Registers refreshed 2026-11-08.See refresh dates
Germany

Umicore AG & Co. KG Analytical Competence Center Hanau

Rodenbacher Chaussee 4, 63457, Hanau, Germany

Visit website
DAKKS D-PL-14011-01-00DAKKS D-PL-14011-01-01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
1
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ISO 9277Determination of the specific surface area of solids by gas adsorption - BET method

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

8 lines
DAKKS

ISO/IEC 17025

Active

D-PL-14011-01-00

View scope

Accredited scope, certificate D-PL-14011-01-00

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001Legierungen, Katalysatoren, Metallorganischen Produkten und Edelmetallprodukten-
2-Metal
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-14011-01-00 Gültig ab: 02.05.2023 Ausstellungsdatum: 02.05.2023 Seite 2 von 4 1 Physikalisch-chemische und chemische Untersuchung en von Legierungen, Katalysatoren und Edelmetallprodukten mittels gravimetrischer Ve rfahren AV CRD -ACC -HU 1056 D -6.0 2020-03-24 Gravimetrische Platin Bestimmung in Platinprodukten AV CRD -ACC -HU 1024 D -5.0 2020-03-24 Gravimetrische Palladium Bestimmung in Palladiumprodukten AV CRD -ACC -HU 1022 D -5.0 2020-03-24 Gravimetrische Rhodium Bestimmung in Rhodiumprodukten AV CRD -ACC -HU 1118 D -6.0 2021-04-28 Thermogravimetrische Bestimmung des Glühverlustes (Loss of Ignition ) in Katalysatoren und Katalysatorvorprodukten mit Leco TGA 701 und Eltra Thermostep 2 Physikalisch-chemische und chemische Untersuchung en von Legierungen, Katalysatoren und Edelmetallprodukten mittels Atomemissionsspektrometrie mit induktiv gekoppeltem Plasma (ICP-OES) und ICP-MS AV CRD -ACC -HU 1082 D -9.0 2021-04-28 Bestimmung der Edelmetalle in Katalysatoren mittels Sn/Te -Fällung und ICP-OES AV CRD -ACC -HU 1013 D -6.0 2020-03-04 Bestimmung des Platins in Platinprodukten mittels ICP -OES AV CRD -ACC -HU 1050 D -6.0 2020-02-26 Bestimmung des Palladiums in Palladiumprodukten mittels ICP -OES AV CRD -ACC -HU 1049 D -5.0 2020-03-04 Bestimmung des Rhodium in Rhodiumprodukten mittels ICP -OES AV CRD -ACC -HU 2029 D-2.0 2020-03-24 Direkte Bestimmung der Edelmetalle in Edelmetall-organischen Produkten mittels ICP-OES AV CRD -ACC -HU 2030 D-4.0 2020-03-18 Bestimmung der Edelmetalle in Edelmetall-organischen Produkten nach Schwefelsäureaufschluss mittels ICP-OES AV CRD -ACC -HU 1238 GER-2.0 2021-04-28 Bestimmung von Pd , Pt, und Rh in Katalysatoren und deren Vorprodukten mittels Sn/Te Fällung (Variante f) AV CRD -ACC -HU 1281 GER-2.0 2022-09-06 Bestimmung von Pt oder Pt/Co in Brennstoffzellenkatalysatoren mittels ICP-OES
-
3-Metal
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-14011-01-00 Gültig ab: 02.05.2023 Ausstellungsdatum: 02.05.2023 Seite 3 von 4 AV CRD -ACC -HU 1309 GER-1.0 2021-04-28 Bestimmung des Ir - und N b-Gehaltes in Brennstoffzellenkatalysatoren mittels ICP-OES AV CRD -ACC -HU 2160 GER-1.0 2020-03-24 Analyse der metallischen Verunreinigungen in Co -organischen Verbindungen mittels ICP-OES und ICP-MS AV CRD -ACC -HU 1287 GER-1.0 2022-09-05 Bestimmung von Edelmetalllegierungen (PtPdRh) der BU JIM mittels ICP-OES 3 Physikalisch-chemische und chemische Untersuchung en von Legierungen, Katalysatoren und Edelmetallprodukten mittels Röntgenfluoreszenzanalyse (RFA) AV CRD -ACC -HU 3009 GER-2.0 2021-05-06 Quantitative Bestimmung von Edelmetallen und Matrixelementen in Autoabgaskatalysatoren und deren Zwischenprodukten mittels Röntgenfluoreszenzanalyse mit Pulverpresslingen AV CRD -ACC -HU 3010 GER-2.0 2022-08-26 Quantitative Bestimmung von Matrixelementen in Autoabgas - katalysatoren und deren Zwischenprodukte mittels Röntgen- fluoreszenzanalyse mit Schmelzlingen AV CRD -ACC -HU 1328 GER-1.0 2022-08-29 Analyse von Autoabgaskatalysatorendprodukten und deren Intermediären (oder vergleichbar) mittels Glassbead und energiedispersiven Röntgenfluoreszenzanalyse 4 Chromatographische Untersuchung von Metallorganischen Produkten mittels Gaschromatographie (GC) AV CRD -ACC -HU 5022 GER-2.0 2021-05-06 Bestimmung der Reinheit von organischen Cobaltverbindungen mittels Gaschromatographie ( GC )
-
4ISO 9277 2022-11; en ISO 9277 2022-11Solids-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS

