FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Finland

Eurofins Electric & Electronics Finland

Unknown, Finland

FINAS|T290ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
24
Standards
95
Locations
2
One of 2 locations. View the organization

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

No contact information available

Open FINAS register entry
Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Eurofins Electric & Electronics Finland?

Claim this profile to keep it accurate.

Register record

FINASRefreshed
T290Active

Accredited standards

95

Our reading of the FINAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ETSI

ETSI EN 300 113Name not checked yet
As written on the certificate · Line 8 (FINAS T290)

IEC/EN 61326-2-1; IEC/EN 61326-2-2; IEC/EN 61326-2-3; IEC/EN 61326-2-4; IEC/EN 61326-2-5; 3GPP TS 51.010-1; EN 300 113; EN 300 220

ETSI EN 300 220-1Name not checked yet
As written on the certificate · Line 8 (FINAS T290)

IEC/EN 61326-2-1; IEC/EN 61326-2-2; IEC/EN 61326-2-3; IEC/EN 61326-2-4; IEC/EN 61326-2-5; 3GPP TS 51.010-1; EN 300 113; EN 300 220

As written on the certificate · Line 9 (FINAS T290)

EN 300 220-1; EN 300 328; EN 300 330; EN 300 440; EN 303 413; ETSI EN 301 511

ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
As written on the certificate · Line 9 (FINAS T290)

EN 300 220-1; EN 300 328; EN 300 330; EN 300 440; EN 303 413; ETSI EN 301 511

ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
As written on the certificate · Line 9 (FINAS T290)

EN 300 220-1; EN 300 328; EN 300 330; EN 300 440; EN 303 413; ETSI EN 301 511

ETSI EN 300 440Name not checked yet
As written on the certificate · Line 9 (FINAS T290)

EN 300 220-1; EN 300 328; EN 300 330; EN 300 440; EN 303 413; ETSI EN 301 511

ETSI EN 301 489-1Name not checked yet
As written on the certificate · Line 3 (FINAS T290)

EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-6; EN 301 489-17

ETSI EN 301 489-3Name not checked yet
As written on the certificate · Line 3 (FINAS T290)

EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-6; EN 301 489-17

ETSI EN 301 489-5Name not checked yet
As written on the certificate · Line 3 (FINAS T290)

EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-6; EN 301 489-17

ETSI EN 301 489-6Name not checked yet
As written on the certificate · Line 3 (FINAS T290)

EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-6; EN 301 489-17

ETSI EN 301 489-17Name not checked yet
As written on the certificate · Line 3 (FINAS T290)

EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-6; EN 301 489-17

ETSI EN 301 489-19Name not checked yet
As written on the certificate · Line 4 (FINAS T290)

EN 301 489-19; EN 301 489-20; EN 301 489-34; EN 301 489-52; EN 302 208

ETSI EN 301 489-20Name not checked yet
As written on the certificate · Line 4 (FINAS T290)

EN 301 489-19; EN 301 489-20; EN 301 489-34; EN 301 489-52; EN 302 208

ETSI EN 301 489-34Name not checked yet
As written on the certificate · Line 4 (FINAS T290)

EN 301 489-19; EN 301 489-20; EN 301 489-34; EN 301 489-52; EN 302 208

ETSI EN 301 489-52Name not checked yet
As written on the certificate · Line 4 (FINAS T290)

EN 301 489-19; EN 301 489-20; EN 301 489-34; EN 301 489-52; EN 302 208

ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
As written on the certificate · Line 9 (FINAS T290)

EN 300 220-1; EN 300 328; EN 300 330; EN 300 440; EN 303 413; ETSI EN 301 511

ETSI EN 301 893Name not checked yet
As written on the certificate · Line 10 (FINAS T290)

ETSI EN 301 893; ETSI EN 301 908-1; EN 303 687; IEC/EN 60945; IEC 945:1996 ed3; EN 15684; EN 50121-3-2; IEC/EN 60601-1-2

ETSI EN 301 908-1Name not checked yet
As written on the certificate · Line 10 (FINAS T290)

ETSI EN 301 893; ETSI EN 301 908-1; EN 303 687; IEC/EN 60945; IEC 945:1996 ed3; EN 15684; EN 50121-3-2; IEC/EN 60601-1-2

ETSI EN 302 208Name not checked yet
As written on the certificate · Line 4 (FINAS T290)

