Motorola Penang Advanced Communication
Motorola Solutions Malaysia Sdn Bhd (455657-H) Innoplex, Plot 2A, Medan Bayan Lepas, Penang, Malaysia, Penang, Malaysia
- Accredited standards
- 68
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 68 standard numbers and the 28 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI34
ETSI EN 300 086-1
ETSI EN 300 086-2
ETSI EN 300 113-1
ETSI EN 300 113-2
ETSI EN 300 219-1
ETSI EN 300 219-2
ETSI EN 300 296-1
ETSI EN 300 296-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 394-1
ETSI EN 300 440
ETSI EN 300 676-1
Show all 34
ETSI EN 300 676-2
ETSI EN 300 720-1
ETSI EN 300 720-2
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-7
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-22
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 302 561
ETSI EN 303 035-1
ETSI EN 303 035-2
ETSI EN 303 405
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 758
IEC 61000 series12
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity testExclusion
Limits written next to it
EN 61000-4-8:2010 (excluding short duration mode)
IEC 61000-4-8 (excluding short duration mode)
IEC 61000-4-8:2009 (excluding short duration mode)
Power Frequency Magnetic Field EN 61000-4-8 (excluding short duration mode)
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC7
IEC 60068-2-75
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test resultsSome clauses
Limits written next to it
EN 60945:2002 (9.0, 10.0)
IEC 62133-1
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62262
IEC 62281
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
EN6
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50155Railway applications - Rolling stock - Electronic equipmentSome clauses
Limits written next to it
EN 50155:2017 (5.1.3, 13.4.3, 13.4.9)
EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
EN 50564
IEC 60695 series3
IEC 60695-2-10
IEC 60695-2-11
IEC 60695-11-5
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsExclusion
Limits written next to it
EN 55032:2015/A11:2020 (excluding home satellite receiving systems, broadcast receivers)
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
FCC PART 15Radio Frequency Devices
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines onlyExclusion
Limits written next to it
ISO 7637-2:2004 (Amendment 1) (excluding Pulses 5a and 5b)
RSS-GEN
EN 300 086-1; EN 300 086-1 v1.4.1; EN 300 086-2; EN 300 086-2 v1.3.1; EN 300 086; EN 300 086 v2.1.2; EN 300 113-1; EN 300 113-1 v1.7.1; EN 300 113-2; EN 300 113-2 v1.5.1; EN 300 113; EN 300 113 v2.2.1; EN 300 219-1; EN 300 219-1 v1.2.1; EN 300 219-2; EN 300 219-2 v1.1.1; EN 300 219; EN 300 219 v2.1.1; EN 303 035-1 v1.2.1; EN 303 035-2 v1.2.2; EN 300 394-1 v2.3.1; EN 300 394-1 v2.4.1; EN 300 328; EN 300 328 v2.2.2; EN 302 561; EN 302 561 v2.1.1; EN 303 758; EN 303 758 V1.1.1; AS/NZS 4295; AS/NZS 4295: 2015; EN 300 296-1; EN 300 296-1 v1.4.1; EN 300 296-2; EN 300 296-2 v1.4.1; EN 300 296; EN 300 296 v2.1.1; EN 301 893; EN 301 893 v2.1.1; EN 300 440; EN 300 440 v2.1.1; AS/NZS 4268; AS/NZS 4268:2017; ANSI/TIA-102.CAAA-E; ANSI/TIA-102.CCAA-B; ANSI/TIA-102.CAAB-D; ANSI/TIA-102.CCAB-A; ISO/IEC 17025:2017
