Registers refreshed 2026-11-20.See refresh dates
United States

Applied Test Systems

Calibration Department, 154 East Brook Lane, 16002, Butler, PA, United States

Visit website
A2LA 2132.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
7
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 7 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM D1598
ASTM D1599
ASTM D6521
ASTM E4
ASTM E83
ASTM E1012
ASTM E2309

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

2132.01

The scope document we hold says it was valid until 2026-02-28. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 2132.01

LineMethodMatrixRange
1ASTM E83; ASTM E2309-; ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 APPLIED TEST SYSTEMS 154-See scope document
2ASTM E4ElectronicSee scope document
3ASTM E4; ASTM D6521; ASTM D1599; ASTM D1598; ASTM E1012-to 300000 lbf
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2132.01) Revised 2/12/2025 Page 4 of 4 IV. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature3 – Measure (-40 to 180) °C (15 to 30) °C (59 to 86) °F 0.037 °C 0.35 °C 0.63 °F Digital monitor w/ platinum RTD Fluke 51 w/ thermocouple _________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve w/in its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This laboratory performs field calibration activities for these parameters. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for othe r possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could re sult in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated, FS is defined as full scale. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
-40 to 180 °C
5ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Calibration Department, 154 East Brook Lane, Butler, PA, 16002, US

40.86047, -79.89705

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.