FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Italy

ARS CHEMICA

Via Cesare Battisti 45, 26842, Caselle Landi, Italy

ACCREDIA|02064ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
2
Standards
5
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at ARS CHEMICA?

Claim this profile to keep it accurate.

Register record

ACCREDIARefreshed
02064Active

Accredited standards

5

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN 27888Water quality - Determination of electrical conductivity
As written on the certificate · Line 1 (ACCREDIA 02064)

EN ISO 10523:2012; ISO 10523:2008; UNI EN ISO 10523:2012; EN ISO 11885:2009; ISO 11885:2007; UNI EN ISO 11885:2009; EN 27888:1993; UNI EN 27888:1995; EN ISO 16703:2011; ISO 16703:2004; UNI EN ISO 16703:2011; UNI EN ISO 54321:2021; Reg UE 10/2011 14/01/2011 GU UE L12 15/01/2011 Reg UE 2016/1416 24/08/2016 GU UE L230/22 25/08/2016 Reg UE 2020/1245 02/09/2020 GU UE L288 03/09/2020

ISO 10523Water quality - Determination of pH
As written on the certificate · Line 1 (ACCREDIA 02064)

EN ISO 10523:2012; ISO 10523:2008; UNI EN ISO 10523:2012; EN ISO 11885:2009; ISO 11885:2007; UNI EN ISO 11885:2009; EN 27888:1993; UNI EN 27888:1995; EN ISO 16703:2011; ISO 16703:2004; UNI EN ISO 16703:2011; UNI EN ISO 54321:2021; Reg UE 10/2011 14/01/2011 GU UE L12 15/01/2011 Reg UE 2016/1416 24/08/2016 GU UE L230/22 25/08/2016 Reg UE 2020/1245 02/09/2020 GU UE L288 03/09/2020

ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
As written on the certificate · Line 1 (ACCREDIA 02064)

EN ISO 10523:2012; ISO 10523:2008; UNI EN ISO 10523:2012; EN ISO 11885:2009; ISO 11885:2007; UNI EN ISO 11885:2009; EN 27888:1993; UNI EN 27888:1995; EN ISO 16703:2011; ISO 16703:2004; UNI EN ISO 16703:2011; UNI EN ISO 54321:2021; Reg UE 10/2011 14/01/2011 GU UE L12 15/01/2011 Reg UE 2016/1416 24/08/2016 GU UE L230/22 25/08/2016 Reg UE 2020/1245 02/09/2020 GU UE L288 03/09/2020

ISO 16703Soil quality - Determination of content of hydrocarbon in the range C10 to C40 by gas chromatography
As written on the certificate · Line 1 (ACCREDIA 02064)

EN ISO 10523:2012; ISO 10523:2008; UNI EN ISO 10523:2012; EN ISO 11885:2009; ISO 11885:2007; UNI EN ISO 11885:2009; EN 27888:1993; UNI EN 27888:1995; EN ISO 16703:2011; ISO 16703:2004; UNI EN ISO 16703:2011; UNI EN ISO 54321:2021; Reg UE 10/2011 14/01/2011 GU UE L12 15/01/2011 Reg UE 2016/1416 24/08/2016 GU UE L230/22 25/08/2016 Reg UE 2020/1245 02/09/2020 GU UE L288 03/09/2020

ISO 54321Soil, treated biowaste, sludge and waste - Digestion of aqua regia soluble fractions of elements
As written on the certificate · Line 1 (ACCREDIA 02064)

EN ISO 10523:2012; ISO 10523:2008; UNI EN ISO 10523:2012; EN ISO 11885:2009; ISO 11885:2007; UNI EN ISO 11885:2009; EN 27888:1993; UNI EN 27888:1995; EN ISO 16703:2011; ISO 16703:2004; UNI EN ISO 16703:2011; UNI EN ISO 54321:2021; Reg UE 10/2011 14/01/2011 GU UE L12 15/01/2011 Reg UE 2016/1416 24/08/2016 GU UE L230/22 25/08/2016 Reg UE 2020/1245 02/09/2020 GU UE L288 03/09/2020

Scope as published by ACCREDIA

2 lines
ACCREDIA

ISO/IEC 17025

Active

02064

View scope

Accredited scope, certificate 02064

LineDisciplineMethodMatrixRange
1chemicalEN ISO 10523:2012; ISO 10523:2008; UNI EN ISO 10523:2012; EN ISO 11885:2009; ISO 11885:2007; UNI EN ISO 11885:2009; EN 27888:1993; UNI EN 27888:1995; EN ISO 16703:2011; ISO 16703:2004; UNI EN ISO 16703:2011; UNI EN ISO 54321:2021; Reg UE 10/2011 14/01/2011 GU UE L12 15/01/2011 Reg UE 2016/1416 24/08/2016 GU UE L230/22 25/08/2016 Reg UE 2020/1245 02/09/2020 GU UE L288 03/09/2020Acque destinate al consumo umano/Drinking waters, Acque di balneazione/Bathing waters, Acque di piscina (1)/Swimming pool waters (1), Acque di processo (1)/Process waters (1), Acque di scarico/Waste waters, Acque meteoriche/Rain waters, Acque minerali naturali/Natural mineral waters, Acque sotterranee/Ground waters, Acque superficiali/Surface waters, Eluati da test di cessione (1)/Eluates from leaching test (1), Elutriati (1)/Elutriates (1), Fanghi liquidi/Liquid sludges, Percolati (1)/Leachates (1), Rifiuti liquidi acquosi (1)/Aqueous liquid wastes (1); Acque destinate al consumo umano/Drinking waters, Acque di piscina (1)/Swimming pool waters (1), Acque di processo (1)/Process waters (1), Acque di scarico/Waste waters, Acque grezze/Raw water, Acque meteoriche (1)/Rain water (1), Acque minerali naturali (1)/Natural mineral waters (1), Acque sotterranee/Ground waters, Acque superficiali/Surface waters, Percolati (1)/Leachates (1); Acque destinate al consumo umano/Drinking waters, Acque di piscina/Swimming pool waters, Acque di processo (1)/Process waters (1), Acque di scarico/Waste waters, Acque meteoriche (1)/Rain water (1), Acque minerali naturali/Natural mineral waters, Acque naturali/Natural waters, Eluati da test di cessione (1)/Eluates from leaching test (1), Percolati (1)/Leachates (1), Rifiuti liquidi acquosi (1)/Aqueous liquid wastes (1); Fanghi (1)/Sludges (1), Sedimenti (1)/Sediments (1), Terreni/Soils; Fanghi/Sludges, Rifiuti/Wastes, Sedimenti (1)/Sediments (1), Suoli/Soils; Materiali ed articoli a base di plastica destinati a venire in contatto con gli alimenti/Plastic materials and articles intended to come into contact with foodstuffs; Materiali massivi (>= 0,01% amianto)/Bulk materials (>= 0,01% asbestos), Materiali polverulenti (>= 0,01 asbestos)-
2-
ARS CHEMICA SRL Via Cesare Battisti 45 26842 Caselle Landi LO Legenda/Note Allegato al certificato di accreditamento n. 02064 rev. 1 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 4 Sede A Data: 19/12/2025 pag. 2 di 2 Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not provided for by the method but acceptable Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title, see ACCREDIA General Regulation RG-02. Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the accreditation certificate issued to the laboratory. L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions and interpretations based on the results of the specific marked tests. L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that a suspension of accreditation is active for the specific activity shown next to it.

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Cesare Battisti 45, Caselle Landi, 26842, IT

45.10257, 9.79557

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.