Registers refreshed 2026-11-20.See refresh dates
Canada

Navair Technologies

Mississauga, Canada

Visit website
A2LA 5941.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
22
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 22 scope lines.

A2LA certificate 5941.01 · 22 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 1 of 21 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 NAVAIR TECHNOLOGIES INC. 6375 Dixie Road, Unit 7 Mississauga, Ontario, CANADA L5T 2E7 John Raposo Phone: 905 565 1583 ext. 226 CALIBRATION Valid To: September 30, 2026 Certificate Number: 5941.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 8: I. Acoustical Quantities Parameter/Equipment Range CMC2, 6 (±) Comments Sound Pressure – Measuring Equipment (94, 104 ,114) dB Simulation Measure (94, 104 ,114) dB 31.5 Hz 63 Hz to 12.5 kHz 16 kHz 10 Hz to 20 kHz 250 Hz 1000 Hz 0.17 dB 0.16 dB 0.17 dB 0.02 dB 0.08 dB 0.15 dB Sound level calibrator Function generator DMM & simulated microphone Reference microphone
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 2 of 21 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 7 (±) Comments DC Voltage– Generate, Fixed Points 100 mV 1 V 10 V 100 V 1000 V 4.0 µV/V 1.0 µV/V 0.25 µV/V 1.0 µV/V 2.0 µV/V DC voltage reference & reference voltage divider DC voltage reference DC voltage reference & reference voltage divider DC Voltage3– Generate Up to 220 mV 220 mV to 2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 2.9 µV/V + 0.2 µV 2.0 µV/V + 0.4 µV 1.3 µV/V + 1.4 µV 1.2 µV/V + 2.1 µV 2.1 µV/V + 22 µV 2.5 µV/V + 230 µV Multifunction calibrator DC Voltage – Measure, Fixed Points 100 mV 1 V 10 V 100 V 1000 V 4.0 µV/V 1.0 µV/V 0.25 µV/V 1.6 µV/V 2.1 µV/V DC ref, ref V divider, null meter DC ref comparison, null meter DC ref, ref V divider, null meter DC Voltage3 –Measure Up to 100 mV (>0.1 to 1) V (>1 to 10) V (>10 to 100) V (>100 to 1000) V (1 to 10) kV (10 to 70) kV 5.6 µV/V + 0.15 µV 3.6 µV/V + 0.34 µV 3.0 µV/V + 0.8 µV 5.2 µV/V + 35 µV 5.2 µV/V + 150 µV 0.031 % + 0.34 V 0.032 % + 3.4 V Long scale voltmeter HV meter HV meter & HV divider
to 70 kV
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 3 of 21 Parameter/Equipment Range CMC2, 4, 7 (±) Comments DC Current – Measure (0 to 20) pA (20 to 200) pA 200 pA to 2 nA (2 to 20) nA (20 to 200) nA 100 nA to 1 µA (1 to 10) µA (10 to 100) µA (100 to 10 000) µA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 10) A (10 to 100) A 0.58 % + 13 fA 0.58 % + 120 fA 0.23 % + 620 fA 0.23 % + 4.9 pA 0.23 % + 49 pA 6 µA/A + 0.8 pA 4.1 µA/A + 4.5 pA 4.2 µA/A + 59 pA 3.5 µA/A + 650 pA 3.6 µA/A + 3.6 nA 4.3 µA/A + 43 nA 6.9 µA/A + 1 µA 7.1 µA/A + 7.2 µA 31 µA/A + 310 µA Pico ammeter Long scale DMM & standard resistors DC current comparator, standard resistor & voltmeter DC Current – Generate (2 to 20) A (20 to 100) A (100 to 1000) A 0.023 % + 2.5 mA 0.023 % + 15 mA 0.39 % + 0.5 A Transconductance amplifier & calibrator Current coil & calibrator DC Current3 – Generate (0 to 20) pA (20 to 