EN 301 511; EN 301 511 v12.5.1; EN 301 908-2; EN 301 908-2 v13.1.1; EN 303 413; EN 303 413 v1.2.1; EN 301 908-13; EN 301 908-13 v13.2.1; EN 300 720-1; EN 300 720-1 v1.3.2; EN 300 720-2; EN 300 720-2 v1.2.1; EN 300 720; EN 300 720 v2.1.1; 3GPP TS 36.521-1; 3GPP TS 36.521-3; 3GPP TS 36.523-1; 3GPP TS 34.121-1; 3GPP TS 51.010-1; RSE 3GPP TS34.124; RSE 3GPP TS36.124; PTCRB PVG.04 Radiated Spurious Emissions (excluding TS 38.124); GCF-CC; PTCRB-NAPRD.03; PTCRB-PPMD; AS/NZS 4365; AS/NZS 4365:2011; EN 303 405 (Analogue); EN 303 405 v1.1.1 (Analogue); EN 300 676-1; EN 300 676-1 v1.5.2; EN 300 676-2; EN 300 676-2 v2.1.1; CISPR 32 (excluding equipment within the scope of CISPR 13); EN 55032:2015/A11:2020 (excluding home satellite receiving systems, broadcast receivers); ICES-003; ICES-003 (Issue 7); EN 301 908-1; EN 301 908-1 v13.1.1; EN 61000-6-4; EN 61000-6-4:2007/A1:2011; EN 61000-6-3; EN 61000-6-3:2007/A1:2011/AC:2012; CFR 47, FCC Part 15B (using ANSI C63.4:2014); CISPR 25:2002; EN IEC 61000-3-2; EN IEC 61000-3-2:2019; EN IEC 61000-3-2:2019/A1:2021; EN IEC 61000-3-2:2019/A1:2024; EN 61000-3-2:2014; IEC 61000-3-2; IEC 61000-3-2:2018; IEC 61000-3-2:2014; EN 61000-3-3; EN 61000-3-3:2013; EN 61000-3-3:2013/A1:2019; EN 61000-3-3:2013/A1:2021; IEC 61000-3-3; IEC 61000-3-3:2013
EN 301 489-1; EN 301 489-1 v2.2.3; EN 301 489-17; EN 301 489-17 v3.1.1; EN 301 489-5; EN 301 489-5 v2.2.1; EN 301 489-7; EN 301 489-7 v1.3.1; EN 301 489-3; EN 301 489-3 v2.3.2; EN 301 489-19; EN 301 489-19 v2.2.1; EN 301 489-22; EN 301 489-22 v2.1.1; EN 301 489-52; EN 301 489-52 v1.3.1; EN 50498; EN 50498:2010; EN 50121-3-2; EN 50121-3-2:2016/AC:2008; EN 50121-3-2:2016/A1:2019; EN 50155; EN 50155:2017 (5.1.3, 13.4.3, 13.4.9); EN 50121-4; EN 50121-4:2016; EN 50121-4:2016/A1:2019; EN 60945; EN 60945:2002 (9.0, 10.0); EN 55035; EN 55035:2017/A11:2020; EN 61000-6-1; EN 61000-6-1:2007; EN 50130-4; EN 50130-4:2011; IEC 60695-2-11; IEC 60695-2-11:2014 Edition 2.0; IEC 60695-2-11 Edition 1.0 2000-10; IEC 60695-2-10; IEC 60695-2-10:2013 Edition 2.0; IEC 60695-2-10 Edition 1.0 2000-10; IEC 60695-11-5; IEC 60695-11-5:2016 Edition 2.0; IEC 60695-11-5 Edition 1.0 2004-12; AS/NZS 60950.1; AS/NZS 60950.1:2015; EN 62368-1; EN 62368-1:2014+A11:2017; EN 62368-1:2014+AC:2015+A11:2017; IEC 62368-1; IEC 62368-1:2014; EN 62368-1:2020+A11:2020; IEC 62368-1 Edition 3.0 2018; EN 62368-1:2024+A11:2024; IEC 62368-1:2023, Edition 4; AS/NZS 62368.1; AS/NZS 62368.1:2018; AS/NZS 62368.1:2022
EN 61000-4-2; EN 61000-4-2:2009; IEC 61000-4-2; IEC 61000-4-2:2008; EN 61000-4-3; EN 61000-4-3:2020; EN 61000-4-3:2006; IEC 61000-4-3:2020; IEC 61000-4-3; IEC 61000-4-3:2006; EN 61000-4-4; EN 61000-4-4:2012; IEC 61000-4-4; IEC 61000-4-4:2012; EN 61000-4-5; EN 61000-4-5:2014/A1:2017; IEC 61000-4-5:2014/A1:2017; EN 61000-4-6; EN 61000-4-6:2014/AC: 2015; EN IEC 61000-4-6:2023; IEC 61000-4-6; EN 61000-4-6:2013/COR1:2015; EN 61000-4-11; EN 61000-4-11:2020/AC:2022; EN 61000-4-11:2004/A1:2017; IEC 61000-4-11; IEC 61000-4-11:2020/COR2:2022; IEC 61000-4-11:2004/A1:2017; ISO 7637-2:2004; EN 61000-4-8; EN 61000-4-8:2010; IEC 61000-4-8; IEC 61000-4-8:2009
