Registers refreshed 2026-11-20.See refresh dates
United States

Testwave

1461 Greg St, 89431-5914, Sparks, NV, United States

Visit website
A2LA 4866.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
10
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 10 scope lines.

A2LA certificate 4866.01 · 10 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 1 of 9 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 TESTWAVE LLC 1461 Greg Street Sparks, NV 89431-5915 Rhonda Hendrix Phone: 775 356 8378 ext.277 CALIBRATION Valid To: October 31, 2027 Certificate Number: 4866.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Calipers Up to 12 in (700 + 0.6R) µin Gage blocks Micrometers Up to 12 in (12 + 2.8L + 0.6R) µin Gage blocks II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate Up to 320 mV (0.32 to 3.2) V (3.2 to 32) V (32 to 320) V (320 to 1050) V 0.0070 % + 4.8 µV 0.0070 % + 48 µV 0.0076 % + 480 µV 0.0076 % + 5.2 mV 0.0073 % + 23 mV Multifunction calibrator
to 12 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 2 of 9 Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Measure High Voltage: Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1000 to 2000) V (2000 to 4000) V (4000 to 6000) V (6000 to 7000) V (7000 to 9000) V 8 µV/V + 0.3 µV 7 µV/V + 0.3 µV 7 µV/V + 0.5 µV 9 µV/V + 30 µV 10 µV/V + 100 µV 1.0 V 2.0 V 3.0 V 3.5 V 8.3 V Precision multimeter Precision high voltage meter w/ probe DC Current – Generate Up to 320 µA (0.19 to 3.2 ) mA (3.2 to 32) mA (32 to 320) mA (0.32 to 3.2) A (3.2 to 10.5) A 0.016 % + 13 nA 0.016 % + 96 nA 0.016 % + 1.1 µA 0.019 % + 11 µA 0.071 % + 140 µA 0.078 % + 1.1 mA Multifunction calibrator DC Current – Measure (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 31 µA/A + 800 pA 27 µA/A + 5 nA 29 µA/A + 50 nA 46 µA/A + 500 nA 130 µA/A + 10 µA Precision multimeter
to 9000 V
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 3 of 9 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate Up to 320 mV 320 mV to 3.2 V (3.2 to 32) V (32 to 105) V (105 to 320) V (320 to 750) V 10 Hz to 3 kHz (3 to 10) kHz (10 to 30) kHz (30 to 50) kHz (50 to 100) kHz 10 Hz to 3 kHz (3 to 10) kHz (10 to 30) kHz (30 to 50) kHz (50 to 100) kHz 10 Hz to 3 kHz (3 to 10) kHz (10 to 30) kHz (30 to 50) kHz (50 to 100) kHz 10 Hz to 3 kHz (3 to 10) kHz (10 to 30) kHz (30 to 50) kHz (50 to 100) kHz (40 to 100) Hz 100 Hz to 1 kHz (1 to 3) kHz (3 to 10) kHz (10 to 20) kHz (10 to 20) kHz (40 to 100) Hz 100 Hz to 1 kHz (1 to 3) kHz (3 to 10) kHz (10 to 20) kHz (10 to 20) kHz 0.05 % output + 22 µV 0.05 % output + 30 µV 0.07 % output + 55 µV 0.10 % output + 120 µV 0.23 % output + 300 µV 0.05 % output + 230 µV 0.05 % output + 300 µV 0.07 % output + 600 µV 0.10 % output + 1.2 mV 0.23 % output + 3.0 mV 0.05 % output + 2.2 mV 0.07 % output + 3.0 mV 0.09 % output + 5.5 mV 0.17 % output + 11 mV 0.40 % output + 37 mV 0.05 % output + 7.3 mV 0.07 % output + 10 mV 0.09 % output + 18 mV 0.17 % output + 36 mV 0.40 % output + 130 mV 0.06 % output + 22 mV 0.06 % output + 22 mV 0.09 % output + 22 mV 0.09 % output + 37 mV 0.14 % output + 55 mV 0.17 % output + 74 mV 0.06 % output + 73 mV 0.06 % output + 73 mV 0.09 % output + 73 mV 0.09 % output + 130 mV 0.14 % output + 190 mV 0.17 % output + 250 mV Multifunction calibrator
