Navair Technologies
Mississauga, Canada
Visit website- Scope lines
- 22
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 22 scope lines.
A2LA certificate 5941.01 · 22 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 1 of 21
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
NAVAIR TECHNOLOGIES INC.
6375 Dixie Road, Unit 7
Mississauga, Ontario, CANADA L5T 2E7
John Raposo Phone: 905 565 1583 ext. 226
CALIBRATION
Valid To: September 30, 2026 Certificate Number: 5941.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 8:
I. Acoustical Quantities
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Sound Pressure –
Measuring Equipment
(94, 104 ,114) dB
Simulation
Measure
(94, 104 ,114) dB
31.5 Hz
63 Hz to 12.5 kHz
16 kHz
10 Hz to 20 kHz
250 Hz
1000 Hz
0.17 dB
0.16 dB
0.17 dB
0.02 dB
0.08 dB
0.15 dB
Sound level calibrator
Function generator
DMM & simulated
microphone
Reference microphone | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 2 of 21
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
DC Voltage– Generate,
Fixed Points
100 mV
1 V
10 V
100 V
1000 V
4.0 µV/V
1.0 µV/V
0.25 µV/V
1.0 µV/V
2.0 µV/V
DC voltage reference &
reference voltage divider
DC voltage reference
DC voltage reference &
reference voltage divider
DC Voltage3– Generate
Up to 220 mV
220 mV to 2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
2.9 µV/V + 0.2 µV
2.0 µV/V + 0.4 µV
1.3 µV/V + 1.4 µV
1.2 µV/V + 2.1 µV
2.1 µV/V + 22 µV
2.5 µV/V + 230 µV
Multifunction calibrator
DC Voltage – Measure,
Fixed Points
100 mV
1 V
10 V
100 V
1000 V
4.0 µV/V
1.0 µV/V
0.25 µV/V
1.6 µV/V
2.1 µV/V
DC ref, ref V divider, null
meter
DC ref comparison, null
meter
DC ref, ref V divider, null
meter
DC Voltage3 –Measure
Up to 100 mV
(>0.1 to 1) V
(>1 to 10) V
(>10 to 100) V
(>100 to 1000) V
(1 to 10) kV
(10 to 70) kV
5.6 µV/V + 0.15 µV
3.6 µV/V + 0.34 µV
3.0 µV/V + 0.8 µV
5.2 µV/V + 35 µV
5.2 µV/V + 150 µV
0.031 % + 0.34 V
0.032 % + 3.4 V
Long scale voltmeter
HV meter
HV meter & HV divider | to 70 kV |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 3 of 21
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
DC Current – Measure
(0 to 20) pA
(20 to 200) pA
200 pA to 2 nA
(2 to 20) nA
(20 to 200) nA
100 nA to 1 µA
(1 to 10) µA
(10 to 100) µA
(100 to 10 000) µA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 10) A
(10 to 100) A
0.58 % + 13 fA
0.58 % + 120 fA
0.23 % + 620 fA
0.23 % + 4.9 pA
0.23 % + 49 pA
6 µA/A + 0.8 pA
4.1 µA/A + 4.5 pA
4.2 µA/A + 59 pA
3.5 µA/A + 650 pA
3.6 µA/A + 3.6 nA
4.3 µA/A + 43 nA
6.9 µA/A + 1 µA
7.1 µA/A + 7.2 µA
31 µA/A + 310 µA
Pico ammeter
Long scale DMM & standard
resistors
DC current comparator,
standard resistor & voltmeter
DC Current – Generate
(2 to 20) A
(20 to 100) A
(100 to 1000) A
0.023 % + 2.5 mA
0.023 % + 15 mA
0.39 % + 0.5 A
Transconductance amplifier
& calibrator
Current coil & calibrator
DC Current3 –
Generate
(0 to 20) pA
(20 to 200) pA
200 pA to 2 nA
(2 to 20) nA
(20 to 200) nA
200 nA to 2 µA
