Registers refreshed 2026-11-20.See refresh dates
United Kingdom

Lucion Ground Engineering

Newark Road, PE1 5UA, Peterborough, United Kingdom

Visit website
UKAS 8180ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
6
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.

BS 1377-2
BS 1377-7
ISO 17892-1Geotechnical investigation and testing - Laboratory testing of soil - Part 1: Determination of water content
ISO 17892-4Geotechnical investigation and testing - Laboratory testing of soil - Part 4: Determination of particle size distribution
ISO 17892-8Geotechnical investigation and testing - Laboratory testing of soil - Part 8: Unconsolidated undrained triaxial test
ISO 17892-12Geotechnical investigation and testing - Laboratory testing of soil - Part 12: Determination of liquid and plastic limits

Read from the scope as published by UKAS. Register refreshed 2026-11-20.

Scope as published by UKAS

2 lines
UKAS

ISO/IEC 17025

Active

8180

View scope

Accredited scope, certificate 8180

LineMethodMatrixRange
1BS EN ISO 17892-1:2014; BS EN ISO 17892:12:2018; BS EN ISO 17892-12:2018; BS EN ISO 17892-4:2016 Particle size distribution - dry sieving BS EN ISO 17892-4:2016; BS 1377-2Water; water; OILS-
2BS EN ISO 17892-8:2018 Undrained shear strength - triaxial compression with multistage loading and without measurement of pore pressure BS 1377-7:1990; BS 1377-2; BS 1377-7; ISO/IEC 17025:20175 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 17892-8:2018 Undrained shear strength - triaxial compression with multistage loading and without measurement of pore pressure BS 1377-7:1990water; OILS-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Newark Road, Peterborough, PE1 5UA, GB

52.57414, -0.21239

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.