Registers refreshed 2026-11-20.See refresh dates
United States

Guilford Performance Textiles - Pine Grove

1 Penn Dye Street, 17963, Pine Grove, PA, United States

Visit website
A2LA 1051.03ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
35
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 35 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM18
ASTM D1388
ASTM D1776
ASTM D1777
ASTM D2261
ASTM D2594
ASTM D3512
ASTM D3774
ASTM D3776
ASTM D3882
ASTM D4966
ASTM D5034
ASTM D5035
Show all 18
ASTM D5169
ASTM D5170
ASTM D5587
ASTM D6614
ASTM D6797
ASTM D8007
AATCC10
AATCC 8
AATCC 15
AATCC 22
AATCC 61
AATCC 79
AATCC 81
AATCC 107
AATCC 135
AATCC 163
AATCC 179
ISO 105 series4
ISO 105-C06Textiles - Tests for colour fastness - Part C06: Colour fastness to domestic and commercial laundering
ISO 105-E01Textiles - Tests for colour fastness - Part E01: Colour fastness to water
ISO 105-E04Textiles - Tests for colour fastness - Part E04: Colour fastness to perspiration
ISO 105-X18Textiles - Tests for colour fastness - Part X18: Assessment of the potential to phenolic yellowing of materials
Other standards3
DIN 54310
ISO 5084Textiles - Determination of thickness of textiles and textile products
ISO 13934-1Textiles - Tensile properties of fabrics - Part 1: Determination of maximum force and elongation at maximum force using the strip method

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

1051.03

The scope document we hold says it was valid until 2026-04-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 1051.03

LineMethodMatrixRange
1ASTM D4966; Satra TM-31; AATCC 79; QAP 2017; DIN 54310; ASTM D3882; TL 703-97; AATCC 179; ASTM D6797; D3786; AATCC 8; NALTM 2100; AATCC 163; AATCC 61-2A; ISO 105-C06; AATCC 15; ISO 105-E04; AATCC 107; ISO 105-E01; ASTM D1776; ESD-ANSI; STM 2.1; ASTM D2594; D4964; D5034; TL 251-95; GMW3010; DIN-EN-ISO 13934-1; Nike IHM REV A; ISO/IEC 17025:2017automotive & textile fabrics-
2ASTM D3776; FMVSS-302; NFPA-701SS (Method 1); 19 Code of California Regulations 1237.1; SAE J369; AATCC 81; ISO 105-X18; ASTM D3512; AATCC 135; TL 600-93; BS8479; ASTM D1388 (Option A); TL-606-94; ASTM D5170; ASTM D5169; ASTM D6614; QTM 107; QTM 108; ASTM D2261; ASTM D5587; ASTM D5034; TL 105-93; ASTM D5035; ASTM D1777; ISO 5084; QAP 2037; ASTM D8007--
3AATCC 22; ASTM D3774; TM-5210-V1.0Fabric-
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited GUILFORD PERFORMANCE TEXTILES - PINE GROVE Pine Grove, PA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 24th day of July 2024. ____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1051.03 Valid to April 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1 Penn Dye Street, Pine Grove, PA, 17963, US

40.54842, -76.38468

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.