IEC 62262; IEC 62262:2002; IEC 62262:2002+AMD1:2021; EN 62262; EN 62262:2002; EN 62262:2002+A1:2021; IEC 60068-2-75; IEC 60068-2-75:2014; IEC 60068-2-75:1997; EN 60068-2-75; EN 60068-2-75:2014; EN 60068-2-75:1997; CTIA Test Plan for Wireless Device over the Air Performance; TS 37.544; TS 37.544 v14.3.0; RSS-Gen; RSS-119; RSS-130; RSS-132; RSS-133; RSS-134; RSS-139; RSS-140; RSS-141; RSS-182; RSS-192; RSS-195; RSS-198; RSS-199; RSS-210; RSS-247; RSS-248; HKCA 1002, Issue 6; HKCA 1010, Issue 1; HKCA 1047, Issue 2; ANSI C63.4-2014; CFR 47, FCC Part 15C; ANSI C63.10:2020+Cor.1-2023; ANSI C63.10:2020+Cor.1-2023+C63.10a-2024+Errata to C63.10a-2024; CFR 47, FCC Parts 22; CFR 47, FCC Parts 24; CFR 47, FCC Parts 25; CFR 47, FCC Parts 27; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26-2015; CFR 47, FCC Parts 90; CFR 47, FCC Parts 95; CFR 47, FCC Parts 97; CFR 47, FCC Parts 101; CFR 47, FCC Parts 73; CFR 47, FCC Parts 74
United Nations Document ST/SG/AC.10/11 (Section 38.3); United Nations Document ST/SG/AC.10/11 (Section 38.3) Revision 7; United Nations Document ST/SG/AC.10/11 (Section 38.3) Revision 7, Amendment 1; United Nations Document ST/SG/AC.10/11 (Section 38.3) Revision 8; IEC 62281; IEC 62281 Edition 4.0 2019; IATA Lithium Battery Shipping Guideline 8th Edition (Section 6.3); IATA Lithium Battery Shipping Regulations 9th Edition (Section 6.3); IATA Lithium Battery Shipping Guideline (Section 6.3); IATA Lithium Battery Shipping Regulations 10th Edition (Section 6.3); IATA Lithium Battery Shipping Regulations (LBSR) 11th Edition; IATA Battery Shipping Regulations; IATA Battery Shipping Refulations (BST) 12th Edition; IEC 62281:2019+A1:2021; IEC 62281:2019+AMD1:2021+AMD2:2023; 10 CFR Section 430.23 (aa), Appendix Y to Subpart B of Part 430; 10 CFR Section 430.23 (aa), Appendix Y to Subpart B of Part 430 (January 1, 2022); 10 CFR Section 430.23 (aa), Appendix Y to Subpart B of Part 430 (January 1, 2023); 10 CFR Section 430.23 (aa), Appendix Y to Subpart B of Part 430 (January 1, 2024); CAN/CSA-C381.2-17; EN 50564; EN 50564: 2011; IEC 62133-1; IEC 62133-1:2017; IEC 62133-2; IEC 62133-2:2017; IEC 62133-2:2017/AMD1:2021; IEC 62133:2012; EN 62133-1; EN 62133-1:2017; EN 62133-2; EN 62133-2:2017; BS EN 62133-2:2017+A1:2021; JIS C 8714:2007; JIS C 8712:2015; J62133-2; J62133-2:2021); Appendix 9 (Japan Standard); KC 62133-2; GOST R IEC 62133-1:2019; GOST R IEC 62133-2:2019
ANSI C63.4:2014; ANSI C63.10:2013; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; ANSI/TIA-603; ANSI C63.26-2015
CFR 47, FCC Parts 80; 87 (using ANSI/TIA-603-E; ANSI C63.26-2015); CFR 47, FCC Part 15E (using ANSI C63.10:2013); ANSI C63.10:2020+Cor.1-2023; ANSI C63.10:2020+Cor.1-2023+C63.10a-2024+Errata to C63.10a-2024
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
9 lines
ISO/IEC 17025
Active2518.08
The scope document we hold says it is valid until 2026-12-31.
Location
Motorola Solutions Malaysia Sdn Bhd (455657-H) Innoplex, Plot 2A, Medan Bayan Lepas, Penang, Malaysia, Penang, MY
5.40650, 100.25591
Open in MapsLabs with overlapping accredited scope in Malaysia
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.