(2 to 20) µA
(20 to 200) µA
(200 to 2000) µA
(2 to 20) mA
(20 to 200) mA
200 mA to 2A
(1 to 3) A
(3 to 11) A
(11 to 20) A
0.85 % + 1.7 fA
0.057 % + 8.1 fA
0.11 % + 22 fA
0.006 % + 120 fA
0.002 % + 0.4 pA
0.002 % + 3.5 nA
0.002 % + 34 nA
100 µA/A + 3 nA
40 µA/A + 13 nA
40 µA/A + 130 nA
58 µA/A + 1.3µA
40 µA/A + 21 µA
0.039 % + 860 µA
0.05 % + 1.8 mA
0.1 % + 13 mA
DC calibrator with
precision resistors applied to
virtual ground meters
Multifunction calibrator | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 4 of 21
Parameter/Frequency
Range
CMC2, 4, 5, 7 (±)
Comments
Capacitance – Generate
Fixed Points
100/120/1000 Hz
100/120/1000 Hz
10 pF
100 pF
1000 pF
10 nF
100 nF
1 µF
10 µF
10 µF
100 µF
1 mF
10 mF
1F
0.5 µF/F
2.0 µF/F
2.0 µF/F
17 µF/F
38 µF/F
70 µF/F
0.02 %
0.29 %
0.29 %
0.30 %
0.45 %
0.50 %
Primary level
capacitors
Precision bridge &
capacitors at 23 °C +/-
0.1 °C
Navair 10 µF capacitor
4T capacitance
simulator
Capacitance3 – Generate
1 kHz
100 Hz
80 Hz
50 Hz
20 Hz
DC
(0.19 to 3.299 99) nF
(1.1 to 3.299 99) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.999) mF
(33 to 110) mF
0.39 % + 6.0 pF
0.39 % + 9.3 pF
0.19 % + 12 pF
0.19 % + 72 pF
0.19 % + 110 pF
0.19 % + 360 pF
0.19 % + 1.2 nF
0.19 % + 3.7 nF
0.19 % + 11 nF
0.31 % + 49 nF
0.35 % + 170 nF
0.35 % + 530 nF
0.35 % + 1.7 µF
0.35 % + 5.3 µF
0.37 % + 17 µF
0.59 % + 80 µF
0.8 % + 340 µF
Multifunction
calibrator | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 5 of 21
Parameter/Frequency
Range
CMC2, 4, 7 (±)
Comments
Capacitance– Measure,
Fixed Points
1 kHz
10 pF
100 pF
1000 pF
10 nF
100 nF
1 µF
1 µF/F
2.0 µF/F
2.0 µF/F
16 µF/F
36 µF/F
69 µF/F
AH 2500A/2700A &
reference capacitors
Capacitance3– Measure
1 kHz
100 Hz
80 Hz
50 Hz
20 Hz
DC
(0.19 to 3.299 99) nF
(1.1 to 3.299 99) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.999) mF
(33 to 110) mF
0.025 % + 0.1 pF
0.016 % + 0.2 pF
0.019 % + 0.6 pF
0.019 % + 2 pF
0.019 % + 6 pF
0.019 % + 20 pF
0.033 % + 0.11 nF
0.033 % + 0.36 nF
0.033 % + 1.1 nF
0.033 % + 3.6 nF
0.04 % + 14 nF
0.04 % + 44 nF
0.07 % + 0.3 µF
0.1 % + 1.1 µF
0.02 % + 0.9 µF
0.02 % + 2.3 µF
0.07 % + 22 µF
LCR bridge
Charge technique using
a DCI source & long
scale DMM | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 6 of 21
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Resistance – Measure,
Fixed Points
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 µΩ/Ω
5 µΩ/Ω
1 µΩ/Ω
0.5 µΩ/Ω
1.0 µΩ/Ω
1.0 µΩ/Ω
1.0 µΩ/Ω
0.5 µΩ/Ω
1.0 µΩ/Ω
2.0 µΩ/Ω
3.0 µΩ/Ω
8.0 µΩ/Ω
23 µΩ/Ω
83 µΩ/Ω
250 µΩ/Ω
620 µΩ/Ω
DCC bridge reference
resistors & range
extender in oil or air
bath
Teraohmmeter &
air bath
Resistance – Measure
(0 to 12) Ω
(12 to 120) Ω
(120 to 1200) Ω
(1.2 to 12) kΩ
(12 to 120) kΩ
120 kΩ to 1.2 MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
(20 to 200) MΩ
200 MΩ to 2GΩ
(2 to 20) GΩ
(20 to 200) GΩ
200 GΩ to 2 TΩ
17 µΩ/Ω + 0.042 mΩ
12 µΩ/Ω + 0.39 mΩ
9.3 µΩ/Ω + 1.4 mΩ
9.3 µΩ/Ω + 14 mΩ
9.3 µΩ/Ω + 110 mΩ
14 µΩ/Ω + 2.7 Ω
