – Generate3
4 mA
12 mA
20 mA
1.0 µA
10 µA
4.0 µA
Krohn-Hite 523 calibrator
DC Current – Measure3
4 mA
12 mA
20 mA
0.22 mA
0.22 mA
0.22 mA
Beamex MC5
Resistance – Measure3
Up to 100 Ω
5.8 mΩ
Standard resistor | ||
| 2 | ASTM E898-20; NIST HB 44; Euramet cg-18; USP 41; ISO 8655-6 | - | See scope document |
| 3 | ISO 8655-6 | - | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5247.01) 1/23/2026 Page 4 of 5
_____________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
Parameter/Equipment
Range CMC2 (±) Comments
Thermocouples – Probes3 (cont.)
Type K (cont)
Type N
Type S
Type T
(0 to 50) °C
(50 to 100) °C
(100 to 200) °C
(200 to 600) °C
(600 to 1100) °C
(-195 to -95) °C
(-95 to -40) °C
(-40 to -20) °C
(-20 to 0) °C
(0 to 50) °C
(50 to 100) °C
(100 to 200) °C
(200 to 750) °C
(50 to 1100) °C
(-195 to -95) °C
(-95 to -40) °C
(-40 to -20) °C
(-20 to 0) °C
(0 to 50) °C
(50 to 100) °C
(100 to 200) °C
(200 to 250) °C
(250 to 400) °C
0.58 °C
0.58 °C
0.58 °C
0.71 °C
1.3 °C
0.66 °C
0.49 °C
0.49 °C
0.49 °C
0.49 °C
0.49 °C
0.49 °C
1.2 °C
1.4 °C
0.50 °C
0.45 °C
0.47 °C
0.41 °C
0.41 °C
0.41 °C
0.41 °C
0.41 °C
0.41 °C
Beamex MC5 | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5247.01) 1/23/2026 Page 5 of 5
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 6 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.