Miejskie Wodociągi i Kanalizacja w Bydgoszczy - Spółka z ograniczoną odpowiedzialnością
ul. Koronowska 96, 85-405, Bydgoszcz, Poland
No active accreditation in the register.
Scope as published by PCA
8 lines
ISO/IEC 17025
SuspendedAB 396
The scope document we hold says it was valid until 2026-08-06. That date has passed, so our copy may be out of date. We downloaded it from the PCA register on 2026-03-13. Check the PCA register for the current scope.
Accredited scope, certificate AB 396
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Drinking waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 396
Scope of accreditation No. AB 396
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 396
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 23 z/of 16.05.2025
p.o. KIEROWNIKA DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 396 z dnia 29.04.2019 r.
Cykl akredytacji od 21.07.2022 r. do 06.08.2026 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 396 of 29.04.2019
Accreditation cycle from 21.07.2022 to 06.08.2026
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 23, 16.05.2025 1/9
Nazwa i adres / Name and address
MIEJSKIE WODOCIĄGI I KANALIZACJA W BYDGOSZCZY
- Spółka z ograniczoną odpowiedzialnością
ul. Toruńska 103
85-817 Bydgoszcz
CENTRALNE LABORATORIUM BADANIA WODY I ŚCIEKÓW
ul. Koronowska 96
85-405 Bydgoszcz
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/29/P; C/30/P
- C/28
- K28/P; K/29/P
- N/29/P; N/30/P
- N/28
- Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków / Chemical tests and
sampling of drinking water, sewage
- Badania chemiczne wody / Chemical tests of water
- Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi / Microbiological
tests and sampling of water, drinking water
- Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków / Tests of
physical properties and sampling of drinking water, sewage
- Badania właściwości fizycznych wody / Tests of physical properties of water
Wersja strony: A
AB 396 | - |
| 2 | PN-ISO 5667-5:2017-10; PN-77/C-04584; PN-EN 27888:1999; PN-82/C-04576.08; PN-EN 26777:1999; PN-ISO 9297:1994; PN-92/C-04590.02; PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010; PN-ISO 6059:1999; PN-EN ISO 7980:2002; PN-ISO 9964-1:1994+Ap1:2009; PN-ISO 9964-2:1994 | Drinking water | See scope document |
| 3 | PN-ISO 7150-1:2002; PN-EN ISO 17852:2009; PN-ISO 9280:2002; PN-EN ISO 17294-2:2024-04; PN-EN ISO 7887:2012 p.6+Ap1:2015; PN-EN ISO 10523:2012; PN-EN ISO 7027-1:2016-09; PN-ISO 6332:2001+Ap1:2016; PN-EN 1484:1999; PN-EN ISO 8467:2001 | Drinking water | See scope document |
| 4 | PN-ISO 8288:2002; PN-EN ISO 9377-2:2003 | Drinking water | See scope document |
| 5 | PN-EN 1484:1999; PN-ISO 8288:2002; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO 10301:2002; PN-EN ISO 17294-2:2024-04 | Waste water | See scope document |
| 6 | PN-ISO 5667-10:2021-11; PN-77/C-04584; PN-EN 872:2007+Ap1:2007; PN-EN ISO 10523:2012; PN-EN 27888:1999; PN-82/C-04576/08; PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010; PN-EN 26777:1999; PN-ISO 9297:1994; PN-74/C-04578.03; PN-ISO 6060:2006; PN-ISO 15705:2005; PN-EN ISO 5815-1:2019-12; PN-EN 1899-2:2002; PN-ISO 5664:2002 | Waste water | See scope document |
| 7 | PN-ISO 7150-1:2002; PN–EN 25663:2001; PB-07(F) wyd. VI z dnia 01.02.2017 r.; PN-77/C-04604.02; PN-77/C-04604.08; PB-05(F) wyd. V z dnia 01.02.2017 r.; PB-09(F) wyd. I z dnia 14.02.2017 r. w oparciu o testy HACH LANGE LCK 333; PB-10(F) wyd. I z dnia 14.02.2017 r. w oparciu o testy HACH LANGE LCK 432; PN-EN ISO 5815-1:2019-12; PN-EN 1899-2:2002 | Waste water | See scope document |
| 8 | PN-EN ISO 19458:2007; PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12+A1:2017-04; PN-EN ISO 16266:2009; PN-EN ISO 11731:2017-08+Ap1:2019-12; PN-77/C-04615.07; PN-EN ISO 7899-2:2004; PN-EN ISO 14189:2016-10 | Drinking water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium Usługowo-Badawcze "Biochemik"Piła · ~83 kmPCAShares 4 accredited methods and materialsISO 5667-10:2021-11ISO 8288:2002Drinking water
- Zakład Badania Wód i Ścieków Jacek KubiakŚwierzno · ~130 kmPCAShares 4 accredited methods and materialsISO 5667-10:2021-11ISO 7150-1:2002Drinking water
- Laboratorium Badawcze INTERLABO A.Tomaszewski, M.Tomaszewski Spółka JawnaWarszawa · ~229 kmPCAShares 4 accredited methods and materialsISO 5667-10:2021-11ISO 5667-5:2017-10Drinking water
- Eko-Projekt W. Z. Żywczyk Spółka JawnaOstrowiec Św. · ~337 kmPCAShares 4 accredited methods and materialsEN ISO 19458:2007ISO 5667-10:2021-11Drinking water
- Grupa DALAB Bożek DariuszŁużna · ~434 kmPCAShares 4 accredited methods and materialsISO 5667-10:2021-11ISO 5667-5:2017-10Drinking water
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.