50 µΩ/Ω + 120 Ω
580 µΩ/Ω + 7.4 kΩ
93 µΩ/Ω
170 µΩ/Ω
460 µΩ/Ω
690 µΩ/Ω
1200 µΩ/Ω
Long scale DMM
Teraohmmeter
direct measurement | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 7 of 21
Parameter/Equipment
Range
CMC2, 4, 5, 7 (±)
Comments
Resistance – Generate,
Fixed Points
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
40 µΩ/Ω
30 µΩ/Ω
1.0 µΩ/Ω
0.50 µΩ/Ω
1.0 µΩ/Ω
1.0 µΩ/Ω
1.0 µΩ/Ω
0.50 µΩ/Ω
1.0 µΩ/Ω
2.0 µΩ/Ω
3.0 µΩ/Ω
5.0 µΩ/Ω
30 µΩ/Ω
0.040 %
0.060 %
0.10 %
21 µΩ/Ω
21 µΩ/Ω
9 µΩ/Ω
9 µΩ/Ω
5.7 µΩ/Ω
5.7 µΩ/Ω
5.5 µΩ/Ω
5.5 µΩ/Ω
7.5 µΩ/Ω
7 µΩ/Ω
11 µΩ/Ω
14 µΩ/Ω
31 µΩ/Ω
39 µΩ/Ω
96 µΩ/Ω
Standard resistors
Multifunction calibrator | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 8 of 21
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33to 110) Ω
(110 to 330) Ω
330 Ω to 1.1kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
31 µΩ/Ω + 0.0005 Ω
25 µΩ/Ω + 0.001 Ω
22 µΩ/Ω + 0.0015 Ω
22 µΩ/Ω + 0.0034 Ω
22 µΩ/Ω + 0.0082 Ω
22 µΩ/Ω + 0.034 Ω
22 µΩ/Ω + 0.082 Ω
22 µΩ/Ω + 0.34 Ω
22 µΩ/Ω + 0.82 Ω
22 µΩ/Ω + 4 Ω
25 µΩ/Ω + 10 Ω
47 µΩ/Ω + 66 Ω
100 µΩ/Ω + 360 Ω
110 µΩ/Ω + 3.4 kΩ
390 µΩ/Ω + 14 kΩ
2000 µΩ/Ω + 0.31 MΩ
1.2 % + 0.87 MΩ
Multifunction
calibrator | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 9 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Voltage3 – Generate
(1 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(500 to 1000) kHz
10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(500 to 1000) kHz
10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(500 to 1000) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(500 to 1000) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(500 to 1000) kHz
240 µV/V + 4 µV
91 µV/V + 4 µV
81 µV/V + 4 µV
200 µV/V + 4 µV
500 µV/V + 5.1 µV
1100 µV/V + 10 µV
1400 µV/V + 20 µV
2700 µV/V + 20 µV
240 µV/V + 4.5 µV
91 µV/V + 4.2 µV
81 µV/V + 4.2 µV
200 µV/V + 4.4 µV
500 µV/V + 6.1 µV
1100 µV/V + 12 µV
1400 µV/V + 23 µV
2700 µV/V + 26 µV
240 µV/V + 17 µV
90 µV/V + 9 µV
58 µV/V + 8.3 µV
120 µV/V + 9.6 µV
310 µV/V + 24 µV
66 µV/V + 34 µV
1400 µV/V + 56 µV
2700 µV/V + 100 µV
240 µV/V + 140 µV
90 µV/V + 15 µV
43 µV/V + 8.0 µV
67 µV/V + 10 µV
86 µV/V + 30 µV
340 µV/V + 80 µV
1000 µV/V + 200 µV
1700 µV/V + 300 µV
240 µV/V + 400 µV
90 µV/V + 150 µV
42 µV/V + 50 µV
67 µV/V + 100 µV
84 µV/V + 200 µV
260 µV/V + 600µV
1000 µV/V + 2000 µV
1500 µV/V + 3200 µV
Multifunction
calibrator | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 10 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Voltage3 – Generate
(cont)
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(500 to 1000) kHz
(0.04 to 1) kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
(0.4 to 1) kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
240 µV/V + 400 µV
90 µV/V + 150 µV
42 µV/V + 50 µV
67 µV/V + 100 µV
84 µV/V + 200 µV
255 µV/V + 600 µV
1000 µV/V + 2000 µV
1500 µV/V + 3200 µV
80 µV/V + 2.6 mV
150 µV/V + 5.5 mV
900 µV/V + 34 mV
4400 µV/V + 130 mV
8000 µV/V + 240 mV
91 µV/V + 24 mV