200) pA 200 pA to 2 nA (2 to 20) nA (20 to 200) nA 200 nA to 2 µA (2 to 20) µA (20 to 200) µA (200 to 2000) µA (2 to 20) mA (20 to 200) mA 200 mA to 2A (1 to 3) A (3 to 11) A (11 to 20) A 0.85 % + 1.7 fA 0.057 % + 8.1 fA 0.11 % + 22 fA 0.006 % + 120 fA 0.002 % + 0.4 pA 0.002 % + 3.5 nA 0.002 % + 34 nA 100 µA/A + 3 nA 40 µA/A + 13 nA 40 µA/A + 130 nA 58 µA/A + 1.3µA 40 µA/A + 21 µA 0.039 % + 860 µA 0.05 % + 1.8 mA 0.1 % + 13 mA DC calibrator with precision resistors applied to virtual ground meters Multifunction calibrator
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 4 of 21 Parameter/Frequency Range CMC2, 4, 5, 7 (±) Comments Capacitance – Generate Fixed Points 100/120/1000 Hz 100/120/1000 Hz 10 pF 100 pF 1000 pF 10 nF 100 nF 1 µF 10 µF 10 µF 100 µF 1 mF 10 mF 1F 0.5 µF/F 2.0 µF/F 2.0 µF/F 17 µF/F 38 µF/F 70 µF/F 0.02 % 0.29 % 0.29 % 0.30 % 0.45 % 0.50 % Primary level capacitors Precision bridge & capacitors at 23 °C +/- 0.1 °C Navair 10 µF capacitor 4T capacitance simulator Capacitance3 – Generate 1 kHz 100 Hz 80 Hz 50 Hz 20 Hz DC (0.19 to 3.299 99) nF (1.1 to 3.299 99) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.999) mF (33 to 110) mF 0.39 % + 6.0 pF 0.39 % + 9.3 pF 0.19 % + 12 pF 0.19 % + 72 pF 0.19 % + 110 pF 0.19 % + 360 pF 0.19 % + 1.2 nF 0.19 % + 3.7 nF 0.19 % + 11 nF 0.31 % + 49 nF 0.35 % + 170 nF 0.35 % + 530 nF 0.35 % + 1.7 µF 0.35 % + 5.3 µF 0.37 % + 17 µF 0.59 % + 80 µF 0.8 % + 340 µF Multifunction calibrator
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 5 of 21 Parameter/Frequency Range CMC2, 4, 7 (±) Comments Capacitance– Measure, Fixed Points 1 kHz 10 pF 100 pF 1000 pF 10 nF 100 nF 1 µF 1 µF/F 2.0 µF/F 2.0 µF/F 16 µF/F 36 µF/F 69 µF/F AH 2500A/2700A & reference capacitors Capacitance3– Measure 1 kHz 100 Hz 80 Hz 50 Hz 20 Hz DC (0.19 to 3.299 99) nF (1.1 to 3.299 99) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.999) mF (33 to 110) mF 0.025 % + 0.1 pF 0.016 % + 0.2 pF 0.019 % + 0.6 pF 0.019 % + 2 pF 0.019 % + 6 pF 0.019 % + 20 pF 0.033 % + 0.11 nF 0.033 % + 0.36 nF 0.033 % + 1.1 nF 0.033 % + 3.6 nF 0.04 % + 14 nF 0.04 % + 44 nF 0.07 % + 0.3 µF 0.1 % + 1.1 µF 0.02 % + 0.9 µF 0.02 % + 2.3 µF 0.07 % + 22 µF LCR bridge Charge technique using a DCI source & long scale DMM
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 6 of 21 Parameter/Equipment Range CMC2, 4, 7 (±) Comments Resistance – Measure, Fixed Points 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 µΩ/Ω 5 µΩ/Ω 1 µΩ/Ω 0.5 µΩ/Ω 1.0 µΩ/Ω 1.0 µΩ/Ω 1.0 µΩ/Ω 0.5 µΩ/Ω 1.0 µΩ/Ω 2.0 µΩ/Ω 3.0 µΩ/Ω 8.0 µΩ/Ω 23 µΩ/Ω 83 µΩ/Ω 250 µΩ/Ω 620 µΩ/Ω DCC bridge reference resistors & range extender in oil or air bath Teraohmmeter & air bath Resistance – Measure (0 to 12) Ω (12 to 120) Ω (120 to 1200) Ω (1.2 to 12) kΩ (12 to 120) kΩ 120 kΩ to 1.2 MΩ (1.2 to 12) MΩ (12 to 120) MΩ (20 to 200) MΩ 200 MΩ to 2GΩ (2 to 20) GΩ (20 to 200) GΩ 200 GΩ to 2 TΩ 17 µΩ/Ω + 0.042 mΩ 12 µΩ/Ω + 0.39 mΩ 9.3 µΩ/Ω + 1.4 mΩ 9.3 µΩ/Ω + 14 mΩ 9.3 µΩ/Ω + 110 mΩ 14 µΩ/Ω + 2.7 Ω 50 µΩ/Ω + 120 Ω 580 µΩ/Ω + 7.4 kΩ 93 µΩ/Ω 170 µΩ/Ω 460 µΩ/Ω 690 µΩ/Ω 1200 µΩ/Ω Long scale DMM Teraohmmeter direct measurement