EN 301 489-19; EN 301 489-20; EN 301 489-34; EN 301 489-52; EN 302 208

ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
As written on the certificate · Line 9 (FINAS T290)

EN 300 220-1; EN 300 328; EN 300 330; EN 300 440; EN 303 413; ETSI EN 301 511

ETSI EN 303 687Name not checked yet
As written on the certificate · Line 10 (FINAS T290)

ETSI EN 301 893; ETSI EN 301 908-1; EN 303 687; IEC/EN 60945; IEC 945:1996 ed3; EN 15684; EN 50121-3-2; IEC/EN 60601-1-2

IEC 61000 series

IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
As written on the certificate · Line 5 (FINAS T290)

IEC/EN 61000-3-2; IEC/EN 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
As written on the certificate · Line 5 (FINAS T290)

IEC/EN 61000-3-2; IEC/EN 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 5 (FINAS T290)

IEC/EN 61000-3-2; IEC/EN 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 5 (FINAS T290)

IEC/EN 61000-3-2; IEC/EN 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 5 (FINAS T290)

IEC/EN 61000-3-2; IEC/EN 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 5 (FINAS T290)

IEC/EN 61000-3-2; IEC/EN 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 5 (FINAS T290)

IEC/EN 61000-3-2; IEC/EN 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
As written on the certificate · Line 6 (FINAS T290)

IEC/EN 61000-4-8; IEC/EN 61000-4-9; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3

IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
As written on the certificate · Line 6 (FINAS T290)

IEC/EN 61000-4-8; IEC/EN 61000-4-9; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
As written on the certificate · Line 6 (FINAS T290)

IEC/EN 61000-4-8; IEC/EN 61000-4-9; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3

IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
As written on the certificate · Line 6 (FINAS T290)

IEC/EN 61000-4-8; IEC/EN 61000-4-9; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3

IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
As written on the certificate · Line 6 (FINAS T290)

IEC/EN 61000-4-8; IEC/EN 61000-4-9; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
As written on the certificate · Line 6 (FINAS T290)

IEC/EN 61000-4-8; IEC/EN 61000-4-9; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
As written on the certificate · Line 6 (FINAS T290)

IEC/EN 61000-4-8; IEC/EN 61000-4-9; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 6 (FINAS T290)

IEC/EN 61000-4-8; IEC/EN 61000-4-9; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
As written on the certificate · Line 7 (FINAS T290)

IEC/EN 61000-6-4; IEC/EN 61000-6-7; CISPR 11 / EN 55011; CISPR 22 / EN 55022; CISPR 24 / EN 55024; CISPR 32 / EN 55032; CISPR35 / EN 55035; IEC/EN 61326-1

IEC 61000-6-7Name not checked yet
As written on the certificate · Line 7 (FINAS T290)

IEC/EN 61000-6-4; IEC/EN 61000-6-7; CISPR 11 / EN 55011; CISPR 22 / EN 55022; CISPR 24 / EN 55024; CISPR 32 / EN 55032; CISPR35 / EN 55035; IEC/EN 61326-1

IEC 60068 series

IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
As written on the certificate · Line 13 (FINAS T290)

RSS-Gen, Issue 5, Amendment 1; RSS-247, Issue 4; ANSI C63.10-2020 + Cor.1-2023; EN 60068-2-1:2007 (IEC 60068-2-1:2007); EN 60068-2-2:2007 (IEC 60068-2-2:2007); EN 60068-2-6:2008 (IEC 60068-2-6:2008); EN 60068-2-11:2021 (IEC 60068-2-11:2021); SFS-EN ISO 9227:2022; EN 60068-2-14:2023

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
As written on the certificate · Line 13 (FINAS T290)

RSS-Gen, Issue 5, Amendment 1; RSS-247, Issue 4; ANSI C63.10-2020 + Cor.1-2023; EN 60068-2-1:2007 (IEC 60068-2-1:2007); EN 60068-2-2:2007 (IEC 60068-2-2:2007); EN 60068-2-6:2008 (IEC 60068-2-6:2008); EN 60068-2-11:2021 (IEC 60068-2-11:2021); SFS-EN ISO 9227:2022; EN 60068-2-14:2023

IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
As written on the certificate · Line 13 (FINAS T290)

