Y-12 Industrial Hygiene Calibration

301 Bear Creek Road, Bld. 9723-28, MS-8219, PO Box 2009, 37830, Oak Ridge, TN, United States

A2LA 3178.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3178.01 · 4 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3178.01) 11/04/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 Y-12 INDUSTRIAL HYGIENE CALIBRATION LAB 301 Bear Creek Road Bld. 9723-28, MS-8219, PO Box 2009 Oak Ridge TN 37831 Wes Delius Phone: 865 241 1431 CALIBRATION Valid To: August 31, 2027 Certificate Number: 3178.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Chemical Parameter/Equipment Range CMC 2, 3 (±) Comments Gas Detection Equipment Hg Hg Hg CO H 2S LEL O 2 PID CO CO 2 (10 to 400) μg/m³ (0.5 to 999) μg/m³ (0.05 to 500) μg/m³ 100 parts in 10 6 40 parts in 106 50 % LEL 15 % O 2 100 parts in 106 100 parts in 106 1000 parts in 106 15 % 25 % 19 % 5 % 3 % 3 % 3 % 6 % 12 % 20 % Mercury tracker 3000XS with MC-3000 Hg calibrator J405 Jerome mercury J405 Jerome mercury MultiRAE Lite PGM6208 combustible gas detector with calibration gas AQ5000 \ EVM-4 IAQ indoor air quality monitor with calibration gas
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3178.01) 11/04/2025 Page 2 of 3 Parameter/Equipment Range CMC2, 3 (±) Comments Gas Detection Equipment (cont.) – Cl 2 CO HCN NH3 NO NO 2 H2 O2 HCL HF HNO3 Total Organic Relative to Isobutylene 2 parts in 10 6 100 parts in 106 10 parts in 106 25 parts in 106 25 parts in 106 5 parts in 106 0.5 parts in 106 2 parts in 106 2 parts in 106 2 parts in 106 100 parts in 10 6 12 % 12 % 12 % 13 % 12 % 12 % 26 % 17 % 17 % 17 % 3 % Eagle multi-gas detector with calibration gas MiniRAE 2000 PID (photoionization detector) with calibration gas II. Fluid Quantities Parameter/Equipment Range CMC 2, 3, 5 (±) Comments Flow Rate – Measure (0.01 to 30) LPM (l/min) 7.2 % MSA – Zefon: Escort ELF personal sampling pump or high flow sampling pump with BIOS – Defender 510-L,M,H and DCL- L,M,H ___________________________ 1 This laboratory does not offer commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, the value is defined as the percentage of reading. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
0.01 to 30 LPM (l/min)
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3178.01) 11/04/2025 Page 3 of 3 5 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
4ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

301 Bear Creek Road, Bld. 9723-28, MS-8219, PO Box 2009, Oak Ridge, TN, 37830, US

36.01036, -84.26964

Open in Maps