170 µV/V + 42 mV
600 µV/V + 140 mV
600 µV/V + 140 mV
2300 µV/V + 550 mV
Multifunction
calibrator | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 11 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Current – Measure
2 mA
20 mA
200 mA
2 A
10 A
20A
2 mA
20 mA
200 mA
2 A
10 A
20A
2 mA
20 mA
200 mA
2 A
10 A
20A
2 mA
20 mA
200 mA
2 A
10 A
20 A
2 mA
20 mA
200 mA
2 A
10 A
20 A
40 Hz
500 Hz
1 kHz
5 kHz
10 kHz
35 µA/A
29 µA/A
27 µA/A
29 µA/A
38 µA/A
43 µA/A
35 µA/A
25 µA/A
23 µA/A
25 µA/A
36 µA/A
40 µA/A
35 µA/A
25 µA/A
23 µA/A
25 µA/A
36 µA/A
40 µA/A
35 µA/A
27 µA/A
25 µA/A
27 µA/A
41 µA/A
46 µA/A
35 µA/A
32 µA/A
27 µA/A
29 µA/A
70 µA/A
73 µA/A
ACV measurement
standard & AC shunts | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 12 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Current – Measure
(cont)
(10 to 100) µA
(100 to 1000) µA
(1 to 10) mA
(10 to 100) mA
(100 to 1000) mA
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
0.17 % + 0.032 µA
0.069 % + 0.022 µA
0.069 % + 0.022 µA
0.069 % + 0.022 µA
0.17 % + 0.27 µA
0.069 % + 0.17 µA
0.035 % + 0.14 µA
0.069 % + 0.17 µA
0.17 % + 2.7 µA
0.069 % + 1.7 µA
0.035 % + 1.4 µA
0.069 % + 1.7 µA
0.17 % + 27 µA
0.069 % + 17 µA
0.035 % + 14 µA
0.069 % + 17 µA
0.19 % + 290 µA
0.092 % + 190 µA
0.12 % + 220 µA
0.35 % + 450 µA
Long scale DMM | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 13 of 21
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Electrical Simulation of
Thermocouple
Temperature Indicators3–
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.35 °C
0.16 °C
0.15 °C
0.16 °C
0.16 °C
0.21 °C
0.16 °C
0.15 °C
0.16 °C
0.26 °C
0.25 °C
0.17 °C
0.16 °C
0.21 °C
0.34 °C
0.29 °C
0.19 °C
0.17 °C
0.17 °C
0.21 °C
0.40 °C
0.26 °C
0.25 °C
0.29 °C
0.33 °C
0.27 °C
0.27 °C
0.33 °C
0.44 °C
0.20 °C
0.16 °C
0.09 °C
Multifunction calibrator | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 14 of 21
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Electrical Simulation of
RTD Temperature
Indicators3 –
PT 385 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.035 °C
0.035 °C
0.048 °C
0.061 °C
0.068 °C
0.081 °C
0.15 °C
Multifunction calibrator
Signal Conditioner
Amplifiers
10 Hz to 10 kHz
Charge
Voltage
0.05 %
0.02 %
Function generator
DMM & capacitor
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Voltage – Measure
(0 to 2.2) mV
(2.2 to 7) mV
(7 to 22) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.17 % + 1 µV
0.074 % + 1 µV
0.042 % + 1 µV
0.082 % + 1 µV
0.12 % + 1.3 µV
0.23 % + 2.1 µV
0.26 % + 4.1 µV
0.50 % + 4.1 µV
0.086 % + 1 µV
0.037 % + 1 µV
0.021 % + 1 µV
0.041 % + 1 µV
0.061 % + 1.3 µV
0.12 % + 2.1 µV
0.14 % + 4.1 µV
0.36 % + 4.3 µV
0.030 % + 1 µV
0.019 % + 1 µV
0.011 % + 1 µV
0.021 % + 1 µV
0.031 % + 1.3 µV
0.82 % + 2.2 µV
0.10 % + 4.2 µV
0.26 % + 4.6 µV
AC measurement
standard | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 15 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Voltage – Measure
(cont)
(22 to 70) mV
