Albarubens
Via Consorziale Saronnino 70/22, Origgio, 21040, Italy, Origgio, Italy
Visit website- Accredited standards
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 15 standard numbers and the 11 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series7
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-21
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-60
ISO3
ISO 9227Corrosion tests in artificial atmospheres - Salt spray testsSome clauses
Limits written next to it
ISO 9227:2022 (Only NSS test)
ISO 16852Flame arresters - Performance requirements, test methods and limits for use
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
ISO 80079 series3
ISO 80079-36Explosive atmospheres - Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements
ISO 80079-37Explosive atmospheres - Part 37: Non-electrical equipment for explosive atmospheres - Non-electrical type of protection constructional safety ''c'', control of ignition sources ''b'', liquid immersion ''k''
ISO/IEC 80079-49Explosive atmospheres - Part 49: Flame arresters - Performance requirements, test methods and limits for use
Other standards2
IEC 60079-0Exclusion
Limits written next to it
EN IEC 60079-0:2018/AC:2020-02 (Except
IEC 60079-0:2017 + COR1:2020 (Except 26.10
IEC 60079-29-1
ISO/IEC 17025:2017 ALBARUBENS SRL Via Consorziale Saronnino 70/22 21040; IEC 17025; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-11
ISO 9227:2022; IEC 60068-2-60; IEC 60079-29-1; IEC 60068-2-1; IEC 60068-2-2
ISO 9227:2022; ISO 20653:2023 Explosive Atmosphere Explosive atmospheres - Part 0: Equipment - General requirements1 IEC 60079-0:2017; IEC 60068-2-21; IEC 60068-2-30; IEC 60068-2-52
ISO 80079-36:2016; ISO 80079-36:2016/Cor 1:2019; ISO 80079-37:2016; ISO 16852:2017; ISO IEC 80079-49:2024
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active4359.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 4359.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 ALBARUBENS SRL Via Consorziale Saronnino 70/22 21040; IEC 17025; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-11 | - | -65 to 750 °C |
| 2 | ISO 9227:2022; ISO 20653:2023 Explosive Atmosphere Explosive atmospheres - Part 0: Equipment - General requirements1 IEC 60079-0:2017; IEC 60068-2-21; IEC 60068-2-30; IEC 60068-2-52 | water | - |
| 3 | ISO 80079-36:2016; ISO 80079-36:2016/Cor 1:2019; ISO 80079-37:2016; ISO 16852:2017; ISO IEC 80079-49:2024 | air | - |
| 4 | ISO 9227:2022; IEC 60068-2-60; IEC 60079-29-1; IEC 60068-2-1; IEC 60068-2-2 | - | - |
| 5 | Calibration procedure of gas sensors in % v/v; Calibration procedure of gas sensors in ppm vol; Field calibration procedure for gas sensors | Volumetric Gas Mixture Concentration | See scope document |
| 6 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.