Testwave
1461 Greg St, 89431-5914, Sparks, NV, United States
Visit website- Scope lines
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 10 scope lines.
A2LA certificate 4866.01 · 10 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 1 of 9
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
TESTWAVE LLC
1461 Greg Street
Sparks, NV 89431-5915
Rhonda Hendrix Phone: 775 356 8378 ext.277
CALIBRATION
Valid To: October 31, 2027 Certificate Number: 4866.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 6:
I. Dimensional
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Calipers
Up to 12 in
(700 + 0.6R) µin
Gage blocks
Micrometers
Up to 12 in
(12 + 2.8L + 0.6R) µin
Gage blocks
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Voltage – Generate
Up to 320 mV
(0.32 to 3.2) V
(3.2 to 32) V
(32 to 320) V
(320 to 1050) V
0.0070 % + 4.8 µV
0.0070 % + 48 µV
0.0076 % + 480 µV
0.0076 % + 5.2 mV
0.0073 % + 23 mV
Multifunction
calibrator | to 12 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 2 of 9
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Voltage – Measure
High Voltage:
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1000 to 2000) V
(2000 to 4000) V
(4000 to 6000) V
(6000 to 7000) V
(7000 to 9000) V
8 µV/V + 0.3 µV
7 µV/V + 0.3 µV
7 µV/V + 0.5 µV
9 µV/V + 30 µV
10 µV/V + 100 µV
1.0 V
2.0 V
3.0 V
3.5 V
8.3 V
Precision multimeter
Precision high
voltage meter w/
probe
DC Current – Generate
Up to 320 µA
(0.19 to 3.2 ) mA
(3.2 to 32) mA
(32 to 320) mA
(0.32 to 3.2) A
(3.2 to 10.5) A
0.016 % + 13 nA
0.016 % + 96 nA
0.016 % + 1.1 µA
0.019 % + 11 µA
0.071 % + 140 µA
0.078 % + 1.1 mA
Multifunction
calibrator
DC Current – Measure
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
31 µA/A + 800 pA
27 µA/A + 5 nA
29 µA/A + 50 nA
46 µA/A + 500 nA
130 µA/A + 10 µA
Precision multimeter | to 9000 V |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 3 of 9
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
Up to 320 mV
320 mV to 3.2 V
(3.2 to 32) V
(32 to 105) V
(105 to 320) V
(320 to 750) V
10 Hz to 3 kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
10 Hz to 3 kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
10 Hz to 3 kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
10 Hz to 3 kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
(40 to 100) Hz
100 Hz to 1 kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 20) kHz
(10 to 20) kHz
(40 to 100) Hz
100 Hz to 1 kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 20) kHz
(10 to 20) kHz
0.05 % output + 22 µV
0.05 % output + 30 µV
0.07 % output + 55 µV
0.10 % output + 120 µV
0.23 % output + 300 µV
0.05 % output + 230 µV
0.05 % output + 300 µV
0.07 % output + 600 µV
0.10 % output + 1.2 mV
0.23 % output + 3.0 mV
0.05 % output + 2.2 mV
0.07 % output + 3.0 mV
0.09 % output + 5.5 mV
0.17 % output + 11 mV
0.40 % output + 37 mV
0.05 % output + 7.3 mV
0.07 % output + 10 mV
0.09 % output + 18 mV
0.17 % output + 36 mV
0.40 % output + 130 mV
0.06 % output + 22 mV
0.06 % output + 22 mV
0.09 % output + 22 mV
0.09 % output + 37 mV
0.14 % output + 55 mV
0.17 % output + 74 mV
0.06 % output + 73 mV
0.06 % output + 73 mV
0.09 % output + 73 mV
0.09 % output + 130 mV
0.14 % output + 190 mV
0.17 % output + 250 mV
Multifunction
calibrator | to 750 V |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 4 of 9
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Measure
(1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
0.03 % output + 3 µV
0.02 % output + 1.1 µV
0.03 % output + 1.1 µV
0.09 % output + 1.1 µV
0.09 % output + 1.1 µV
4.1 % output + 2 µV
0.011 % output + 4 µV
0.011 % output + 2 µV
0.016 % output + 2 µV
0.05 % output + 2 µV
0.09 % output + 2 µV
0.31 % output + 10 µV
0.008 % output + 0.4 mV
0.008 % output + 0.2 mV
0.016 % output + 0.2 mV
0.03 % output + 0.2 mV
0.08 % output + 0.2 mV
0.3 % output + 1 mV
1.0 % output + 1 mV
0.008 % output + 0.4 mV
0.008 % output + 0.2 mV
0.016 % output + 0.2 mV
0.03 % output + 0.2 mV
0.08 % output + 0.2 mV
0.3 % output + 1 mV
1.0 % output + 1 mV
0.02 % output + 4 mV
0.02 % output + 2 mV
0.02 % output + 2 mV
0.036 % output + 2 mV
0.12 % output + 10 mV
0.04 % output + 40 mV
0.04 % output + 20 mV
Precision multimeter | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 5 of 9
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Measure
(cont.)