to 750 V
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 4 of 9 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure (1 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (1 to 40) Hz 40 Hz to 1 kHz 0.03 % output + 3 µV 0.02 % output + 1.1 µV 0.03 % output + 1.1 µV 0.09 % output + 1.1 µV 0.09 % output + 1.1 µV 4.1 % output + 2 µV 0.011 % output + 4 µV 0.011 % output + 2 µV 0.016 % output + 2 µV 0.05 % output + 2 µV 0.09 % output + 2 µV 0.31 % output + 10 µV 0.008 % output + 0.4 mV 0.008 % output + 0.2 mV 0.016 % output + 0.2 mV 0.03 % output + 0.2 mV 0.08 % output + 0.2 mV 0.3 % output + 1 mV 1.0 % output + 1 mV 0.008 % output + 0.4 mV 0.008 % output + 0.2 mV 0.016 % output + 0.2 mV 0.03 % output + 0.2 mV 0.08 % output + 0.2 mV 0.3 % output + 1 mV 1.0 % output + 1 mV 0.02 % output + 4 mV 0.02 % output + 2 mV 0.02 % output + 2 mV 0.036 % output + 2 mV 0.12 % output + 10 mV 0.04 % output + 40 mV 0.04 % output + 20 mV Precision multimeter
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 5 of 9 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure (cont.) High Voltage: (1000 to 1000) V (1000 to 2000) V (2000 to 3000) V (3000 to 4000) V (4000 to 5000) V (5000 to 6000) V (6000 to 7000) V (7000 to 8000) V (8000 to 9000) V (50 to 60) Hz (60) Hz (60) Hz (60) Hz (60) Hz (60) Hz (60) Hz (60) Hz (60) Hz 3.6 V 4.8 V 6.3 V 7.9 V 9.3 V 11 V 13 V 14 V 16 V Precision high voltage meter w/ probe AC Current – Generate Up to 320 µA 320 µA to 3.2 mA (3.2 to 32) mA (32 to 320) mA (0.32 to 3.2) A (3.2 to 10.5) A 10 Hz to 3 kHz (3 to 10) kHz (10 to 20) kHz (20 to 30) kHz 10 Hz to 3 kHz (3 to 10) kHz (10 to 20) kHz (20 to 30) kHz 10 Hz to 3 kHz (3 to 10) kHz (10 to 20) kHz (20 to 30) kHz 10 Hz to 3 kHz (3 to 10) kHz (10 to 20) kHz (20 to 30) kHz 10 Hz to 3 kHz (3 to 10) kHz 10 Hz to 3 kHz (3 to 10) kHz 0.14 % output + 350 nA 0.08 % output + 700 nA 0.16 % output + 2.3 µA 0.19 % output + 3.5 µA 0.09 % output + 350 nA 0.08 % output + 700 nA 0.16 % output + 2.3 µA 0.19 % output + 3.5 µA 0.11 % output + 3.7 µA 0.08 % output + 7.4 µA 0.16 % output + 15 µA 0.19 % output + 26 µA 0.12 % output + 37 µA 0.08 % output + 55 µA 0.16 % output + 74 µA 0.19 % output + 120 µA 0.15 % output + 0.56 mA 0.19 % output + 3.0 mA 0.31 % output + 3.5 mA 0.39 % output + 12 mA Multifunction calibrator
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 6 of 9 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure (5 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz 0.41 % + 30 nA 0.16 % + 30 nA 0.079 % + 30 nA 0.063 % + 30 nA 0.41 % + 0.2 µA 0.16 % + 0.2 µA 0.062 % + 0.2 µA 0.033 % + 0.2 µA 0.41 % + 20 µA 0.16 % + 20 µA 0.063 % + 20 µA 0.033 % + 20 µA 0.41 % + 20 µA 0.16 % + 20 µA 0.062 % + 20 µA 0.033 % + 20 µA 0.41 % + 0.2 mA 0.17 % + 0.2 mA 0.09 % + 0.2 mA 0.11 % + 0.2 mA Precision multimeter Resistance – Generate (0 to 40) Ω (40 to 400) Ω 400 Ω to 4 kΩ (4 to 40) kΩ (40 to 400) kΩ 400 kΩ to 4 MΩ (4 to 40) MΩ (40 to 400) MΩ 0.06 % output + 0.01 mΩ 0.02 % output + 0.012 mΩ 0.02 % output + 0.012 mΩ 0.02 % output + 0.016 mΩ 0.02 % output + 0.016 Ω 0.02 % output + 0.16 Ω 0.06 % output + 0.08 kΩ 0.24 % output + 0.78 kΩ Multifunction calibrator Resistance – Measure (0 to 10) Ω (10 to 100) Ω (100 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ 1 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 31 µΩ/Ω + 50 µΩ 23 µΩ/Ω + 500 µΩ 15 µΩ/Ω + 500 µΩ 15 µΩ/Ω + 5 mΩ 15 µΩ/Ω + 50 mΩ 21 µΩ/Ω + 2 Ω 61 µΩ/Ω + 100 Ω 0.056 % + 1 kΩ Precision multimeter
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 7 of 9 Parameter/Equipment Range CMC2, 5 (±) Comments Electrical Simulation of RTDs - Pt 385, 100 Ω -200 °C (-200 to -100) °C (-100 to -40) °C (-40 to 0) °C (0 to 100) °C (100 to 200) °C (200 to 300) °C (300 to 400) °C (400 to 500) °C 0.006 °C 0.018 °C 0.026 °C 0.031 °C 0.044 °C 0.058 °C 0.072 °C 0.087 °C 0.10 °C Decade box Electrical Simulation of Thermocouples – Type J Type K Type T Type R -210 °C (-210 to -30) °C (-30 to 0) °C (0 to 100) °C (100 to 1200) °C -250 °C (-250 to -40) °C (-40 to 0) °C (0 to 100) °C (100 to 600) °C (600 to 1372) °C -250 °C (-250 to -40) °C (-40 to 0) °C (0 to 100) °C (100 to 400) °C 0 °C (0 to 100) °C (100 to 500) °C (500 to 1000) °C (1000 to 1767) °C 0.41 °C 0.29 °C 0.26 °C 0.29 °C 0.34 °C 0.73 °C 0.29 °C 0.28 °C 0.27 °C 0.35 °C 0.45 °C 0.86 °C 0.37 °C 0.26 °C 0.27 °C 0.25 °C 0.77 °C 0.65 °C 0.50 °C 0.50 °C 0.47 °C Multifunction calibrator
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 8 of 9 III. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Pressure and Vacuum – Measure and Measuring Equipment (-12.0 to 30) psig (0 to 600) psig (0 to 5000) psig 0.015 psig + 0.6R 0.15 psig + 0.6R 1.3 psig + 0.6R Reference compound gauge Scales and Balances3 (1 to 500) mg >500 mg to 1 g (>1 to 2) g (>2 to 220) g (>220 to 500) g >500 g to 5 kg (>5 to 20) kg (>20 to 25) kg (>25 to 35) kg Up to 10 lb (>10 to 25) lb (>25 to 50) lb (>50 to 100) lbs (>100 to 300) lbs (>300 to 500) lbs (>500 to 1000) lbs 0.0022 mg 0.0059 mg 0.0099 mg 0.18 mg + 0.6R 0.31 mg + 0.6R 5 mg + 0.6R 90 mg + 0.6R 100 mg + 0.6R 950 mg + 0.6R 0.0006 lb 0.0021 lb 0.0042 lb 0.0072 lbs + 0.6R 0.020 lbs + 0.6R 0.030 lbs + 0.6R 0.040 lbs + 0.6R Class E1 weights Class E2 weights Class F weights III. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Temperature – Measuring Equipment 3 (-20 to 0) °C (>0 to 140) °C (>0 to 300) °C 0.038 °C 0.046 °C 0.41 °C PRT w/ dry well _____________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4866.01) Revised 1/19/2026 Page 9 of 9 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMCs, R is the resolution of the unit under test and L is the length in inches. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
10ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1461 Greg St, Sparks, NV, 89431-5914, US

39.54047, -119.74872

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.