South Korea
Element Materials Technology Suwon.
Dongbu-ro 221-gil 5, Cheioin-gu, Yongin-si, 17141, South Korea, Yongin-si, South Korea
A2LA|2041.04ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
5
Locations
2
Contact this laboratory
Work at Element Materials Technology Suwon.?
Claim this profile to keep it accurate.
Claim this profileRegister record
- A2LACollected
- 2041.04Active
Certificates and scope
1A2LA
ISO/IEC 17025
Active2041.04
Accredited scope, certificate 2041.04
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| electrical | ISO/IEC 17025:2017; CFR 47, FCC Part 15B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); CFR 47 FCC Parts 22, 24, 25, 27, 30, 74, 90, 95, 96, 97, 101 (using ANSI/TIA-603-E, ANSI C63.26:2015); 47 CFR FCC Parts 15C (using ANSI C63.10: 2013, ANSI C63.10: 2020); 47 CFR FCC Part 15E (using ANSI C63.10: 2013 and KDB Publication 905462 D02 (v02)); 47 CFR FCC Part 15F (using ANSI C63.10: 2013); ANSI C63.10:2020; RSS-111; RSS-112; RSS-117; RSS-119; RSS-123; RSS-125; RSS-127; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-135; RSS-137; RSS-139; RSS-140; RSS-141; RSS-142; RSS-170; RSS-181; RSS-182; RSS-191; RSS-192; RSS-194; RSS-195; RSS-196; RSS-197; RSS-199; RSS-210; RSS-211; RSS-215; RSS-216; RSS-220; RSS-222; RSS-236; RSS-238; RSS-243; RSS-244; RSS-247; RSS-248; RSS-251; RSS-252; RSS-287; RSS-288; RSS-310; RSS-GEN | Wireless device | to 220 GHz |
| electrical | RSS-102; RSS-102.SAR.MEAS; SPR-APD-Issue1; FCC KDB 447498 D01; FCC KDB 643646 D01; FCC KDB 616217 D04; FCC KDB 865664 D01, D02; FCC KDB 941225 D01, D05, D05A, D06, and D07; EN 50385:2017; EN 50401:2017; EN 62232:2017; EN 50401:2017; EN 50360:2017; EN 50566:2017; EN 62209-1:2016; EN 62209-2:2010 + A1:2019; EN 62479:2010; EN 50663:2017; IEC TR 62630; IEEE Std 1528:2013; IEEE C95.1:2019; IEEE C95.3:2021; IEEE Std C95.3.1 (2010); IEC 62209-1 Ed. 2:2016; IEC 62209-2:2010 + AMD 1; IEC/IEEE 62209-1528:2020; EN IEC/IEEE 62209-1528; IEC 62311:2019; EN IEC 62311:2020; IEC 62479:2010; IEC PAS 63083:2017; IEC/IEEE 63195-1:2022; IEC TR 62630:2010; IEC TR 63170:2018; Australian Communications Authority Radio Communications (Electromagnetic Radiation – Human Exposure) Standard 2014; Australia Radio Communications Equipment (General) Rules 2021; ARPANSA RPS S-1(Rev.1):2021; AS/NZS 2772.2:2016; RRA Public Notification 2018-18, December 7, 2018; RRA Public Notification 2021-22, November 29, 2021; KS C 3370-1; KS C 3370-2; ANSI C63.4:2014 | - | to 40000 MHz |
| electrical | FCC MP-5:1986; ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI C63.26:2015; IEEE Std 1528:2013 | - | to 220000 MHz |
| electrical | - | - | - |
| electrical | Korea KS X 3123(2019); KS X 3142 (2019); Unlicensed Radio Equipment Established Without Notice (MSIT Public Notification 2018-38); Technical Requirements for Radio Equipment (Enforcement Decree of MSIT No.1); EN 300 220-1; EN 300 220-2; EN 300 220-3-1; EN 300 220-3-2; EN 300 220-4; EN 300 328; EN 300 440; EN 301 893; EN 302 208; EN 301 908-1; RSS-102; RSS-102.SAR.MEAS; RSS-102.IPD.MEAS; RSS-102.NS.MEAS; SPR-003; SPR-APD-Issue1; FCC KDB 447498 D01; FCC KDB 643646 D01; FCC KDB 616217 D04; FCC KDB 865664 D01, D02; FCC KDB 941225 D01, D05, D05A, D06, and D07; EN 50385:2017; EN 50401:2017; EN 62232:2017; EN 50401:2017; EN 50360:2017; EN 50566:2017; EN 62209-1:2016; EN 62209-2:2010 + A1:2019; EN 62479:2010; EN 50663:2017; IEC TR 62630; IEEE Std 1528:2013; IEEE C95.1:2019; IEEE C95.3:2021; IEEE Std C95.3.1 (2010); IEC 62209-1 Ed. 2:2016; IEC 62209-2:2010 + AMD 1; IEC/IEEE 62209-1528:2020; EN IEC/IEEE 62209-1528; IEC 62311:2019; EN IEC 62311:2020; IEC 62479:2010; IEC PAS 63083:2017; IEC/IEEE 63195-1:2022; IEC TR 62630:2010; IEC TR 63170:2018; Australian Communications Authority Radio Communications (Electromagnetic Radiation – Human Exposure) Standard 2014; Australia Radio Communications Equipment (General) Rules 2021; ARPANSA RPS S-1(Rev.1):2021; AS/NZS 2772.2:2016; RRA Public Notification 2018-18, December 7, 2018; RRA Public Notification 2021-22, November 29, 2021; KS C 3370-1; KS C 3370-2; ANSI C63.19:2019; CTIA Test Plan for Hearing Aid Compatibility v.3.1.1 (2017); RSS-HAC; ANSI/TIA-5050-2018 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Dongbu-ro 221-gil 5, Cheioin-gu, Yongin-si, 17141, South Korea, Yongin-si, KR
37.24057, 127.17856
Open in MapsOther Locations
1 other site in this organization
Labs with overlapping accredited scope in South Korea
Accreditation data collected from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.