High Voltage:
(1000 to 1000) V
(1000 to 2000) V
(2000 to 3000) V
(3000 to 4000) V
(4000 to 5000) V
(5000 to 6000) V
(6000 to 7000) V
(7000 to 8000) V
(8000 to 9000) V
(50 to 60) Hz
(60) Hz
(60) Hz
(60) Hz
(60) Hz
(60) Hz
(60) Hz
(60) Hz
(60) Hz
3.6 V
4.8 V
6.3 V
7.9 V
9.3 V
11 V
13 V
14 V
16 V
Precision high
voltage meter w/
probe
AC Current – Generate
Up to 320 µA
320 µA to 3.2 mA
(3.2 to 32) mA
(32 to 320) mA
(0.32 to 3.2) A
(3.2 to 10.5) A
10 Hz to 3 kHz
(3 to 10) kHz
(10 to 20) kHz
(20 to 30) kHz
10 Hz to 3 kHz
(3 to 10) kHz
(10 to 20) kHz
(20 to 30) kHz
10 Hz to 3 kHz
(3 to 10) kHz
(10 to 20) kHz
(20 to 30) kHz
10 Hz to 3 kHz
(3 to 10) kHz
(10 to 20) kHz
(20 to 30) kHz
10 Hz to 3 kHz
(3 to 10) kHz
10 Hz to 3 kHz
(3 to 10) kHz
0.14 % output + 350 nA
0.08 % output + 700 nA
0.16 % output + 2.3 µA
0.19 % output + 3.5 µA
0.09 % output + 350 nA
0.08 % output + 700 nA
0.16 % output + 2.3 µA
0.19 % output + 3.5 µA
0.11 % output + 3.7 µA
0.08 % output + 7.4 µA
0.16 % output + 15 µA
0.19 % output + 26 µA
0.12 % output + 37 µA
0.08 % output + 55 µA
0.16 % output + 74 µA
0.19 % output + 120 µA
0.15 % output + 0.56 mA
0.19 % output + 3.0 mA
0.31 % output + 3.5 mA
0.39 % output + 12 mA
Multifunction
calibrator | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 6 of 9
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Measure
(5 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
0.41 % + 30 nA
0.16 % + 30 nA
0.079 % + 30 nA
0.063 % + 30 nA
0.41 % + 0.2 µA
0.16 % + 0.2 µA
0.062 % + 0.2 µA
0.033 % + 0.2 µA
0.41 % + 20 µA
0.16 % + 20 µA
0.063 % + 20 µA
0.033 % + 20 µA
0.41 % + 20 µA
0.16 % + 20 µA
0.062 % + 20 µA
0.033 % + 20 µA
0.41 % + 0.2 mA
0.17 % + 0.2 mA
0.09 % + 0.2 mA
0.11 % + 0.2 mA
Precision multimeter
Resistance – Generate
(0 to 40) Ω
(40 to 400) Ω
400 Ω to 4 kΩ
(4 to 40) kΩ
(40 to 400) kΩ
400 kΩ to 4 MΩ
(4 to 40) MΩ
(40 to 400) MΩ
0.06 % output + 0.01 mΩ
0.02 % output + 0.012 mΩ
0.02 % output + 0.012 mΩ
0.02 % output + 0.016 mΩ
0.02 % output + 0.016 Ω
0.02 % output + 0.16 Ω
0.06 % output + 0.08 kΩ
0.24 % output + 0.78 kΩ
Multifunction
calibrator
Resistance – Measure
(0 to 10) Ω
(10 to 100) Ω
(100 to 1000) Ω
(1 to 10) kΩ
(10 to 100) kΩ
1 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
31 µΩ/Ω + 50 µΩ
23 µΩ/Ω + 500 µΩ
15 µΩ/Ω + 500 µΩ
15 µΩ/Ω + 5 mΩ
15 µΩ/Ω + 50 mΩ
21 µΩ/Ω + 2 Ω
