TUV Rheinland/CCIC (Ningbo) Co.,
EMC Lab, 1st Floor, Building 11, Scholar Innovation Park, Ningbo, 315200, People's Republic of China, Ningbo, China
Visit websiteNo active accreditation in the register.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Withdrawn4902.01
Accredited scope, certificate 4902.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | FCC 47, CFR Part 15, Subpart B (using ANSI C63.4:2014); FCC 47, CFR Part 18 (using MP-5:1986); AS/NZS CISPR 15; CISPR 11; CISPR 12; CISPR 14-1; AS/NZS CISPR 14.1; CISPR 15; CISPR 22; CISPR 32; AS/NZS CISPR 32; EN 55011; EN 55012; EN 55014-1; EN 55015; EN 55032; GB 14023; GB 4343.1; GB 4824; GB/T 9254.1; GB/T 9254.2; ICES-001; ICES-002; ICES-003; ICES-005; J55014-1; J55015; J55011; J55032; AS/NZS 61000.3.2; EN 61000-3-2; GB 17625.1; IEC 61000-3-2; EN 61000-3-11; AS/NZS 61000.3.3; EN 61000-3-3; GB 17625.2; IEC 61000-3-11; IEC 61000-3-3 | - | to 40 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4902.01) 07/17/2024 Page 2 of 3
Immunity
Electrostatic Discharge EN 61000-4-2; IEC 61000-4-2; GB/T 17626.2
Radiated Immunity EN 61000-4-3; IEC 61000-4-3; GB/T 17626.3
Electrical Fast Transient/Burst IEC 61000-4-4; EN 61000-4-4; GB/T 17626.4
Surge IEC 61000-4-5; EN 61000-4-5; GB/T 17626.5
Conducted GB/T 17626.6; IEC 61000-4-6; EN 61000-4-6
Power Frequency Magnetic Field GB/T 17626.8; IEC 61000-4-8; EN 61000-4-8
Voltage Dips, Short Interruptions, and
Voltage Variations
EN 61000-4-11; GB/T 17626.11; IEC 61000-4-11
Radio
United States (FCC)
Canada (ISED)
(To 40 GHz)
FCC 47, CFR Part 15, Subpart C (using ANSI C63.10:2020);
FCC 47, CFR Part 15, Subpart E (using ANSI C63.10:2020);
RSS-210; RSS-216; RSS-247; RSS-248 ;RSS-310;
RSS-GEN;
RF Exposure RSS-102 Measurement (RF Exposure);
KDB 447498, KDB 680106;
EN 62311; IEC 62311; EN 50663; EN 50665; EN 62479
Generic/Product Specific EMC
Standards
Generic/Product Specific EMC
Standards
Generic/Product Specific EMC
Standards
(Cont.)
ANSI C82.77;
CISPR 14-2; CISPR 24; CISPR 35;
EN 12015; EN 12016; EN 12895; EN 15194; EN 50121-3-2;
EN 50121-4; EN 50121-5; EN 50155; EN 50270;
EN 55014-2; EN 55024; EN 55035; EN 60601-1-2;
EN 60945; EN 60974-10; EN 61000-6-1; EN 61000-6-2;
EN 61000-6-3; EN 61000-6-4; EN 61204-3; EN 61326-1;
EN 61326-2-1; EN 61326-2-2; EN 61326-2-3; EN 61326-2-4;
EN 61326-2-5; EN 61326-2-6; EN 61547; EN 62493;
EN ISO 14982; EN 50130-4; EN 61851-21-2
GB 17743; GB 17799.3; GB 17799.4; GB 4343.2;
GB/T 17618; GB/T 17799.1; GB/T 17799.2;
GB/T 18268.1; GB/T 18268.26; GB/T 18595;
GB/T 21398; GB/T 24807; GB/T 24808; GB/T 18487.2
IEC 60571; IEC 60601-1-2; IEC 60945; IEC 60974-10;
IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3;
IEC 61000-6-4; IEC 61204-3; IEC 61326-1;
IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-3;
IEC 61326-2-4; IEC 61326-2-5; IEC 61326-2-6;
IEC 61547; IEC 62236-3-2; IEC 62493; IEC 61851-21-2;
YY9706.102 | ||
| 3 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02) | - | to 40000 MHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
TUV RHEINLAND/CCIC (NINGBO) CO., LTD.
Ningbo, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 17th day of July 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4902.01
Valid to June 30, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
EMC Lab, 1st Floor, Building 11, Scholar Innovation Park, Ningbo, 315200, People's Republic of China, Ningbo, CN
29.87196, 121.54996
Open in MapsLabs with overlapping accredited scope in China
- Guangdong Vanjust Testing Technology Co.,Shantou, Guangdong · ~871 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Guangzhou LCS ComplianceGuangzhou · ~1,111 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Intertek Testing Services Shenzhen Ltd., Guangzhou BranchGuangzhou, Guangdong · ~1,111 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou BranchGuangzhou · ~1,111 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- TUV Rheinland (Guangdong)Guangzhou, Guangdong Province · ~1,114 kmA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.