FMA FELB FORGING GROUP
via delle Industrie 17, 20044, Arese, Italy
Visit website- Accredited standards
- 17
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 17 standard numbers and the 17 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM11
ASTM A262Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
ASTM E10Standard Test Method for Brinell Hardness of Metallic MaterialsExclusion
Limits written next to it
ASTM E10-23 - escluso/except par
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic MaterialsExclusion
Limits written next to it
ASTM E18-24 - escluso/except par
ASTM E23Standard Test Methods for Notched Bar Impact Testing of Metallic Materials
ASTM E112Standard Test Methods for Determining Average Grain SizeSome clauses
Limits written next to it
ASTM E112-24 - solo/only par
ASTM E407Standard Practice for Microetching Metals and Alloys
ASTM E562Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count
ASTM G48Standard Test Methods for Pitting and Crevice Corrosion Resistance of Stainless Steels and Related Alloys by Use of Ferric Chloride Solution
ISO6
ISO 148-1Metallic materials - Charpy pendulum impact test - Part 1: Test method
ISO 643Steels - Micrographic determination of the apparent grain size
Limits written next to it
UNI EN ISO 643:2024 - solo/only Solo
ISO 3651-2Determination of resistance to intergranular corrosion of stainless steels - Part 2: Ferritic,austenitic and ferritic-austenitic (duplex) stainless steels - Corrosion test in media containing sulfuric acid
ISO 6506-1Metallic materials - Brinell hardness test - Part 1: Test method
ISO 6508-1Metallic materials - Rockwell hardness test - Part 1: Test method
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
UNI EN ISO 3651-2:2000/EC1:2002; ASTM A262-15(2021); ASTM G48-11(2020)e1; UNI EN ISO 643:2024; ASTM E562-19e1; UNI 3137:1965; ASTM E112-24; UNI EN ISO 6506-1:2015; ASTM E10-23; ASTM A370-24a; ASTM E18-24; UNI EN ISO 6508-1:2024; ASTM E3-11(2017) + ASTM E407-23; UNI EN ISO 148-1:2016; ASTM E23-25; ASTM E8/E8M-24; UNI EN ISO 6892-1:2020
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active01294
Accredited scope, certificate 01294
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI EN ISO 3651-2:2000/EC1:2002; ASTM A262-15(2021); ASTM G48-11(2020)e1; UNI EN ISO 643:2024; ASTM E562-19e1; UNI 3137:1965; ASTM E112-24; UNI EN ISO 6506-1:2015; ASTM E10-23; ASTM A370-24a; ASTM E18-24; UNI EN ISO 6508-1:2024; ASTM E3-11(2017) + ASTM E407-23; UNI EN ISO 148-1:2016; ASTM E23-25; ASTM E8/E8M-24; UNI EN ISO 6892-1:2020 | Metal | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. FMA FELB FORGING GROUP SPA
via delle Industrie 17
20044 Arese MI
Legenda/Note
Allegato al certificato di accreditamento n. 01294 rev. 5 del 25/06/2025
UNI CEI EN ISO/IEC 17025:2018
Revisione: 16
Sede A
Data: 15/07/2025
pag. 2 di 2
Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not
provided for by the method but acceptable
Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title,
see ACCREDIA General Regulation RG-02.
Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento
rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the
accreditation certificate issued to the laboratory.
L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui
risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions
and interpretations based on the results of the specific marked tests.
L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that
a suspension of accreditation is active for the specific activity shown next to it. | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- Laboratorio T.O.S.I.Legnano · ~13 kmACCREDIAShares 2 accredited methods and materialsASTM E10-23Metal
- IRCM - ISTITUTO RICERCA CONTROLLO MATERIALISolbiate Arno · ~28 kmACCREDIAShares 2 accredited methods and materialsASTM E10-23Metal
- SIGMATRE LAB S.R.L.Garbagnate Monastero · ~30 kmACCREDIAShares 2 accredited methods and materialsASTM E10-23Metal
- I-TT LAB SRLSumirago · ~31 kmACCREDIAShares 2 accredited methods and materialsASTM E10-23Metal
- S.M.T. S.r.l.Pozzo d'Adda · ~33 kmACCREDIAShares 2 accredited methods and materialsASTM E10-23Metal
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.