61 µΩ/Ω + 100 Ω
0.056 % + 1 kΩ
Precision multimeter | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 7 of 9
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Electrical Simulation of
RTDs -
Pt 385, 100 Ω
-200 °C
(-200 to -100) °C
(-100 to -40) °C
(-40 to 0) °C
(0 to 100) °C
(100 to 200) °C
(200 to 300) °C
(300 to 400) °C
(400 to 500) °C
0.006 °C
0.018 °C
0.026 °C
0.031 °C
0.044 °C
0.058 °C
0.072 °C
0.087 °C
0.10 °C
Decade box
Electrical Simulation of
Thermocouples –
Type J
Type K
Type T
Type R
-210 °C
(-210 to -30) °C
(-30 to 0) °C
(0 to 100) °C
(100 to 1200) °C
-250 °C
(-250 to -40) °C
(-40 to 0) °C
(0 to 100) °C
(100 to 600) °C
(600 to 1372) °C
-250 °C
(-250 to -40) °C
(-40 to 0) °C
(0 to 100) °C
(100 to 400) °C
0 °C
(0 to 100) °C
(100 to 500) °C
(500 to 1000) °C
(1000 to 1767) °C
0.41 °C
0.29 °C
0.26 °C
0.29 °C
0.34 °C
0.73 °C
0.29 °C
0.28 °C
0.27 °C
0.35 °C
0.45 °C
0.86 °C
0.37 °C
0.26 °C
0.27 °C
0.25 °C
0.77 °C
0.65 °C
0.50 °C
0.50 °C
0.47 °C
Multifunction
calibrator | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 8 of 9
III. Mechanical
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Pressure and Vacuum –
Measure and Measuring
Equipment
(-12.0 to 30) psig
(0 to 600) psig
(0 to 5000) psig
0.015 psig + 0.6R
0.15 psig + 0.6R
1.3 psig + 0.6R
Reference compound
gauge
Scales and Balances3
(1 to 500) mg
>500 mg to 1 g
(>1 to 2) g
(>2 to 220) g
(>220 to 500) g
>500 g to 5 kg
(>5 to 20) kg
(>20 to 25) kg
(>25 to 35) kg
Up to 10 lb
(>10 to 25) lb
(>25 to 50) lb
(>50 to 100) lbs
(>100 to 300) lbs
(>300 to 500) lbs
(>500 to 1000) lbs
0.0022 mg
0.0059 mg
0.0099 mg
0.18 mg + 0.6R
0.31 mg + 0.6R
5 mg + 0.6R
90 mg + 0.6R
100 mg + 0.6R
950 mg + 0.6R
0.0006 lb
0.0021 lb
0.0042 lb
0.0072 lbs + 0.6R
0.020 lbs + 0.6R
0.030 lbs + 0.6R
0.040 lbs + 0.6R
Class E1 weights
Class E2 weights
Class F weights
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Temperature –
Measuring Equipment
3
(-20 to 0) °C
(>0 to 140) °C
(>0 to 300) °C
0.038 °C
0.046 °C
0.41 °C
PRT w/ dry well
_____________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 9 of 9
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMCs, R is the resolution of the unit under test and L is the length in inches.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 10 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.