Registers refreshed 2026-11-08.See refresh dates
Poland

SOLVERA Gawel Technology

ul. Łąka 260 E, 36-004, Łąka, Poland

PCA AB 1615ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
4
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 4 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 898-1Mechanical properties of fasteners made of carbon steel and alloy steel - Part 1: Bolts, screws and studs with specified property classes - Coarse thread and fine pitch thread
ISO 6507-1Metallic materials - Vickers hardness test - Part 1: Test method
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.

Scope as published by PCA

2 lines
PCA

ISO/IEC 17025

Active

AB 1615

The scope document we hold says it is valid until 2028-07-28.

View on PCA

Accredited scope, certificate AB 1615

LineMethodMatrixRange
1-Construction products and materials
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1615 Scope of accreditation No. AB 1615 Z ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1615 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 10 z/of 19.03.2025 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ MECHANICZNYCH I FIZYCZNYCH MARIA SZAFRAN Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1615 z dnia 23.04.2020 r. Cykl akredytacji od 05.07.2024 do 28.07.2028 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No. AB 1615 of 23.04.2020 Accreditation cycle from 05.07.2024 to 28.07.2028 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 10, 19.03.2025 1/3 Nazwa i adres / Name and address SOLVERA GAWEL Technology S.A. LABORATORIUM CENTRUM BADAWCZO ROZWOJOWEGO Łąka 260 E 36-004 Łąka Kod identyfikacyjny / Identification code*) Dziedzina i przedmiot badań / Field of testing and item: - J/8 - N/8 - Badania mechaniczne wyrobów i materiałów konstrukcyjnych / Mechanical tests of construction products and materials - Badania właściwości fizycznych wyrobów i materiałów konstrukcyjnych / Tests of physical properties of construction products and materials Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB-07 dostępnym na stronie internetowej www .pca.gov.pl / The identification code according to the Annex to document DAB-07, available at PCA website www.pca .gov.pl AB 1615
-
2PN-EN ISO 6892-1:2020-05; PN-EN ISO 6507-1:2024-04; PN-EN ISO 898-1:2013-06; PN-EN ISO 9227:2023-02Wyroby i materiały konstrukcyjne w tym metale; Elementy złączne; Metale i ich stopy, powłoki na metalach i stopach metalito 50 kN

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Łąka 260 E, Łąka, 36-004, PL

50.39156, 17.21259

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.