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 7 of 21 Parameter/Equipment Range CMC2, 4, 5, 7 (±) Comments Resistance – Generate, Fixed Points 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 40 µΩ/Ω 30 µΩ/Ω 1.0 µΩ/Ω 0.50 µΩ/Ω 1.0 µΩ/Ω 1.0 µΩ/Ω 1.0 µΩ/Ω 0.50 µΩ/Ω 1.0 µΩ/Ω 2.0 µΩ/Ω 3.0 µΩ/Ω 5.0 µΩ/Ω 30 µΩ/Ω 0.040 % 0.060 % 0.10 % 21 µΩ/Ω 21 µΩ/Ω 9 µΩ/Ω 9 µΩ/Ω 5.7 µΩ/Ω 5.7 µΩ/Ω 5.5 µΩ/Ω 5.5 µΩ/Ω 7.5 µΩ/Ω 7 µΩ/Ω 11 µΩ/Ω 14 µΩ/Ω 31 µΩ/Ω 39 µΩ/Ω 96 µΩ/Ω Standard resistors Multifunction calibrator
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 8 of 21 Parameter/Equipment Range CMC2, 4, 7 (±) Comments Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33to 110) Ω (110 to 330) Ω 330 Ω to 1.1kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 31 µΩ/Ω + 0.0005 Ω 25 µΩ/Ω + 0.001 Ω 22 µΩ/Ω + 0.0015 Ω 22 µΩ/Ω + 0.0034 Ω 22 µΩ/Ω + 0.0082 Ω 22 µΩ/Ω + 0.034 Ω 22 µΩ/Ω + 0.082 Ω 22 µΩ/Ω + 0.34 Ω 22 µΩ/Ω + 0.82 Ω 22 µΩ/Ω + 4 Ω 25 µΩ/Ω + 10 Ω 47 µΩ/Ω + 66 Ω 100 µΩ/Ω + 360 Ω 110 µΩ/Ω + 3.4 kΩ 390 µΩ/Ω + 14 kΩ 2000 µΩ/Ω + 0.31 MΩ 1.2 % + 0.87 MΩ Multifunction calibrator
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 9 of 21 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Voltage3 – Generate (1 to 2.2) mV (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (500 to 1000) kHz 10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (500 to 1000) kHz 10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (500 to 1000) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (500 to 1000) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (500 to 1000) kHz 240 µV/V + 4 µV 91 µV/V + 4 µV 81 µV/V + 4 µV 200 µV/V + 4 µV 500 µV/V + 5.1 µV 1100 µV/V + 10 µV 1400 µV/V + 20 µV 2700 µV/V + 20 µV 240 µV/V + 4.5 µV 91 µV/V + 4.2 µV 81 µV/V + 4.2 µV 200 µV/V + 4.4 µV 500 µV/V + 6.1 µV 1100 µV/V + 12 µV 1400 µV/V + 23 µV 2700 µV/V + 26 µV 240 µV/V + 17 µV 90 µV/V + 9 µV 58 µV/V + 8.3 µV 120 µV/V + 9.6 µV 310 µV/V + 24 µV 66 µV/V + 34 µV 1400 µV/V + 56 µV 2700 µV/V + 100 µV 240 µV/V + 140 µV 90 µV/V + 15 µV 43 µV/V + 8.0 µV 67 µV/V + 10 µV 86 µV/V + 30 µV 340 µV/V + 80 µV 1000 µV/V + 200 µV 1700 µV/V + 300 µV 240 µV/V + 400 µV 90 µV/V + 150 µV 42 µV/V + 50 µV 67 µV/V + 100 µV 84 µV/V + 200 µV 260 µV/V + 600µV 1000 µV/V + 2000 µV 1500 µV/V + 3200 µV Multifunction calibrator
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 10 of 21 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Voltage3 – Generate (cont) (2.2 to 22) V (22 to 220) V (220 to 1100) V (220 to 750) V (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (500 to 1000) kHz (0.04 to 1) kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz (0.4 to 1) kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 240 µV/V + 400 µV 90 µV/V + 150 µV 42 µV/V + 50 µV 67 µV/V + 100 µV 84 µV/V + 200 µV 255 µV/V + 600 µV 1000 µV/V + 2000 µV 1500 µV/V + 3200 µV 80 µV/V + 2.6 mV 150 µV/V + 5.5 mV 900 µV/V + 34 mV 4400 µV/V + 130 mV 8000 µV/V + 240 mV 91 µV/V + 24 mV 170 µV/V + 42 mV 600 µV/V + 140 mV 600 µV/V + 140 mV 2300 µV/V + 550 mV Multifunction calibrator