(70 to 220) mV
(220 to 700) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.024 % + 1 µV
0.013 % + 1 µV
0.007 % + 1 µV
0.013 % + 1.1 µV
0.026 % + 1.4 µV
0.053 % + 2.4 µV
0.068 % + 4.5 µV
0.13 % + 4.9 µV
0.021 % + 1.1 µV
0.0089 % + 1 µV
0.0044 % + 1 µV
0.0074 % + 1.2 µV
0.016 % + 1.6 µV
0.028 % + 2.6 µV
0.040 % + 4.9 µV
0.12 % + 6.7 µV
0.021 % + 2.1 µV
0.0078 % + 1.2 µV
0.0038 % + 1 µV
0.0056 % + 1.4 µV
0.0084 % + 18 µV
0.021 % + 3.5 µV
0.034 % + 6.4 µV
0.12 % + 12 µV
AC measurement
standard | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 16 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Voltage – Measure
(cont)
(0.7 to 2.2) V
(2.2 to 7) V
(7 to 22) V
(22 to 70) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.020 % + 4.4 µV
0.0066 % + 1.5 µV
0.0024 % + 1 µV
0.0046 % + 1.1 µV
0.0071 % + 1.7 µV
0.016 % + 4.4 µV
0.026 % + 6.8 µV
0.090 % + 27 µV
0.020 % + 1.4 µV
0.0070 % + 1 µV
0.0024 % + 1 µV
0.0046 % + 1 µV
0.0071 % + 1 µV
0.016 % + 1.5 µV
0.026 % + 3.3 µV
0.090 % + 11 µV
0.022 % + 4.9 µV
0.0081 % + 1.8 µV
0.0037 % + 1 µV
0.0057 % + 1.3 µV
0.0087 % + 1.9 µV
0.022 % + 4.9 µV
0.047 % + 10 µV
0.15 % + 34 µV
0.022 % + 16 µV
0.0082 % + 5.8 µV
0.0044 % + 3.1µV
0.0066 % + 4.6 µV
0.011 % + 7.8 µV
0.022 % + 16 µV
0.051 % + 36 µV
0.15 % + 110 µV
AC measurement
standard | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 17 of 21
Parameter/Range
Frequency
CMC2, 4, 5, 7 (±)
Comments
AC Voltage – Measure
(cont)
(70 to 220) V
(220 to 700) V
(700 to 1000) V
(1 to 10) kV
(10 to 50) kV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
60 Hz
60 Hz
0.022 % + 49 µV
0.0082 % + 18 µV
0.0043 % + 10 µV
0.0080 % + 18 µV
0.011 % + 25 µV
0.026 % + 58 µV
0.070 % + 160 µV
0.022 % + 160 µV
0.017 % + 82 µV
0.0051 % + 36 µV
0.015 % + 110 µV
0.085 % + 600 µV
0.022 % + 220 µV
0.012 % + 120 µV
0.0048 % + 50 µV
0.015 % + 150 µV
0.085 % + 850 µV
0.08 % + 1.4 V
0.09 % + 6.6 V
AC measurement
standard
HV voltmeter & HV
probe
AC Current – Generate
300 A
600 A
1000A
300 A
600 A
1000A
50/60 Hz
50/60 Hz
50/60 Hz
400 Hz
400 Hz
400 Hz
0.36 %
0.35 %
0.36 %
0.84 %
0.83 %
0.83 %
Current coil &
calibrator | ||
| 18 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 18 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Current3– Generate
(10 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(20 to 100) A
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(0.02 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
(45 to 1000) Hz
0.025 % + 17 nA
0.016 % + 11 nA
0.010 % + 9.3 nA
0.028 % + 13 nA
0.11 % + 68 nA
0.025 % + 96 nA
0.016 % + 71 nA
0.010 % + 59 nA
0.020 % + 160 nA
0.11 % + 890 nA
0.025 % + 960 nA
0.016 % + 710 nA
0.012 % + 280 nA
0.022 % + 500 nA
0.11 % + 7400 nA
0.025 % + 9.6 µA
0.016 % + 7.1 µA
0.010 % + 4.9 µA
0.020 % + 8.0 µA
0.11 % + 34 µA
0.024 % + 89 µA
0.045 % + 180 µA
0.70 % + 1.7 mA
0.046 % + 0.22 mA
0.095 % + 0.48 mA
0.36 % + 1.1 mA
0.12 % + 5.1 mA
0.15 % + 5.2 mA
0.30 % + 5.1 mA
0.15 % + 100 mA
Multifunction
