Accredited standards
68
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 68 standard numbers and the 28 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI34
ETSI EN 300 086-1
ETSI EN 300 086-2
ETSI EN 300 113-1
ETSI EN 300 113-2
ETSI EN 300 219-1
ETSI EN 300 219-2
ETSI EN 300 296-1
ETSI EN 300 296-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 394-1
ETSI EN 300 440
ETSI EN 300 676-1
Show all 34
ETSI EN 300 676-2
ETSI EN 300 720-1
ETSI EN 300 720-2
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-7
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-22
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 302 561
ETSI EN 303 035-1
ETSI EN 303 035-2
ETSI EN 303 405
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 758
IEC 61000 series12
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

Certificate says EN 61000-4-2. Probably the same standard; not checked against the EN document.

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity testExclusion

Limits written next to it

EN 61000-4-8:2010 (excluding short duration mode)

Exclusion. Written next to it on line 3 of A2LA certificate 2518.08.

IEC 61000-4-8 (excluding short duration mode)

Exclusion. Written next to it on line 3 of A2LA certificate 2518.08.

IEC 61000-4-8:2009 (excluding short duration mode)

Exclusion. Written next to it on line 3 of A2LA certificate 2518.08.

Power Frequency Magnetic Field EN 61000-4-8 (excluding short duration mode)

Exclusion. Written next to it on line 3 of A2LA certificate 2518.08.

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC7
IEC 60068-2-75
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test resultsSome clauses

Limits written next to it

EN 60945:2002 (9.0, 10.0)

Some clauses. Written next to it on line 4 of A2LA certificate 2518.08.

IEC 62133-1
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62262
IEC 62281
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national

National versions in the same scope

AS/NZS 62368.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

EN6
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50155Railway applications - Rolling stock - Electronic equipmentSome clauses

Limits written next to it

EN 50155:2017 (5.1.3, 13.4.3, 13.4.9)

Some clauses. Written next to it on line 4 of A2LA certificate 2518.08.

EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
EN 50564
IEC 60695 series3
IEC 60695-2-10
IEC 60695-2-11
IEC 60695-11-5
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsExclusion

Limits written next to it

EN 55032:2015/A11:2020 (excluding home satellite receiving systems, broadcast receivers)

Exclusion. Written next to it on line 2 of A2LA certificate 2518.08.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

FCC PART 15Radio Frequency Devices
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines onlyExclusion

Limits written next to it

ISO 7637-2:2004 (Amendment 1) (excluding Pulses 5a and 5b)

Exclusion. Written next to it on line 3 of A2LA certificate 2518.08.

RSS-GEN

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

9 lines
A2LA

ISO/IEC 17025

Active

2518.08

The scope document we hold says it is valid until 2026-12-31.