ISO/IEC 17025

Active

D-PL-14011-01-01

View scope

Accredited scope, certificate D-PL-14011-01-01

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018alloys; catalysts; organometallic products; precious metal products-
2-alloys; catalyst; precious metal products; platinum products; palladium products; rhodium products; catalyst precursors; organo metallic products; automotive catalysts; fuell cells catalysts
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Annex to the Accreditation Certificate D-PL-14011-01-01 Valid from : 13.03.20 26 Date of issue : 13.03.2026 page 2 of 4 This document is a translation. The definitive version is the original German annex to the accreditation certificate. 1 Physico-chemical and chemical analysis of alloys, catalyst and precious metal products using gravimetric methods AV CRD -ACC -HU 1056 D -7.0 2025-04-23 Gravimetric determination of Platinum in platinum products AV CRD -ACC -HU 1024 D -6.0 2025-04-14 Gravimetric determination of Palladium in palladium products AV CRD -ACC -HU 1022 D -6.0 2025-04-14 Gravimetric determination of Rhodium in rhodium products AV CRD -ACC -HU 1118 D -7.0 2025-04-14 Thermo gravimetric determination of the loss of ignition in catalyst and catalyst precursors with Leco TGA 701 or Eltra Thermostep 2 Physico-chemical and chemical analysis of alloys, catalysts, and precious metal products with inductively coupled plasma atomic emission spectroscopy with (ICP-OES) and AV CRD -ACC -HU 1082 D -10.0 2025-06-13 Determination of precious metals in catalysts with Sn/Te - precipitation an ICP-OES AV CRD -ACC -HU 1013 D -7.0 2025-04-14 Determination of Platinum in platinum products with ICP -OES AV CRD -ACC -HU 1050 D -7.0 2025-04-14 Determination of Palladium in palladium products with ICP -OES AV CRD -ACC -HU 1049 D -6.0 2025-04-14 Determination of Rhodium in rhodium products with ICP -OES AV CRD -ACC -HU 2029 -3.0 2025-06-13 Direct determination of precious metals in organo metallic products with ICP-OES AV CRD -ACC -HU 2030 D -5.0 2025-07-07 Determination of precious metals in organo metallic products after sulfuric acid digestion with ICP-OES AV CRD -ACC -HU 1238 GER -3.0 2025-05-12 Determination of Pd, Pt and Rh in automotive catalysts and their intermediates after Sn / Te precipitation (variant f) AV CRD -ACC -HU 1281 GER -4.0 2025-04-30 Determination of Pt or Pt/Co in fuell cells catalysts with ICP -OES
-
3ISO 9277solids; catalysts; precious metal products; automotive catalysts; fuel cells catalysts; precious metal anorganic solutions - solids and excipients-
4DIN; EN; IEC; ISO--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Rodenbacher Chaussee 4, Hanau, 63457, DE

50.11958, 8.96512

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.