calibrators & trans
conductance
amplifiers | 10 to 100 A |
| 19 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 19 of 21
Parameter/Equipment
Range
CMC2, 4, 5, 7 (±)
Comments
Oscilloscopes3 –
DC:
50 Ω
1 MΩ
Square Wave:
50 Ω
Peak-Peak
1 MΩ
Peak-Peak
Level Sine Wave – Vpp:
50 kHz Reference
Time Marker
(1 to 25) mV
(25 to 110) mV
(0.11 to 2.2) V
(2.2 to 6.6) V
(1 to 25) mV
(25 to 110) mV
(0.11 to 2.2) V
(2.2 to 11) V
(11 to 130) V
(1 to 25) mV
(25 to 110) mV
(0.11 to 2.2) V
(2.2 to 6.6) V
(1 to 25) mV
(25 to 110) mV
(0.11 to 2.2) V
(2.2 to 11) V
(11 to 130) V
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
10 Hz to 10 MHz
(10 to 125) MHz
(125 to 300) MHz
300 MHz to 1.4 GHz
(1.4 to 3) GHz
(3 to 4) GHz
5 s to 50 ms
(20 to100) ms
(50 to 20) ns
10 ns
(5 to 2) ns
0.15 % + 40 µV
0.15 % + 40 µV
0.15 % + 40 µV
0.15 % + 40 µV
0.07 % + 40 µV
0.07 % + 40 µV
0.07 % + 40 µV
0.07 % + 40 µV
0.07 % + 40 µV
0.15 % + 40 µV
0.15 % + 40 µV
0.15 % + 40 µV
0.15 % + 40 µV
0.11 % + 40 µV
0.11 % + 40 µV
0.11 % + 40 µV
0.11 % + 40 µV
0.11 % + 40 µV
0.8 % + 100 µV
1.3 % + 100 µV
2.0 % + 100 µV
0.6 %
0.6 %
1.2 %
2.9 %
3.5 %
5.9 %
15 µs/s
3.4 µs/s
3.4 µs/s
3.4 µs/s
3.4 µs/s
Multifunction
calibrator
oscilloscope option
RF source
Multifunction
calibrator with
oscilloscope option | to 4 GHz |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 20 of 21
III. Mechanical
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Vibration Transducers
Sensitivity
5 Hz
10Hz
(20 to 100) Hz
(100, 159.2) Hz
(200 to 920) Hz
1000 Hz
(2 to 5) kHz
2.5 %
1.5 %
1.3 %
0.6 %
1.1 %
1.5 %
1.7 %
By comparison with
reference accelerometer
IV. Time & Frequency
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
Parameter/Equipment
Range CMC2, 6, 7 (±) Comments
Frequency – Measuring
Equipment & Measure,
Fixed Point
10 MHz
5 x 10-11 Hz/Hz
Rubidium frequency
standard with GPS
Frequency3 –
Measure
Measuring Equipment
1 Hz to 40 GHz
1 Hz to 50 GHz
1 x 10-9 Hz/Hz + 0.1 mHz
1 x 10-9 Hz/Hz + 1 Hz
Frequency counters
Frequency
synthesizers | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5941.01) 2/26/2025 Page 21 of 21
4 The measurands stated are generated using the indica ted instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measuran d in the ranges
indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the
reading plus a fixed floor specification.
5 In the statement of CMC, the value is defined as the percentage of reading.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 The contributions from the “best existing device”, such as resolution and repeatability of the unit under
calibration, are not included in the CMC uncertainties claim.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
NAVAIR TECHNOLOGIES INC.
Mississauga, ON, CANADA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 26th day of February 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 5941.01
Valid to September 30, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations