Laquafuer Aguas y Medioambiente
C/ Andalucía, 23, 35600, Puerto del Rosario, Spain
- Accredited standards
- 4
- ENAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ENAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 4 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D1426
ISO 9390Water quality - Determination of borate - Spectrometric method using azomethine-H
ISO 17289Water quality - Determination of dissolved oxygen - Optical sensor method
ISO 23696-1Water quality - Determination of nitrate in water using small-scale sealed tubes - Part 1: Dimethylphenol colour reaction
ISO 9390; SM 3500 Fe; ASTM D1426-15 parte A; ISO 23696-1:2023; UNE-EN-26777; SM 4500-Cl- -B; SM 2130; SM 4500 H; SM 2510
SM 2510; ISO 17289:2014; SM 2550; SM 4500-Cl -G; SM 4500 H
SM 2510; ISO 17289:2014; SM 2550
Read from the scope as published by ENAC. Register refreshed 2026-10-10.
Scope as published by ENAC
5 lines
ISO/IEC 17025
Active1472/LE2691
Accredited scope, certificate 1472/LE2691
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNE-EN ISO/IEC 17025:2017; SM 4500 H; SM 2510 | Aguas de consumo; Aguas continentales; Aguas continentales no tratadas; Aguas residuales; Aguas marinas; Piscinas y aguas de rechazo de desaladoras | - |
| 2 | ISO 9390; SM 3500 Fe; ASTM D1426-15 parte A; ISO 23696-1:2023; UNE-EN-26777; SM 4500-Cl- -B; SM 2130; SM 4500 H; SM 2510 | Aguas continentales; Aguas continentales no tratadas | See scope document |
| 3 | SM 4500 H; SM 2510; SM 2130; SM 4500-Cl -G | Aguas residuales; Aguas marinas; Aguas de consumo; Aguas continentales | See scope document |
| 4 | SM 2510; ISO 17289:2014; SM 2550; SM 4500-Cl -G; SM 4500 H | Aguas continentales; Piscinas y aguas de rechazo de desaladoras; Aguas residuales; Aguas marinas | See scope document |
| 5 | SM 2510; ISO 17289:2014; SM 2550 | Aguas marinas | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ENAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.