RSS-Gen, Issue 5, Amendment 1; RSS-247, Issue 4; ANSI C63.10-2020 + Cor.1-2023; EN 60068-2-1:2007 (IEC 60068-2-1:2007); EN 60068-2-2:2007 (IEC 60068-2-2:2007); EN 60068-2-6:2008 (IEC 60068-2-6:2008); EN 60068-2-11:2021 (IEC 60068-2-11:2021); SFS-EN ISO 9227:2022; EN 60068-2-14:2023

IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
As written on the certificate · Line 13 (FINAS T290)

RSS-Gen, Issue 5, Amendment 1; RSS-247, Issue 4; ANSI C63.10-2020 + Cor.1-2023; EN 60068-2-1:2007 (IEC 60068-2-1:2007); EN 60068-2-2:2007 (IEC 60068-2-2:2007); EN 60068-2-6:2008 (IEC 60068-2-6:2008); EN 60068-2-11:2021 (IEC 60068-2-11:2021); SFS-EN ISO 9227:2022; EN 60068-2-14:2023

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
As written on the certificate · Line 13 (FINAS T290)

RSS-Gen, Issue 5, Amendment 1; RSS-247, Issue 4; ANSI C63.10-2020 + Cor.1-2023; EN 60068-2-1:2007 (IEC 60068-2-1:2007); EN 60068-2-2:2007 (IEC 60068-2-2:2007); EN 60068-2-6:2008 (IEC 60068-2-6:2008); EN 60068-2-11:2021 (IEC 60068-2-11:2021); SFS-EN ISO 9227:2022; EN 60068-2-14:2023

As written on the certificate · Line 14 (FINAS T290)

EN 60068-2-14:2024; EN 60068-2-27:2008; EN 60068-2-30:2005; EN 60068-2-31:2008; EN 60068-2-38:2021; EN 60068-2-52:2018; EN 60068-2-64:2008; EN 60068-2-67:2019; IEC 60068-2-14:2024; IEC 60068-2-27:2008; IEC 60068-2-30:2005; IEC 60068-2-31:2008; IEC 60068-2-38:2021; IEC 60068-2-52:2018; IEC 60068-2-64:2008; IEC 60068-2-67:2019

IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
As written on the certificate · Line 14 (FINAS T290)

EN 60068-2-14:2024; EN 60068-2-27:2008; EN 60068-2-30:2005; EN 60068-2-31:2008; EN 60068-2-38:2021; EN 60068-2-52:2018; EN 60068-2-64:2008; EN 60068-2-67:2019; IEC 60068-2-14:2024; IEC 60068-2-27:2008; IEC 60068-2-30:2005; IEC 60068-2-31:2008; IEC 60068-2-38:2021; IEC 60068-2-52:2018; IEC 60068-2-64:2008; IEC 60068-2-67:2019

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
As written on the certificate · Line 14 (FINAS T290)

EN 60068-2-14:2024; EN 60068-2-27:2008; EN 60068-2-30:2005; EN 60068-2-31:2008; EN 60068-2-38:2021; EN 60068-2-52:2018; EN 60068-2-64:2008; EN 60068-2-67:2019; IEC 60068-2-14:2024; IEC 60068-2-27:2008; IEC 60068-2-30:2005; IEC 60068-2-31:2008; IEC 60068-2-38:2021; IEC 60068-2-52:2018; IEC 60068-2-64:2008; IEC 60068-2-67:2019

IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
As written on the certificate · Line 14 (FINAS T290)

EN 60068-2-14:2024; EN 60068-2-27:2008; EN 60068-2-30:2005; EN 60068-2-31:2008; EN 60068-2-38:2021; EN 60068-2-52:2018; EN 60068-2-64:2008; EN 60068-2-67:2019; IEC 60068-2-14:2024; IEC 60068-2-27:2008; IEC 60068-2-30:2005; IEC 60068-2-31:2008; IEC 60068-2-38:2021; IEC 60068-2-52:2018; IEC 60068-2-64:2008; IEC 60068-2-67:2019

IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
As written on the certificate · Line 14 (FINAS T290)

