Bekaert Corporation
510 Collins Blvd, 44667, Orrville, OH, United States
Visit website- Accredited standards
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 5 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM A90
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A938
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E112Standard Test Methods for Determining Average Grain Size
ASTM A370; ASTM A938; ASTM A90; ASTM E3; ASTM E112
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active1417.01
The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.
Accredited scope, certificate 1417.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM A370; ASTM A938; ASTM A90; ASTM E3; ASTM E112 | Metal | - |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1417.01) 04/15/2024 Page 2 of 2
I. Dimensional Testing1
Parameter/Equipment
Range
CMC2 (±)
Comments
Linear (1D)3 –
Up to 1 in
(1 to 2) in
Up to 6 in
0.000 18 in
0.000 278 in
0.0012 in
Micrometer
Micrometer
Caliper
_______________________________
1 This laboratory does not offer commercial dimensional testing service
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or n early ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 This test is not equivalent to that of a calibration. | to 6 in |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- ICC Evaluation ServiceElkhart, IN · ~367 kmA2LAShares 2 accredited methods and materialsASTM A370Metal
- Advanced Plastic and Material TestingIthaca, NY · ~476 kmA2LAShares 2 accredited methods and materialsASTM A370Metal
- Charter Steel Saukville Rolling & Processing Div.Saukville, WI · ~582 kmA2LAShares 2 accredited methods and materialsASTM A370Metal
- Siemens Energy, Inc Charlotte Materials and Joining CenterCharlotte, NC · ~632 kmA2LAShares 2 accredited methods and materialsASTM A370Metal
- Accurate Weldment TestingNew Iberia, LA · ~1,511 kmA2LAShares 2 accredited methods and materialsASTM A370Metal
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.