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 11 of 21 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Current – Measure 2 mA 20 mA 200 mA 2 A 10 A 20A 2 mA 20 mA 200 mA 2 A 10 A 20A 2 mA 20 mA 200 mA 2 A 10 A 20A 2 mA 20 mA 200 mA 2 A 10 A 20 A 2 mA 20 mA 200 mA 2 A 10 A 20 A 40 Hz 500 Hz 1 kHz 5 kHz 10 kHz 35 µA/A 29 µA/A 27 µA/A 29 µA/A 38 µA/A 43 µA/A 35 µA/A 25 µA/A 23 µA/A 25 µA/A 36 µA/A 40 µA/A 35 µA/A 25 µA/A 23 µA/A 25 µA/A 36 µA/A 40 µA/A 35 µA/A 27 µA/A 25 µA/A 27 µA/A 41 µA/A 46 µA/A 35 µA/A 32 µA/A 27 µA/A 29 µA/A 70 µA/A 73 µA/A ACV measurement standard & AC shunts
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 12 of 21 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Current – Measure (cont) (10 to 100) µA (100 to 1000) µA (1 to 10) mA (10 to 100) mA (100 to 1000) mA (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz 0.17 % + 0.032 µA 0.069 % + 0.022 µA 0.069 % + 0.022 µA 0.069 % + 0.022 µA 0.17 % + 0.27 µA 0.069 % + 0.17 µA 0.035 % + 0.14 µA 0.069 % + 0.17 µA 0.17 % + 2.7 µA 0.069 % + 1.7 µA 0.035 % + 1.4 µA 0.069 % + 1.7 µA 0.17 % + 27 µA 0.069 % + 17 µA 0.035 % + 14 µA 0.069 % + 17 µA 0.19 % + 290 µA 0.092 % + 190 µA 0.12 % + 220 µA 0.35 % + 450 µA Long scale DMM
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 13 of 21 Parameter/Equipment Range CMC2, 7 (±) Comments Electrical Simulation of Thermocouple Temperature Indicators3– Type E Type J Type K Type N Type R Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.35 °C 0.16 °C 0.15 °C 0.16 °C 0.16 °C 0.21 °C 0.16 °C 0.15 °C 0.16 °C 0.26 °C 0.25 °C 0.17 °C 0.16 °C 0.21 °C 0.34 °C 0.29 °C 0.19 °C 0.17 °C 0.17 °C 0.21 °C 0.40 °C 0.26 °C 0.25 °C 0.29 °C 0.33 °C 0.27 °C 0.27 °C 0.33 °C 0.44 °C 0.20 °C 0.16 °C 0.09 °C Multifunction calibrator
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 14 of 21 Parameter/Equipment Range CMC2, 7 (±) Comments Electrical Simulation of RTD Temperature Indicators3 – PT 385 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.035 °C 0.035 °C 0.048 °C 0.061 °C 0.068 °C 0.081 °C 0.15 °C Multifunction calibrator Signal Conditioner Amplifiers 10 Hz to 10 kHz Charge Voltage 0.05 % 0.02 % Function generator DMM & capacitor Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Voltage – Measure (0 to 2.2) mV (2.2 to 7) mV (7 to 22) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.17 % + 1 µV 0.074 % + 1 µV 0.042 % + 1 µV 0.082 % + 1 µV 0.12 % + 1.3 µV 0.23 % + 2.1 µV 0.26 % + 4.1 µV 0.50 % + 4.1 µV 0.086 % + 1 µV 0.037 % + 1 µV 0.021 % + 1 µV 0.041 % + 1 µV 0.061 % + 1.3 µV 0.12 % + 2.1 µV 0.14 % + 4.1 µV 0.36 % + 4.3 µV 0.030 % + 1 µV 0.019 % + 1 µV 0.011 % + 1 µV 0.021 % + 1 µV 0.031 % + 1.3 µV 0.82 % + 2.2 µV 0.10 % + 4.2 µV 0.26 % + 4.6 µV AC measurement standard