EN 60068-2-14:2024; EN 60068-2-27:2008; EN 60068-2-30:2005; EN 60068-2-31:2008; EN 60068-2-38:2021; EN 60068-2-52:2018; EN 60068-2-64:2008; EN 60068-2-67:2019; IEC 60068-2-14:2024; IEC 60068-2-27:2008; IEC 60068-2-30:2005; IEC 60068-2-31:2008; IEC 60068-2-38:2021; IEC 60068-2-52:2018; IEC 60068-2-64:2008; IEC 60068-2-67:2019

IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
As written on the certificate · Line 14 (FINAS T290)

EN 60068-2-14:2024; EN 60068-2-27:2008; EN 60068-2-30:2005; EN 60068-2-31:2008; EN 60068-2-38:2021; EN 60068-2-52:2018; EN 60068-2-64:2008; EN 60068-2-67:2019; IEC 60068-2-14:2024; IEC 60068-2-27:2008; IEC 60068-2-30:2005; IEC 60068-2-31:2008; IEC 60068-2-38:2021; IEC 60068-2-52:2018; IEC 60068-2-64:2008; IEC 60068-2-67:2019

IEC 60068-2-55Name not checked yet
As written on the certificate · Line 15 (FINAS T290)

EN 60068-2-78:2012 (IEC 60068-2-78:2012); EN 60529:19889+AMD1:1999+AMD2:2013; EN 60068-2-80:2005 (IEC 60068-2-80:2005); NEMA 250-2014, Type 4:2020; IEC 60068-2-55:2013; ISTA 2A :2011; SFS-EN 62262:2002+AMD1:2021 (IEC 62262:2002)

IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidanceCertificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 14 (FINAS T290)

EN 60068-2-14:2024; EN 60068-2-27:2008; EN 60068-2-30:2005; EN 60068-2-31:2008; EN 60068-2-38:2021; EN 60068-2-52:2018; EN 60068-2-64:2008; EN 60068-2-67:2019; IEC 60068-2-14:2024; IEC 60068-2-27:2008; IEC 60068-2-30:2005; IEC 60068-2-31:2008; IEC 60068-2-38:2021; IEC 60068-2-52:2018; IEC 60068-2-64:2008; IEC 60068-2-67:2019

IEC 60068-2-67Name not checked yet
As written on the certificate · Line 14 (FINAS T290)

EN 60068-2-14:2024; EN 60068-2-27:2008; EN 60068-2-30:2005; EN 60068-2-31:2008; EN 60068-2-38:2021; EN 60068-2-52:2018; EN 60068-2-64:2008; EN 60068-2-67:2019; IEC 60068-2-14:2024; IEC 60068-2-27:2008; IEC 60068-2-30:2005; IEC 60068-2-31:2008; IEC 60068-2-38:2021; IEC 60068-2-52:2018; IEC 60068-2-64:2008; IEC 60068-2-67:2019

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
As written on the certificate · Line 15 (FINAS T290)

EN 60068-2-78:2012 (IEC 60068-2-78:2012); EN 60529:19889+AMD1:1999+AMD2:2013; EN 60068-2-80:2005 (IEC 60068-2-80:2005); NEMA 250-2014, Type 4:2020; IEC 60068-2-55:2013; ISTA 2A :2011; SFS-EN 62262:2002+AMD1:2021 (IEC 62262:2002)

IEC 60068-2-80Environmental testing - Part 2-80: Tests - Test Fi: Vibration - Mixed mode
As written on the certificate · Line 15 (FINAS T290)

EN 60068-2-78:2012 (IEC 60068-2-78:2012); EN 60529:19889+AMD1:1999+AMD2:2013; EN 60068-2-80:2005 (IEC 60068-2-80:2005); NEMA 250-2014, Type 4:2020; IEC 60068-2-55:2013; ISTA 2A :2011; SFS-EN 62262:2002+AMD1:2021 (IEC 62262:2002)

IEC 60079 series

IEC 60079-0Name not checked yet
As written on the certificate · Line 19 (FINAS T290)

IEC/EN 60079-0; IEC/EN 60079-6; IEC/EN 60079-2

IEC 60079-1Name not checked yet
As written on the certificate · Line 20 (FINAS T290)

IEC/EN 60079-5; IEC/EN 60079-1; IEC/EN 60079-7; IEC/EN 60079-11; IEC/EN 60079-15

IEC 60079-2Name not checked yet
As written on the certificate · Line 19 (FINAS T290)

