Valley Calibration Services

1780 WHIPPLE RD STE 204, 94587-1954, Union city, CA, United States

Visit website
A2LA 5950.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 5 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E898
ASTM E1154
ISO 6789-1Assembly tools for screws and nuts - Hand torque tools - Part 1: Requirements and methods for design conformance testing and quality conformance testing: minimum requirements for declaration of conformance
ISO 6789-2Assembly tools for screws and nuts - Hand torque tools - Part 2: Requirements for calibration and determination of measurement uncertainty
ISO 8655

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-10-23.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

5950.01

The scope document we hold says it is valid until 2027-02-28.

View scope

Accredited scope, certificate 5950.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; ISO 8655; ASTM E1154; ASTM E898-20; ISO 6789-1; ISO 6789-2-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5950.01) 09/23/2025 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects s uch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1780 WHIPPLE RD STE 204, Union city, CA, 94587-1954, US

37.58726, -122.02157

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.