United States

Bekaert Corporation

510 Collins Blvd, 44667, Orrville, OH, United States

Visit website
A2LA 1417.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 5 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM A90
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A938
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E112Standard Test Methods for Determining Average Grain Size

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

1417.01

The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 1417.01

LineMethodMatrixRange
1ASTM A370; ASTM A938; ASTM A90; ASTM E3; ASTM E112Metal-
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1417.01) 04/15/2024 Page 2 of 2 I. Dimensional Testing1 Parameter/Equipment Range CMC2 (±) Comments Linear (1D)3 – Up to 1 in (1 to 2) in Up to 6 in 0.000 18 in 0.000 278 in 0.0012 in Micrometer Micrometer Caliper _______________________________ 1 This laboratory does not offer commercial dimensional testing service 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or n early ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This test is not equivalent to that of a calibration.
to 6 in
3ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

510 Collins Blvd, Orrville, OH, 44667, US