Bio-Tech Lab Services

3909 Turf Court North, 21771, Mount Airy, MD, United States

Visit website
A2LA 5476.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 5476.01 · 4 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5476.01) 12/01/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 BIO-TECH LAB SERVICES, LLC 3909 Turf Court North Mount Airy, MD 21771 James Collins Phone: 410 474 2773 CALIBRATION Valid To: October 31, 2027 Certificate Number: 5476.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 5: I. Chemical Parameter/Equipment Range CMC2, 4, 6 (±) Comments CO2 – Measure3 (1 to 20) % CO2 0.79 % CO2 Vaisala GMP221 pH Meters3 (4, 7, 10) pH 0.04 pH Reference pH solutions O2 – Measure (0 to 30) % O2 0.15 % O2 Forensics FD-600 II. Mechanical Parameter/Equipment Range CMC2 (±) Comments Balances & Scales3 (0 to 5000) g 0.01 g Class 1 weight set
1 to 20 % CO2
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5476.01) 12/01/2025 Page 2 of 3 Parameter/Equipment Range CMC2, 6 (±) Comments Pressure Measuring Equipment3 Pneumatic (-10 to 500) inH20 0.058 inH 20 Ashcroft ATE-100, AM2-1 RPM – Measure3 (1 to 190 000) RPM 0.012 % RPM Monarch PLT200 III. Thermodynamics Parameter/Equipment Range CMC2, 4, 6 (±) Comments Relative Humidity3 – Measure (20 to 80) % RH 1.3 % RH Vaisala M170/HMP76 Temperature3 – Measure (-100 to 100) °C (-199 to -101) °C 0.92 °C 0.72 °C Fluke 754, thermocouple type T Fluke 1524, RTD IV. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Stopwatches & Timers3 Up to 23 hr 0.79 s Digital stopwatch ___________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration.
-10 to 500 inH20
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5476.01) 12/01/2025 Page 3 of 3 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, ( e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, the value is defined as the percentage of reading, unless otherwise noted. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
4ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3909 Turf Court North, Mount Airy, MD, 21771, US

39.37659, -77.15491

Open in Maps