CENTRO DE TRANSFERENCIAS

Ctra. de Cabezón, km. 6,200 - Pol. Los Barriales, 47155, Santovenia de Pisuerga, Spain

ENAC 446/LE888ISO/IEC 17025Register refreshed 46 days ago

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
12
ENAC certificate
1
Site in our directory
1
ENAC accredited scope

What this lab is accredited for

Our reading of the ENAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 12 standard numbers and the 11 official names we hold. When no standard matches, it searches the method text of every scope line.

EN7
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 10390
EN 12457-4Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 4: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle size below 10 mm (without or with size reduction)
EN 15169Characterization of waste - Determination of loss on ignition in waste, sludge and sediments
EN 15216Environmental solid matrices - Determination of total dissolved solids (TDS) in water and eluates
EN 15936Soil, waste, treated biowaste and sludge - Determination of total organic carbon (TOC) by dry combustion
EN 27888Water quality - Determination of electrical conductivity
ISO5
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 11465Sludge and solid environmental matrices - Determination of dry residue or water content and calculation of the dry matter fraction on a mass basis
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 14911Water quality - Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography - Method for water and waste water

Read from the scope as published by ENAC. Register refreshed 2026-10-10.

Scope as published by ENAC

4 lines
ENAC

ISO/IEC 17025

Active

446/LE888

View scope

Accredited scope, certificate 446/LE888

LineMethodMatrixRange
1UNE-EN ISO/IEC 17025:2017; SM 4500 H+B; UNE-EN 27888; SM 2540 C; UNE-EN 15216Aguas continentales; Aguas residuales (industriales y lixiviados); Residuos sólidos-
2UNE-ISO 9297; SM 4500-F NH3; UNE-EN 1484; UNE-EN ISO 11885; UNE-EN-ISO 10304-1; UNE-EN-ISO 14911; SM 4500 H+B; UNE-EN 27888; SM 2540 C; UNE-EN 15216Aguas continentales; Aguas residuales (industriales y lixiviados)See scope document
3UNE-ISO 9297; UNE-EN 1484; UNE-EN ISO 11885; UNE-EN-ISO 10304-1; UNE-EN ISO 14911; UNE-EN 10390; UNE-ISO 11465; UNE-EN 15169; UNE-EN 15936Aguas residuales (industriales y lixiviados); Residuos sólidos0.04 to mg/l
4SM 4500 H+B; UNE EN 27888; SM 2540 C; UNE-EN 15216; SM 4500-F NH3; UNE-EN 1484; UNE ISO 9297; UNE-EN ISO 11885; UNE-EN ISO 10304-1; UNE-EN ISO 14911; UNE-EN 12457-4lixiviados-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Ctra. de Cabezón, km. 6,200 - Pol. Los Barriales, Santovenia de Pisuerga, 47155, ES

41.69365, -4.68960

Open in Maps

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.