FindTestingLabs
Registers refreshed 2026-11-06.See refresh dates
United States

Architectural Testing, Inc. (An Intertek Company)

Edgewood, NY, United States

A2LA 7250.15ISO/IEC 17025Register refreshed 2026-11-06
One of 5 sites of this organization in our directory. View the organizationPart of the Intertek group: 85 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
13
A2LA certificate
1
Sites in our directory
5
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 13 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM13
ASTM E283
ASTM E330
ASTM E331
ASTM E547
ASTM E783
ASTM E987
ASTM E1105
ASTM E1186
ASTM E1886
ASTM E1996
ASTM E2068
ASTM F588
ASTM F842

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

7250.15

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 7250.15

LineMethodMatrixRange
1ISO/IEC 17025:2017; ASTM: E329; E699; AAMA 450; AAMA 501.1; AAMA 501.4; AAMA 501.5; AAMA 501.7; AAMA 501.9; AAMA 910; AAMA 920; AAMA 1102.7; AAMA 1302; AAMA 1303; AAMA 1304Materials-
2AAMA 1701.2; AAMA 1702.2; AAMA/NPEA/NSA 2100; ASTM E2068; ASTM F588; ASTM F842; AAMA 502; AAMA 503; AAMA 506; AAMA 511; AAMA 925; AAMA 1002.10; AAMA 1102.7; AAMA 2502; ANSI Standard Z97.1; ANSI/AAMA 101/ CSA 101/440/ I.S.2/NAFS; ANSI/FM Approvals 2510; ASTM E283; ASTM E330; ASTM E331; ASTM E547; ASTM E783; ASTM E987--
3ASTM E1105; ASTM E1186; ASTM E1886; ASTM E1996; ASTM F588; ASTM F842; FBC TAS 201; FBC TAS 202; FBC TAS 203; AAMA 501.2exterior windows; skylights; doors; curtain walls; building envelopes; air barrier systems; storefronts; sloped glazing systems-
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited ARCHITECTURAL TESTING, INC. (AN INTERTEK COMPANY) Farmingdale, NY for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 3rd day of December 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7250.15 Valid to July 31, 2027 Revised February 9, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Edgewood, NY, US

42.14037, -74.21237

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.