Applied Test Systems
Calibration Department, 154 East Brook Lane, 16002, Butler, PA, United States
Visit website- Accredited standards
- 7
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 7 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D1598
ASTM D1599
ASTM D6521
ASTM E4
ASTM E83
ASTM E1012
ASTM E2309
ASTM E4; ASTM D6521; ASTM D1599; ASTM D1598; ASTM E1012
ASTM E4
ASTM E83; ASTM E2309-; ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 APPLIED TEST SYSTEMS 154
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active2132.01
The scope document we hold says it was valid until 2026-02-28. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.
Accredited scope, certificate 2132.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM E83; ASTM E2309-; ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 APPLIED TEST SYSTEMS 154 | - | See scope document |
| 2 | ASTM E4 | Electronic | See scope document |
| 3 | ASTM E4; ASTM D6521; ASTM D1599; ASTM D1598; ASTM E1012 | - | to 300000 lbf |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2132.01) Revised 2/12/2025 Page 4 of 4
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature3 – Measure
(-40 to 180) °C
(15 to 30) °C
(59 to 86)
°F
0.037 °C
0.35 °C
0.63 °F
Digital monitor w/
platinum RTD
Fluke 51 w/
thermocouple
_________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve w/in its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This laboratory performs field calibration activities for these parameters. Please note the actual
measurement uncertainties achievable on a customer's site can normally be expected to be larger than the
CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the
place of calibration and for othe r possible adverse effects such as those caused by transportation of the
calibration equipment. The usual allowance for the actual uncertainty introduced by the item being
calibrated, (e.g. resolution) must also be considered and this, on its own, could re sult in the actual
measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated, FS is defined
as full scale.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | -40 to 180 °C |
| 5 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Applied Technical ServicesGreer, SC · ~689 kmA2LAShares 2 accredited methods and materialsASTM E4Electronic
- Applied Technical Services, LLC.Bartlett, TN · ~1,075 kmA2LAShares 2 accredited methods and materialsASTM E4Electronic
- Applied Technical Services , LLC.Sanford, FL · ~1,348 kmA2LAShares 2 accredited methods and materialsASTM E4Electronic
- Cal-Cert CompanyAnaheim Hills, CAA2LAShares 2 accredited methods and materialsASTM E4Electronic
- All American Scales & CalibrationParis, OH · ~107 kmA2LAShares 1 accredited test methodASTM E4
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.