Registers refreshed 2026-11-08.See refresh dates
France

REMINEX - CENTRE DE RECHERCHE

Tel. : 00 212529 801940, Fax : 212524 437160, France

COFRAC 1-0789ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
25
COFRAC certificate
1
Sites in our directory
2
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 25 standard numbers and the 16 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO12
ISO 5814Water quality - Determination of dissolved oxygen - Electrochemical probe method
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 8467Water quality - Determination of permanganate index
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9963-1Water quality - Determination of alkalinity - Part 1: Determination of total and composite alkalinity
ISO 10523Water quality - Determination of pH
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 12846Water quality - Determination of mercury - Method using atomic absorption spectrometry (AAS) with and without enrichment
ISO 15587-2Water quality - Digestion for the determination of selected elements in water - Part 2: Nitric acid digestion
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
NF8
NF T90-004
NF T90-029
NF T90-040
NF T90-043
NF T90-107
NF T 90-003
NF T 90-015-2
NF T 90-101
EN4
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
Other standards1
T 90-015-1

Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-06.

Scope as published by COFRAC

7 lines
COFRAC

ISO/IEC 17025

Active

1-0789

The scope document we hold says it is valid until 2026-12-31.

View scope

Accredited scope, certificate 1-0789

LineMethodMatrixRange
1-Metal
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Convention N° 436 LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 1/9 Section Laboratoires ATTESTATION D’ACCREDITATION ACCREDITATION CERTIFICATE N° 1-0789 rév. 16 Le Comité Français d'Accréditation (Cofrac) atteste que : The French Committee for Accreditation (Cofrac) certifies that : REMINEX Satisfait aux exigences de la norme NF EN ISO/IEC 17025 : 2017 Fulfils the requirements of the standard et aux règles d’application du Cofrac pour les activités d’analyses/essais/étalonnages en : and Cofrac rules of application for the activities of testing/calibration in : MATERIAUX / MATERIAUX METALLIQUES MATERIALS / METALLIC MATERIALS ENVIRONNEMENT / QUALITE DE L'EAU ENVIRONMENT / WATER QUALITY EQUIPEMENTS INDUSTRIELS ET PRODUITS D'INGENIERIE / PRODUITS DE PROCEDES INDUSTRIELS INDUSTRIAL EQUIPMENTS AND ENGINEERING PRODUCTS / INDUSTRIAL PROCESSES PRODUCTS réalisées par / performed by : REMINEX - CENTRE DE RECHERCHE REMINEX - Centre de Recherche - BP 469 MARRAKECH MEDINA MAROC et précisément décrites dans l’annexe technique jointe, à l’exclusion des activités réalisées dans les pays listés dans le document GEN INF 16, dont la version en vigueur est disponible sur le site internet du Cofrac (www.cofrac.fr). and precisely described in the attached technical appendix, excluding activities performed in the countries listed in the document GEN INF 16, the current version of which is available on our website (www.cofrac.fr). L’accréditation suivant la norme internationale homologuée NF EN ISO/IEC 17025 est la preuve de la compétence technique du laboratoire dans un domaine d’activités clairement défini et du bon fonctionnement dans ce laboratoire d’un système de management adapté (cf. communiqué conjoint ISO- ILAC-IAF en vigueur disponible sur le site internet du Cofrac www.cofrac.fr) Accreditation in accordance with the recognised international standard NF EN ISO/IEC 17025 demonstrates the technical competence of the laboratory for a defined scope and the proper operation in this laboratory of an appropriate management system (see current Joint ISO -ILAC-IAF Communiqué available on Cofrac web site www.cofrac.fr) . Le Cofrac est signataire de l’accord multilatéral d’EA pour l’accréditation , pour les activités objets de la présente attestation. Cofrac is signatory of the European co -operation for Accreditation (EA) Multilateral Agreement for accreditation for the activities covered by this certificate.
-
2-Metal
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 4/9 Unité technique : SERVICE ANALYSES L’accréditation porte sur : MATERIAUX / MATERIAUX METALLIQUES / Analyses physico-chimiques Objet Caractéristique mesurée ou recherchée Principe de la méthode Référence de la méthode Alliages de Cobalt Eléments : Al, P, Ti, Cr, Zr, Nb, B, V, S, Mo, W, Ta Spectrométrie d'émission à plasma induit couplé à un détecteur optique (ICP-OES) après mise en solution de l'échantillon Méthode interne * : CR/AN/MO/71.00 Eléments : Fe, Cu, Mn, Ni, Zn, Pb, Cd Spectrométrie d'absorption atomique après mise en solution de l'échantillon Méthode interne * : CR/AN/MO/10.00 Elément : Co Potentiométrie après mise en solution de l'échantillon Méthode interne * : CR/AN/MO/16.00 Eléments : C, S Combustion et absorption infrarouge sur échantillon solide Méthode interne * : CR/AN/MO/14.00 Alliages de Cuivre Eléments : Si, Al, Sn, Sb, Cr, Se, Te, S, P Spectrométrie d'émission à plasma induit couplé à un détecteur optique (ICP-OES) après mise en solution de l'échantillon Méthode interne * : CR/AN/MO/13.00 Eléments : Fe, Cu, Mn, Ni, Zn, Pb, Ag, Bi, As, Co Spectrométrie d'absorption atomique après mise en solution de l'échantillon Méthode interne * : CR/AN/MO/75.00 Eléments : Cu Méthode volumétrique après mise en solution de l'échantillon Méthode interne * : CR/AN/MO/15.00 Eléments : C Combustion et absorption infrarouge sur échantillon solide Méthode interne * : CR/AN/MO/14.00 *Portée fixe : Le laboratoire est reconnu compétent pour pratiquer les méthodes décrites en respectant strictement les méthodes mentionnées dans la portée d’accréditation. Les modifications techniques du mode opératoire ne sont pas autorisées.
-
3NF EN 27888; NF EN ISO 10523; NF T 90-029; NF EN ISO 5814; NF EN ISO 7027-1; NF EN ISO 9963-1; NF T 90-003; NF EN ISO 8467; CR/AN/MO/44.00; NF ISO 9297; NF EN 26777; NF T 90-040; NF EN ISO 6878; NF T 90-004; NF T 90-015-1; NF T 90-015-2; NF T 90-043; NF EN 25663; NF EN ISO 5815-1; NF T 90-101; NF EN 872; NF T 90-107; CR-AN-MO-115.00Surface water-
4NF EN ISO 12846; NF EN ISO 15587-2; NF EN ISO 11885; NF EN ISO 17294-2Surface water-
5CR/AN/MO/95.00; CR/AN/MO/94.00; CR/AN/MO/103; CR/AN/MO/92.00; CR/AN/MO/102.00; CR/AN/MO/70.00; CR-AN-MO-111.00Soil-
6CR-AN-MO-114.00; CR-AN-MO-107.00; CR/AN/MO/128.00Soil-
7CR/AN/MO/65.00; CR/AN/MO/131.00; CR/AN/MO/132.00; CR/AN/MO/133.00; CR/AN/MO/66.00; CR/AN/MO/101.00Soil-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

1 other site in this organization

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.