IEC/EN 60079-0; IEC/EN 60079-6; IEC/EN 60079-2

IEC 60079-5Name not checked yet
As written on the certificate · Line 20 (FINAS T290)

IEC/EN 60079-5; IEC/EN 60079-1; IEC/EN 60079-7; IEC/EN 60079-11; IEC/EN 60079-15

IEC 60079-6Name not checked yet
As written on the certificate · Line 19 (FINAS T290)

IEC/EN 60079-0; IEC/EN 60079-6; IEC/EN 60079-2

IEC 60079-7Name not checked yet
As written on the certificate · Line 20 (FINAS T290)

IEC/EN 60079-5; IEC/EN 60079-1; IEC/EN 60079-7; IEC/EN 60079-11; IEC/EN 60079-15

IEC 60079-11Name not checked yet
As written on the certificate · Line 20 (FINAS T290)

IEC/EN 60079-5; IEC/EN 60079-1; IEC/EN 60079-7; IEC/EN 60079-11; IEC/EN 60079-15

IEC 60079-15Name not checked yet
As written on the certificate · Line 20 (FINAS T290)

IEC/EN 60079-5; IEC/EN 60079-1; IEC/EN 60079-7; IEC/EN 60079-11; IEC/EN 60079-15

IEC 60079-18Name not checked yet
As written on the certificate · Line 21 (FINAS T290)

IEC/EN 60079-18; IEC/EN 60079-28; IEC/EN 60079-25; IEC/EN 60079-31

IEC 60079-25Name not checked yet
As written on the certificate · Line 21 (FINAS T290)

IEC/EN 60079-18; IEC/EN 60079-28; IEC/EN 60079-25; IEC/EN 60079-31

IEC 60079-26Name not checked yet
As written on the certificate · Line 22 (FINAS T290)

IEC/EN 60079-26; EN 50303; EN 14986; IEC TS 60079-46:2017

IEC 60079-28Name not checked yet
As written on the certificate · Line 21 (FINAS T290)

IEC/EN 60079-18; IEC/EN 60079-28; IEC/EN 60079-25; IEC/EN 60079-31

IEC 60079-31Name not checked yet
As written on the certificate · Line 21 (FINAS T290)

IEC/EN 60079-18; IEC/EN 60079-28; IEC/EN 60079-25; IEC/EN 60079-31

CISPR

CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 7 (FINAS T290)

IEC/EN 61000-6-4; IEC/EN 61000-6-7; CISPR 11 / EN 55011; CISPR 22 / EN 55022; CISPR 24 / EN 55024; CISPR 32 / EN 55032; CISPR35 / EN 55035; IEC/EN 61326-1

CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurementsCertificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 11 (FINAS T290)

CISPR 16-2-3 / EN 55016-2-3; CISPR 16-2-1 / EN 55016-2-1; ISO 7637-2:2004; CFR 47 Subpart 15 B ANSI C63.4-2014 amended as per ANSI C63.4a-2017; CFR 47 Subpart 18 FCC MP-5:1986-02

CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurementsCertificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 11 (FINAS T290)

CISPR 16-2-3 / EN 55016-2-3; CISPR 16-2-1 / EN 55016-2-1; ISO 7637-2:2004; CFR 47 Subpart 15 B ANSI C63.4-2014 amended as per ANSI C63.4a-2017; CFR 47 Subpart 18 FCC MP-5:1986-02

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55022. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 7 (FINAS T290)

IEC/EN 61000-6-4; IEC/EN 61000-6-7; CISPR 11 / EN 55011; CISPR 22 / EN 55022; CISPR 24 / EN 55024; CISPR 32 / EN 55032; CISPR35 / EN 55035; IEC/EN 61326-1

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurementCertificate says EN 55024. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 7 (FINAS T290)

IEC/EN 61000-6-4; IEC/EN 61000-6-7; CISPR 11 / EN 55011; CISPR 22 / EN 55022; CISPR 24 / EN 55024; CISPR 32 / EN 55032; CISPR35 / EN 55035; IEC/EN 61326-1

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 7 (FINAS T290)

IEC/EN 61000-6-4; IEC/EN 61000-6-7; CISPR 11 / EN 55011; CISPR 22 / EN 55022; CISPR 24 / EN 55024; CISPR 32 / EN 55032; CISPR35 / EN 55035; IEC/EN 61326-1