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 15 of 21 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Voltage – Measure (cont) (22 to 70) mV (70 to 220) mV (220 to 700) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.024 % + 1 µV 0.013 % + 1 µV 0.007 % + 1 µV 0.013 % + 1.1 µV 0.026 % + 1.4 µV 0.053 % + 2.4 µV 0.068 % + 4.5 µV 0.13 % + 4.9 µV 0.021 % + 1.1 µV 0.0089 % + 1 µV 0.0044 % + 1 µV 0.0074 % + 1.2 µV 0.016 % + 1.6 µV 0.028 % + 2.6 µV 0.040 % + 4.9 µV 0.12 % + 6.7 µV 0.021 % + 2.1 µV 0.0078 % + 1.2 µV 0.0038 % + 1 µV 0.0056 % + 1.4 µV 0.0084 % + 18 µV 0.021 % + 3.5 µV 0.034 % + 6.4 µV 0.12 % + 12 µV AC measurement standard
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 16 of 21 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Voltage – Measure (cont) (0.7 to 2.2) V (2.2 to 7) V (7 to 22) V (22 to 70) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.020 % + 4.4 µV 0.0066 % + 1.5 µV 0.0024 % + 1 µV 0.0046 % + 1.1 µV 0.0071 % + 1.7 µV 0.016 % + 4.4 µV 0.026 % + 6.8 µV 0.090 % + 27 µV 0.020 % + 1.4 µV 0.0070 % + 1 µV 0.0024 % + 1 µV 0.0046 % + 1 µV 0.0071 % + 1 µV 0.016 % + 1.5 µV 0.026 % + 3.3 µV 0.090 % + 11 µV 0.022 % + 4.9 µV 0.0081 % + 1.8 µV 0.0037 % + 1 µV 0.0057 % + 1.3 µV 0.0087 % + 1.9 µV 0.022 % + 4.9 µV 0.047 % + 10 µV 0.15 % + 34 µV 0.022 % + 16 µV 0.0082 % + 5.8 µV 0.0044 % + 3.1µV 0.0066 % + 4.6 µV 0.011 % + 7.8 µV 0.022 % + 16 µV 0.051 % + 36 µV 0.15 % + 110 µV AC measurement standard
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 17 of 21 Parameter/Range Frequency CMC2, 4, 5, 7 (±) Comments AC Voltage – Measure (cont) (70 to 220) V (220 to 700) V (700 to 1000) V (1 to 10) kV (10 to 50) kV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 60 Hz 0.022 % + 49 µV 0.0082 % + 18 µV 0.0043 % + 10 µV 0.0080 % + 18 µV 0.011 % + 25 µV 0.026 % + 58 µV 0.070 % + 160 µV 0.022 % + 160 µV 0.017 % + 82 µV 0.0051 % + 36 µV 0.015 % + 110 µV 0.085 % + 600 µV 0.022 % + 220 µV 0.012 % + 120 µV 0.0048 % + 50 µV 0.015 % + 150 µV 0.085 % + 850 µV 0.08 % + 1.4 V 0.09 % + 6.6 V AC measurement standard HV voltmeter & HV probe AC Current – Generate 300 A 600 A 1000A 300 A 600 A 1000A 50/60 Hz 50/60 Hz 50/60 Hz 400 Hz 400 Hz 400 Hz 0.36 % 0.35 % 0.36 % 0.84 % 0.83 % 0.83 % Current coil & calibrator
18--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 18 of 21 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Current3– Generate (10 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 20.5) A (20 to 100) A (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) Hz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (0.02 to 1) kHz (1 to 5) kHz (5 to 10) kHz (40 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 1000) Hz 0.025 % + 17 nA 0.016 % + 11 nA 0.010 % + 9.3 nA 0.028 % + 13 nA 0.11 % + 68 nA 0.025 % + 96 nA 0.016 % + 71 nA 0.010 % + 59 nA 0.020 % + 160 nA 0.11 % + 890 nA 0.025 % + 960 nA 0.016 % + 710 nA 0.012 % + 280 nA 0.022 % + 500 nA 0.11 % + 7400 nA 0.025 % + 9.6 µA 0.016 % + 7.1 µA 0.010 % + 4.9 µA 0.020 % + 8.0 µA 0.11 % + 34 µA 0.024 % + 89 µA 0.045 % + 180 µA 0.70 % + 1.7 mA 0.046 % + 0.22 mA 0.095 % + 0.48 mA 0.36 % + 1.1 mA 0.12 % + 5.1 mA 0.15 % + 5.2 mA 0.30 % + 5.1 mA 0.15 % + 100 mA Multifunction calibrators & trans conductance amplifiers
