Visional Technology LLC (Limited Liability Corporation)

362 Cesar Gonzalez Street, San Juan, 00918-2113, Puerto Rico, San Juan, United States

Visit website
A2LA 4111.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 4111.01 · 5 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4111.01) Revised 5/9/2025 Page 1 of 4 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 VISIONAL TECHNOLOGY LLC (LIMITED LIABILITY CORPORATION) 362 Cesar Gonzales Street San Juan, Puerto Rico 00918 Joyce Rotger Phone: 787 525 0552 CALIBRATION Valid To: November 30, 2026 Certificate Number: 4111.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6, 7: I. Dimensional Testing/Calibration Parameter/Equipment Range CMC2, 4 (±) Comments Vision Measurement System3 – Length Accuracy Z-Axis Linear Error (1D Tactile) Euv – Length Error of the Imaging Probe Probing Error (PF2D) Probing Error of the Imaging Probe (PFV2D) Up to 758 mm Up to 177 mm Up to 150 mm Up to 3.5 mm 14 mm Up to 3.5 mm 14 mm (0.52 + 0.00077L) μm (0.38 + 0.0063L) µm (1.0 + 0.0021L) μm 0.44 μm 1 µm 0.57 μm 1 µm Glass line scale Gage blocks Glass line scale Circle chart Circle chart
to 758 mm
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4111.01) Revised 5/9/2025 Page 2 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Coordinate Measuring Machines (CMM)3 Length Accuracy Probe Performance Scanning Performance Up to 1000 mm Up to 25 mm Up to 25 mm (0.14 + 0.0002L) μm 0.15 μm 0.12 μm Step gage Sphere Sphere Optical Comparator3 – Length Accuracy (Vertical) Length Accuracy (Horizontal) Chart Rotation (Angles) Up to 192 mm Up to 8 in Up to 606 mm Up to 24 in Up to 360° (1.7 + 0.003L) μm (66 + 3L) µin (0.65 + 0.0019L) μm (26 + 1.9L) μin 1.2 Arcminutes Glass scale Glass scale Glass reticle Optical - Scales, Reticles, Grid/Dot Array Diameters Angles Distances Up to 3.5 mm Up to 400 mm Up to 360° Up to 758 mm 0.41 μm (2.1 + 0.0035D) μm 1.0 Arcminutes (0.52 + 0.00142L) µm Vision system by comparison to calibrated standards Vision system Vision system by comparison to calibrated standards Steel Rules Up to 640 mm (3.9 + 0.0025L) μm Vision system Length Standards Up to 758 mm (0.10 + 0.00023L) μm CMM by comparison to laboratory primary length standards Micrometers7 Up to 1 in (1 to 2) in 4 µin (15 + 1L) µin Gage blocks Calipers7 Up to 24 in. (144 + 0.2L) µin Gage blocks
to 1000 mm
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4111.01) Revised 5/9/2025 Page 3 of 4 II. Dimensional Testing Parameter/Equipment Range CMC2, 4 (±) Comments Length Measurements5 Up to 640 mm (2.0 + 0.0034L) μm CMM, vision system Diameter5 Up to 3.5 mm Up to 400 mm 0.41 μm (2.1 + 0.0035D) μm. CMM, vision system by comparison to calibrated standards CMM, vision system Angle5 Up to 360° (0.53 + 0.0015A) Arcminutes CMM, vision system ____________________________________________ 1 This laboratory offers commercial calibration service, field calibration service, and dimensional testing. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This laboratory performs field calibration activities for these parameters. Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, ( e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in millimeters (metric units) or inches (imperial units); D is the numerical value of the nominal diameter of the device measured in millimeters (metric units) or inches (imperial units); and A is the nominal numerical value of an angle measured in decimal degrees. 5 This test is not equivalent to that of a calibration. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
to 640 mm
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4111.01) Revised 5/9/2025 Page 4 of 4 7 Repeatability of the Unit Under Test has not been utilized in the calculation of the CMC value for this measurement parameter.
5ISO/IEC 17025:20 17; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

362 Cesar Gonzalez Street, San Juan, 00918-2113, Puerto Rico, San Juan, US

18.46530, -66.11667

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.