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsCertificate says EN 55035. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 7 (FINAS T290)

IEC/EN 61000-6-4; IEC/EN 61000-6-7; CISPR 11 / EN 55011; CISPR 22 / EN 55022; CISPR 24 / EN 55024; CISPR 32 / EN 55032; CISPR35 / EN 55035; IEC/EN 61326-1

IEC 61326 series

IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
As written on the certificate · Line 7 (FINAS T290)

IEC/EN 61000-6-4; IEC/EN 61000-6-7; CISPR 11 / EN 55011; CISPR 22 / EN 55022; CISPR 24 / EN 55024; CISPR 32 / EN 55032; CISPR35 / EN 55035; IEC/EN 61326-1

IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
As written on the certificate · Line 8 (FINAS T290)

IEC/EN 61326-2-1; IEC/EN 61326-2-2; IEC/EN 61326-2-3; IEC/EN 61326-2-4; IEC/EN 61326-2-5; 3GPP TS 51.010-1; EN 300 113; EN 300 220

IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
As written on the certificate · Line 8 (FINAS T290)

IEC/EN 61326-2-1; IEC/EN 61326-2-2; IEC/EN 61326-2-3; IEC/EN 61326-2-4; IEC/EN 61326-2-5; 3GPP TS 51.010-1; EN 300 113; EN 300 220

IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
As written on the certificate · Line 8 (FINAS T290)

IEC/EN 61326-2-1; IEC/EN 61326-2-2; IEC/EN 61326-2-3; IEC/EN 61326-2-4; IEC/EN 61326-2-5; 3GPP TS 51.010-1; EN 300 113; EN 300 220

IEC 61326-2-4Name not checked yet
As written on the certificate · Line 8 (FINAS T290)

IEC/EN 61326-2-1; IEC/EN 61326-2-2; IEC/EN 61326-2-3; IEC/EN 61326-2-4; IEC/EN 61326-2-5; 3GPP TS 51.010-1; EN 300 113; EN 300 220

IEC 61326-2-5Name not checked yet
As written on the certificate · Line 8 (FINAS T290)

IEC/EN 61326-2-1; IEC/EN 61326-2-2; IEC/EN 61326-2-3; IEC/EN 61326-2-4; IEC/EN 61326-2-5; 3GPP TS 51.010-1; EN 300 113; EN 300 220

IEC

IEC 60529Degrees of protection provided by enclosures (IP Code)
As written on the certificate · Line 15 (FINAS T290)

EN 60068-2-78:2012 (IEC 60068-2-78:2012); EN 60529:19889+AMD1:1999+AMD2:2013; EN 60068-2-80:2005 (IEC 60068-2-80:2005); NEMA 250-2014, Type 4:2020; IEC 60068-2-55:2013; ISTA 2A :2011; SFS-EN 62262:2002+AMD1:2021 (IEC 62262:2002)

As written on the certificate · Line 18 (FINAS T290)

IEC/EN 62368-3; IEC/EN 60529

IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
As written on the certificate · Line 10 (FINAS T290)

ETSI EN 301 893; ETSI EN 301 908-1; EN 303 687; IEC/EN 60945; IEC 945:1996 ed3; EN 15684; EN 50121-3-2; IEC/EN 60601-1-2

IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test resultsCertificate says IEC 945. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 10 (FINAS T290)

ETSI EN 301 893; ETSI EN 301 908-1; EN 303 687; IEC/EN 60945; IEC 945:1996 ed3; EN 15684; EN 50121-3-2; IEC/EN 60601-1-2

IEC 62262Name not checked yet
As written on the certificate · Line 15 (FINAS T290)

EN 60068-2-78:2012 (IEC 60068-2-78:2012); EN 60529:19889+AMD1:1999+AMD2:2013; EN 60068-2-80:2005 (IEC 60068-2-80:2005); NEMA 250-2014, Type 4:2020; IEC 60068-2-55:2013; ISTA 2A :2011; SFS-EN 62262:2002+AMD1:2021 (IEC 62262:2002)

IEC 62368-3Name not checked yet
As written on the certificate · Line 18 (FINAS T290)

IEC/EN 62368-3; IEC/EN 60529

EN

EN 14986Name not checked yet
As written on the certificate · Line 22 (FINAS T290)