10 to 100 A
19--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 19 of 21 Parameter/Equipment Range CMC2, 4, 5, 7 (±) Comments Oscilloscopes3 – DC: 50 Ω 1 MΩ Square Wave: 50 Ω Peak-Peak 1 MΩ Peak-Peak Level Sine Wave – Vpp: 50 kHz Reference Time Marker (1 to 25) mV (25 to 110) mV (0.11 to 2.2) V (2.2 to 6.6) V (1 to 25) mV (25 to 110) mV (0.11 to 2.2) V (2.2 to 11) V (11 to 130) V (1 to 25) mV (25 to 110) mV (0.11 to 2.2) V (2.2 to 6.6) V (1 to 25) mV (25 to 110) mV (0.11 to 2.2) V (2.2 to 11) V (11 to 130) V 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 10 Hz to 10 MHz (10 to 125) MHz (125 to 300) MHz 300 MHz to 1.4 GHz (1.4 to 3) GHz (3 to 4) GHz 5 s to 50 ms (20 to100) ms (50 to 20) ns 10 ns (5 to 2) ns 0.15 % + 40 µV 0.15 % + 40 µV 0.15 % + 40 µV 0.15 % + 40 µV 0.07 % + 40 µV 0.07 % + 40 µV 0.07 % + 40 µV 0.07 % + 40 µV 0.07 % + 40 µV 0.15 % + 40 µV 0.15 % + 40 µV 0.15 % + 40 µV 0.15 % + 40 µV 0.11 % + 40 µV 0.11 % + 40 µV 0.11 % + 40 µV 0.11 % + 40 µV 0.11 % + 40 µV 0.8 % + 100 µV 1.3 % + 100 µV 2.0 % + 100 µV 0.6 % 0.6 % 1.2 % 2.9 % 3.5 % 5.9 % 15 µs/s 3.4 µs/s 3.4 µs/s 3.4 µs/s 3.4 µs/s Multifunction calibrator oscilloscope option RF source Multifunction calibrator with oscilloscope option
to 4 GHz
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 20 of 21 III. Mechanical Parameter/Equipment Range CMC2, 4, 7 (±) Comments Vibration Transducers Sensitivity 5 Hz 10Hz (20 to 100) Hz (100, 159.2) Hz (200 to 920) Hz 1000 Hz (2 to 5) kHz 2.5 % 1.5 % 1.3 % 0.6 % 1.1 % 1.5 % 1.7 % By comparison with reference accelerometer IV. Time & Frequency ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. Parameter/Equipment Range CMC2, 6, 7 (±) Comments Frequency – Measuring Equipment & Measure, Fixed Point 10 MHz 5 x 10-11 Hz/Hz Rubidium frequency standard with GPS Frequency3 – Measure Measuring Equipment 1 Hz to 40 GHz 1 Hz to 50 GHz 1 x 10-9 Hz/Hz + 0.1 mHz 1 x 10-9 Hz/Hz + 1 Hz Frequency counters Frequency synthesizers
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5941.01) 2/26/2025 Page 21 of 21 4 The measurands stated are generated using the indica ted instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measuran d in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, the value is defined as the percentage of reading. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 The contributions from the “best existing device”, such as resolution and repeatability of the unit under calibration, are not included in the CMC uncertainties claim. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
22

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited NAVAIR TECHNOLOGIES INC. Mississauga, ON, CANADA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 26th day of February 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 5941.01 Valid to September 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.