FindTestingLabs
Registers refreshed 2026-10-25.See refresh dates
United States

IIA Lab Services, LLC - Danville

Center for manufacturing advancement - IIA bay 1, Attn: IIA bay 1, 24540, Danville, VA, United States

A2LA 7591.01A2LA 7591.02ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
8
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

In our data, A2LA certificates 7591.01 and 7591.02 carry the same scope document, so its lines are read once.

Only this lab. Searches the 8 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
ASTM E23Standard Test Methods for Notched Bar Impact Testing of Metallic Materials
ASTM E92Standard Test Methods for Vickers Hardness and Knoop Hardness of Metallic Materials
ASTM E340Standard Practice for Macroetching Metals and Alloys
ASTM E407Standard Practice for Microetching Metals and Alloys
ASTM E1245
ASTM F3637

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-10-23.

Scope as published by A2LA

2 lines
A2LA

ISO/IEC 17025

Active

7591.01

The scope document we hold says it is valid until 2028-04-30.

View scope

Accredited scope, certificate 7591.01

LineMethodMatrixRange
1ASTM E92; ASTM E8/E8M; ASTM E407; ASTM E340; ASTM E23/A370; AWS B4.0 Sec. 6; ASTM E3; ASTM E1245; ASTM F3637metals-
2ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

7591.02

Same scope document as certificate 7591.01.

The scope document we hold says it is valid until 2028-04-30.

Location

Center for manufacturing advancement - IIA bay 1, Attn: IIA bay 1, Danville, VA, 24540, US

36.58799, -79.39167

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.