Registers refreshed 2026-11-20.See refresh dates
United States

Duke University Medical Center - Duke Human Vaccine Institute

27 Alexandria Way, 27709, Durham, NC, United States

Visit website
A2LA 3614.01ISO/IEC 17043Register refreshed 2026-11-20
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3614.01 · 4 lines

LineMethodMatrixRange
1-peripheral blood mononuclear cells (PBMCs); peptides (CMV and CEF)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3614.01) Revised 3/4/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17043:2023 DUKE UNIVERSITY MEDICAL CENTER – DUKE HUMAN VACCINE INSTITUTE 27 Alexandria Way, Durham, NC 27703 Thomas Denny Phone: 919 681 1023 Email: thomas.denny@duke.edu PROFICIENCY TESTING PROVIDER Valid To: August 31, 2026 Certificate Number: 3614.01 In recognition of the successful completion of the A2LA evaluation process, this proficiency testing provider has been found to meet ISO/IEC 17043:2010, “Conformity Assessment - General Requirements for the competence of Proficiency Testing Providers”. Accreditation is granted to this provider to provide proficiency testing samples in the following programs: PROGRAM NAME FREQUENCY SCHEME DESCRIPTION TECHNIQUES USED TO DETERMINE ASSIGNED VALUE/ UNCERTAINTY CATEGORY B: BIOLOGICIAL AND CLINICAL PROPERTIES EQAPOL ELISpot EQA Program 1 Twice per year Sites receive cryopreserved peripheral blood mononuclear cells (PBMCs) and peptides (CMV and CEF). The PBMCs selected for each EP round have varying reactivities to the provided peptides. Sites run their in-house ELISpot assay to measure IFN-y production. In addition, sites are provided with an EQAPOL ELISpot assay to run using the cells peptides. Assigned values and uncertainties determined by consensus values from participants 1 Surgical Oncology Research Facility (SORF), 915 S. LaSalle St., Durham, NC 27701
-
2-human AB serum matrix
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3614.01) Revised 3/4/2025 Page 2 of 3 PROGRAM NAME FREQUENCY SCHEME DESCRIPTION TECHNIQUES USED TO DETERMINE ASSIGNED VALUE/ UNCERTAINTY EQAPOL Flow Cytometry EQA Program 2 Twice per year For each EP round, EQAPOL provides all of the reagents to run each assay including: PBMCs selected based on their cytokine production following stimulation, stimulation plates containing lyophilized peptides (CEF and CMV) and staining plates containing lyophilized antibodies and all other necessary instrument set-up and staining reagents. Sites are required to run the assay using the EQAPOL provided kit and protocol. Currently the EQA program assesses proficiency using an 8- color Intracellular Cytokine Staining (ICS) assay that measures IFN-y, IL-2, TNF-a and CD107a. Assigned values and uncertainties determined by consensus values from participants EQAPOL Multiplex EQA Program2 Twice per year For each EP round, Multiplex program participants receive 21 test samples containing known amounts of five cytokines (IL-2, IL-10, IL-6, TNFγ, IFNγ) in a human AB serum matrix. Sites assay the samples for the cytokines using the Multiplex (Luminex or MSD) assay of their choosing. Results are uploaded to the EQAPOL portal. Assigned values and uncertainties determined by consensus values from participants EQAPOL Luminex EQA Program3 Twice per year For each EP round, Luminex program participants receive a de-identified custom 5-plex Luminex-bead assay kit (blinded to the reagent manufacturer), which includes all necessary reagents to run the assay, from a vendor selected by CIC/NIAID. In addition to these kits, sites will receive 21 test samples containing known amounts of the five cytokines measured by the assay in a human AB serum matrix. Assigned values and uncertainties determined by consensus values from participants 2 Surgical Oncology Research Facility (SORF), 915 S. LaSalle St., Durham, NC 27701 3 909 S. LaSalle St., Global Health Research Building (GHRB), Durham, NC 27701
-
3-HIV-positive and negative samples; HIV positive samples; stabilized whole blood specimens; HIV-1 positive plasma samples
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3614.01) Revised 3/4/2025 Page 3 of 3 PROGRAM NAME FREQUENCY SCHEME DESCRIPTION TECHNIQUES USED TO DETERMINE ASSIGNED VALUE/ UNCERTAINTY Virology Quality Assurance (VQA) Proficiency Testing for HIV-1 RNA Viral Load Six times per year Five-member panels of HIV-positive and negative samples are shipped to sites. Samples are spiked with known quantity of HIV-1. The sites measure the HIV-1 viral load on the samples are report the data back to the VQA program. Measure of how closely a laboratory estimate of viral load is to the expected median Log10 value VQA Proficiency Testing Program for Qualitative HIV-1 Nucleic Acid Testing (NAT) Four times per year Five-member panels of HIV-positive and negative samples are shipped to sites. Samples are spiked with known quantity of HIV-1. The sites are asked to identify the samples as HIV-1 positive or negative by measuring DNA and report the data back to the VQA program. Assessing whether a site correctly classified a sample. No statistics are involved. EQAPOL Limiting Antigen Avidity (LAg) Proficiency Testing Program Twice per year HIV positive samples are shipped to sites for them to assess the HIV infection recency status. These samples are run on either a Sedia or Maxim kit and results are uploaded into the EQAPOL portal. Assigned values and uncertainties are determined by consensus values from participants and correctly identifying sample classification Immunology Quality Assessment (IQA) CD4/CD8 Immunophenotyping Flow Cytometry Quality Assessment Program4 Six times per year Participating sites receive 2 coded stabilized whole blood specimens per each PT. Sites measure and report the percent of T cell lymphocytes and the count [per microliter] for the following phenotypes [if available on the instrument platform]: Immunology Quality Assessment (IQA) CD4/CD8 Immunophenotyping Flow Cytometry Quality Assessment Program4 Virology Quality Assurance (VQA) Proficiency Testing for Drug Resistant Mutations 4 Twice per year Five-member panels of HIV-1 positive plasma samples with known HIV-1 drug resistance mutations are shipped to sites. The sites perform genotyping assays on the samples and report the nucleotide sequence and amino acid mutation profile of each sample. For each panel member, a consensus reference sequence is created from the data submitted by all sites. Sites are scored by assigning a p- value to the number of disagreements between the site’s individual sequence and the consensus. 4 MSRBII, 2 Genome Court, Durham, NC 27701
-
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the proficiency testing schemes to which this accreditation applies, please refer to the provider’s Scope of Accreditation. Accredited Proficiency Testing Provider A2LA has accredited DUKE UNIVERSITY MEDICAL CENTER - DUKE HUMAN VACCINE INSTITUTE Durham, NC This accreditation covers the specific proficiency testing schemes listed on the agreed upon Scope of Accreditation. This provider is accredited in accordance with the recognized International Standard ISO/IEC 17043: 2023 Conformity assessment - General requirements for the competence of proficiency testing providers. This accreditation demonstrates technical competence for a defined scope and the operation of a quality management system. Presented this 4th day of March 2025. _______________________ Mr. Trace McInturff, Vice President and CEO For the Accreditation Council Certificate Number 3614.01 Valid to August 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

27 Alexandria Way, Durham, NC, 27709, US

35.99665, -78.90181

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.