IEC/EN 60079-26; EN 50303; EN 14986; IEC TS 60079-46:2017

EN 15684Name not checked yet
As written on the certificate · Line 10 (FINAS T290)

ETSI EN 301 893; ETSI EN 301 908-1; EN 303 687; IEC/EN 60945; IEC 945:1996 ed3; EN 15684; EN 50121-3-2; IEC/EN 60601-1-2

EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
As written on the certificate · Line 10 (FINAS T290)

ETSI EN 301 893; ETSI EN 301 908-1; EN 303 687; IEC/EN 60945; IEC 945:1996 ed3; EN 15684; EN 50121-3-2; IEC/EN 60601-1-2

EN 50303Name not checked yet
As written on the certificate · Line 22 (FINAS T290)

IEC/EN 60079-26; EN 50303; EN 14986; IEC TS 60079-46:2017

ISO

ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
As written on the certificate · Line 11 (FINAS T290)

CISPR 16-2-3 / EN 55016-2-3; CISPR 16-2-1 / EN 55016-2-1; ISO 7637-2:2004; CFR 47 Subpart 15 B ANSI C63.4-2014 amended as per ANSI C63.4a-2017; CFR 47 Subpart 18 FCC MP-5:1986-02

ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
As written on the certificate · Line 13 (FINAS T290)

RSS-Gen, Issue 5, Amendment 1; RSS-247, Issue 4; ANSI C63.10-2020 + Cor.1-2023; EN 60068-2-1:2007 (IEC 60068-2-1:2007); EN 60068-2-2:2007 (IEC 60068-2-2:2007); EN 60068-2-6:2008 (IEC 60068-2-6:2008); EN 60068-2-11:2021 (IEC 60068-2-11:2021); SFS-EN ISO 9227:2022; EN 60068-2-14:2023

ISO 80079-36Explosive atmospheres - Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements
As written on the certificate · Line 23 (FINAS T290)

EN ISO/IEC 80079-36; EN ISO/IEC 80079-37

ISO 80079-37Explosive atmospheres - Part 37: Non-electrical equipment for explosive atmospheres - Non-electrical type of protection constructional safety ''c'', control of ignition sources ''b'', liquid immersion ''k''
As written on the certificate · Line 23 (FINAS T290)

EN ISO/IEC 80079-36; EN ISO/IEC 80079-37

IEC 61010 series

IEC 61010-2-010Name not checked yet
As written on the certificate · Line 17 (FINAS T290)

IEC/EN/UL/CSAC 22.2/AS 61010-1; EN IEC 61010-2-010 / IEC 61010-2-010; EN IEC 61010-2-081 / IEC 61010-2-081; EN 61010-2-101 / IEC 61010-2-101; IEC/EN/UL/CSAC 22.2/AS/NZ 62368-1

IEC 61010-2-081Name not checked yet
As written on the certificate · Line 17 (FINAS T290)

IEC/EN/UL/CSAC 22.2/AS 61010-1; EN IEC 61010-2-010 / IEC 61010-2-010; EN IEC 61010-2-081 / IEC 61010-2-081; EN 61010-2-101 / IEC 61010-2-101; IEC/EN/UL/CSAC 22.2/AS/NZ 62368-1

IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
As written on the certificate · Line 17 (FINAS T290)

IEC/EN/UL/CSAC 22.2/AS 61010-1; EN IEC 61010-2-010 / IEC 61010-2-010; EN IEC 61010-2-081 / IEC 61010-2-081; EN 61010-2-101 / IEC 61010-2-101; IEC/EN/UL/CSAC 22.2/AS/NZ 62368-1

Other standards

FCC PART 15Radio Frequency Devices
As written on the certificate · Line 11 (FINAS T290)

CISPR 16-2-3 / EN 55016-2-3; CISPR 16-2-1 / EN 55016-2-1; ISO 7637-2:2004; CFR 47 Subpart 15 B ANSI C63.4-2014 amended as per ANSI C63.4a-2017; CFR 47 Subpart 18 FCC MP-5:1986-02

Scope as published by FINAS

24 lines
FINAS

ISO/IEC 17025

Active

T290

View scope

Location

Unknown, FI

62.75546, 29.40410

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the FINAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the FINAS entry linked above.